Wanted Electrosurgical Unit Parts - Buying Leads
Welcome to MedWOW’s Electrosurgical Unit Buying Leads section!This section contains thousands of Electrosurgical Unit Buying Leads, featuring: complete systems, parts and medical supplies - all of which can be filtered by category, device, manufacturer, model, and location. All of MedWOW’s Electrosurgical Unit Buying Leads are pre-qualified buyers who know exactly what they are looking for and are committed to purchase immediately. More than 10,500 visitors enter the MedWOW site daily and transactions occur quickly and on a regular basis, so Electrosurgical Unit leads are kept fresh and current. When you take advantage of MedWOW’s Electrosurgical Unit Buying Leads, you will meet new international customers who will quickly become part of your regular customers.
Read more about wanted medical equipment leads | ![]() |
- Complete Systems (16)
- Parts (1)
Lead Details
Buyer details
Unit max. price (USD)
Quantity
Device: Electrosurgical Unit
Manufacturer: Valleylab
Model: LigaSure
Name / Number: Dual Foot Pedal / IPX8
Manufacturer: Valleylab
Model: LigaSure
Name / Number: Dual Foot Pedal / IPX8
Location: United States, California
Negotiable
1
Electrosurgical Unit may also be referred to as :
Endometrial Ablation System | ESU | Hyfrecator | Malis Coagulator | Surgical Diathermy | Surgical Unit | Electrosurgical Unit, Argon-Enhanced Coagulation | Electrosurgical Unit, General Purpose | Electrosurgical Generator | Electrosurgery Unit | Electrosurgery Generator | Diathermy Unit, Surgical | Diathermy Unit | Coagulator, Electrosurgical | BovieTips for buying Electrosurgical Unit Parts
-
These units should come with a solid-state generator, with a typical frequency range of 0.3 to 1 MHz. They should have an isolated monopolar output, a hand switch, a footswitch, and bipolar output.
-
The output power for monopolar cutting should not exceed 300 W, and the open circuit voltage should not exceed 2,000 peak-to-peak volts; these values apply in general-purpose use.
-
For coagulation, the output and open circuit voltage should not exceed 120 W and 6,000 peak-to-peak volts, respectively. Bipolar mode should use no more than 50 W and 300 peak-to-peak volts.
-
Units should include the following: a return electrode contact quality monitor, independent output, visual and audible activation indicators, alarm capable of volumes higher than 45 dB at one meter, power-setting display and convection or fan cooling system.
-
Argon-enhanced units should have a flow range of 0 to 10 L/min, a tank capacity of more than 1,200 L (42 ft3), and a low-pressure alarm; the device should include an alarm capable of volumes higher than 45 dB at one meter.
-
There are numerous designs of electrosurgical units, and facilities should base their comparisons among devices according to characteristics, usefulness of features, safety, and reliability - all of these affect clinical performance.
-
Users who are considering which argon-enhanced coagulation system to purchase, should determine whether they wish to expand their current electrosurgical system with a compatible argon module or they get a new one with an integral argon unit.