Help
Services: Requests: Additional Features: |
Neurosurgery
Flexible endoscopic device designed for viewing blood vessels.
Flexible endoscope intended for viewing blood vessels, usually used by surgeons for operations inside the vessels. ![]()
Electrosurgical units capable of delivering argon gas for coagulation purposes.
Argon gas delivery systems on mobile carts. These units can be connected to electrosurgical units that perform both monopolar and bipolar (without use of argon) functions. Gas and electric current can be delivered simultaneously. Argon enhanced electrosurgical units are used for coagulation of large surfaces, in a rapid and uniform manner. ![]()
A system which determines the reaction of the autonomic system to stimulations.
A system which determines the reaction of the autonomic system to stimulations. The stimulation effect is achieved by selected activities of the patient which result in variations of the heart rate. ![]()
Various devices and equipment based on electrical measurements, which are performed with the aid of surface electrodes or volume electrodes.
This is a large group of equipement for very different usages, such as: measuring the body impedance for recording the respiratory activity, or the measurement of the impedance of human sweat, or performing impedance imaging of the breast etc. ![]()
Units designed for warming blood products and IV solutions.
Units for warming blood products and IV solutions before infusion, using a heat exchanger. Usually they are attached to the IV pole. Some are used for irrigation solutions used in endoscopies. ![]()
The Electrocautery units are used to stop bleeding by means of heat.
The Line-Powered Electrocautery Units are used for the electro cauterization (or electrocautery) in surgery to burn and seal blood vessels to stop bleeding, and to remove unwanted or harmful tissue. The electro cauterization is achieved by using a small probe with a heated tip, or a tip that uses an electric current running through it, to burn or destroy the tissue. ![]()
A device which measures changes in oxygen levels beneath the sensor in order to protect the brain and vital organ areas from hypoxia.
A device which measures changes in oxygen levels beneath the sensor in order to protect the brain and vital organ areas from hypoxia. ![]()
Diagnostic and Treatment equipment which can be used in the chiropractic practice.
![]()
A machine which allows teleradiotherapy with a Cobalt 60 source.
The cobalt machine consists of a heavy gantry with an arm ended by a heavy shielded container. Inside the container there is a high intensity cobalt source. The shutter at the front of the head can be either opened or closed to allow the radiation treatment. The system is very accurate and stable which allows precise for radiotherapy ![]()
A device for compression fractures management.
A device for compression fracture management. This category of equipment includes various apparatus and gadgets which can assist the physician during the treatment of vertebrae. ![]()
Image-guided systems used for stereotactic surgical procedures and preoperative information.
A system used for image-guided surgery, for stereotactic surgical procedures such as frameless cranial and spinal neurosurgery, endoscopic sinus surgery, and orthopedic surgery. The image-guided surgery system uses diagnostic imaging modalities (CT, MRI) together with localization/digitization techniques. Surgeons view displayed images of the system`s probe in relation to patient anatomy, for preoperative surgery planning, and for interactive guidance during surgery. ![]()
A system which is intended to set various operating devices in the pre-selected default parameters.
A system which is intended to set various operating devices in the pre-selected default parameters. The assumption is that the operating room equipment is used by several surgeons, each of whom has his own preferences regarding the settings of the different equipment units. By using a personal key (e.g. smart card, disk-on-key, password) the control system recognizes the surgeon and automatically pre-sets the equipment into the preferred settings. ![]()
Orthoses used to correct some head deformities of the head, like positional plagiocephaly. Often composed of polypropylene, styrene, or polyethylene foam formed in the shape of a headband or helmet, which apply gentle pressure to the most protuberant areas of the patient`s skull
Head orthoses are used to correct deformities in infants and young children that are not related to premature bone union (i.e., nonsynostotic deformations) such as asymmetries in the cranial vault, skullbase, and face ![]()
A temperature isolated container which is intended to keep liquid cryogenic gas and to avoid its rapid evaporation.
A temperature isolated container which is intended to keep liquid cryogenic gas and to avoid its rapid evaporation. ![]()
Containers to store tissues and biological materials such as skin, bone etc
Containers which are kept at low temperatures by the aid of Nitrogen or other cryogenic liquid and are used to store for long periods tissues, such as skin and bones and various biological materials. ![]()
Digital cameras which can be inserted over the eye piece or instead of it, and produce high quality digital images.
The camera replaces the human eye and enables an electronic standard image of medical observations, such as microscopy, operational microscopy, endoscopy, ophthalmology etc. ![]()
Graphic recording of brain electrical activity.
A device which transmits electric signals from brain onto a recorder which reproduces their characteristics on an electroencephalogram. Can be used for localizing tumors or lesions on or near brain surface, also for studying various neurological conditions, and to assist in evaluating psychiatric disorders. ![]()
Various electrical devices, such as mattresses or blankets, intended for direct fast heating of the patient.
Usually, an electrical heating element is embedded in a flexible sheet, carefully protected from over heating by reliable thermostat systems. ![]()
An appliance which tests the applied electrodes used in various diagnostic procedures such as EEG, ECG, EMG, ENG and evoked potentials.
Most testers are capable of measuring, besides the basic characteristic, also the interference voltages that may be stored on electrodes and/or detecting faulty lead wires or cables, or measure the impedance of the leads and cables from the electrodes to the measuring unit. ![]()
Monopolar and bipolar electrosurgical devices.
Monopolar and bipolar units for electrosurgery. In monopolar units an active cable and electrode is used to deliver a high-frequency current to the patient, which returns to the unit using a dispersive electrode. In bipolar units the two tips of forceps or scissors are used as the active and dispersive leads. Bipolar electrosurgery is mainly used for coagulation of fine tissue . ![]()
Classic EMG units, and equipment for testing the evoked potential response.
EMG equipment is used to assess muscular function, nerve conduction and reflexes. EP equipment measures and records electrical signals from brain in response to audio, visual, or somatosensory stimuli. This information is used together with other clinical information to assess brain sensory functions. Modern equipment is usually designed for both tasks. ![]()
Fiberoptic light sources for endoscopes.
Fiberoptic light sources for endoscopes (flexible or rigid) in diagnostic, observation, and surgical procedures. High and low intensity fiberoptic light is used for viewing surgical fields and body cavities, while minimizing tissue heating. These lighting sources are smaller and more cost-effective as opposed to incorporating a light source in each fiberoptic instrument. ![]()
Stereotactic systems for radiosurgery using gamma radiation sources.
Stereotactic systems for setting exact coordinates in radiosurgery using gamma radiation sources. ![]()
A system which includes a high-frequency generator driving a hand-piece with a vibrating knife, for tissue cutting and coagulation in surgery.
A system which includes a high-frequency generator driving a hand-piece with a vibrating knife, for tissue cutting and coagulation in surgery. This surgical unit uses ultrasound energy with it`s heating effect to cut and coagulate targeted tissue allowing for proper hemostasis with no significant damage to vessels up to 3 millimeters in diameter. This definition relates to complete systems or separate generators and separate knife hand-pieces. ![]()
Units for heating or cooling of the body or of a localized area.
A machine which circulates warm or cold fluid (e.g. water) through a special mattress, blanket or pads. The temperature and the flow of the fluid is electronically monitored and controlled, to keep the body temperature in a preset range. Safety foolproof measures are embedded in the system. ![]()
A monitor for monitoring and recording the intra cranial pressure.
A monitor which is connected to a special intra cranial pressure transducer and provides real time monitoring of the intra cranial pressure. ![]()
A device which is intended for Intradiscal Electrothermal Therapy.
A device which is intended for Intradiscal Electrothermal Therapy, by means of RF heating applied via an intradiscal electrode. The source of the RF is a special generator, either CW or pulsed energy. ![]()
Carbon dioxide lasers for use in general surgery and dermatology.
Surgical carbon dioxide lasers are used in microscopic surgery,macroscopic surgery, endoscopic and laparoscopic procedures, as well as in general surgery and dermatology. They are used to make surgical incisions, to cut and vaporize deeper tissues, and for coagulation of small vessels. ![]()
Surgical Nd:YAG lasers for laparoscopic and endoscopic procedures.
Lasers that are mainly used for cutting, excising, vaporizing, and coagulation of deep tissue. The laser energy of the Nd:YAG penetrates and is absorbed into a large body of deep tissue. This leads to photocoagulation of blood vessels at low power densities, and vaporization of tumors at high power. ![]()
Solid-state Ho:YAG lasers with the doping element HO.
HO:YAG lasers emit energy near the absorption peak of water, so they can cut or ablate tissue with moderate hemostasis, minimal charring, and a thin zone of necrosis. These lasers belong to a group of solid-state lasers containing the doping element HO. They are used in hospitals and outpatient facilities for various surgical applications. ![]()
Laser blood flowmeters using Doppler principle from laser source.
Flowmeters which transmit light through fiberoptic lighting probe, illuminating the tissue being tested. The frequency shift of the light that reflects back from the tissue is a measure of the blood flow (Doppler effect). Laser flowmeters are often used during surgery and endoscopic procedures to accurately measure perfusion in the superficial tissue. ![]()
Linear accelerator units for X-ray and electron radiotherapy.
Linear accelerator is an electronic device which converts microwave energy into high energy electrons and photons. Range of energies will be generally between 4-22 MeV. The geometrical structure is very stable and precise to allow high precision treatment. The two main parts are the gantry with the radiation source and the special coach for patient placement. ![]()
A binocular add-on magnifying loupes which are attached to the personal glasses and provide magnification.
A binocular add-on magnifying loupes which are attached to the personal glasses and provide magnification. ![]()
Operating microscopes for high magnification in surgery.
Operating microscopes used for magnifying miniscule structures during surgical procedures, when high magnification and adjustable focusing is required, when a loupe isn`t sufficient. Surgeons can use a loupe, with a single lens for each eye and is attached to glasses or a headband, but focal length of the loupe cannot be adjusted. ![]()
Motorized viewboxes for loading X-ray sequence.
View boxes that electronically load X-rays in a predetermined sequence. Generally used to minimize examination time, also for presentations and consultations. ![]()
A small diameter short endoscope for neurological observations and operations, including the introduction of micro electrodes.
A small diameter short endoscope for neurological observations and operations, including the introduction of micro electrodes. ![]()
General purpose operating tables with adjustable segments.
Tables used during surgical procedures. Patient`s body has full support with minimum manipulation. Divided segments for head,body, and legs, as well as table height, can be adjusted manually or using hydraulic systems. ![]()
A device with a tip which can be heated to a preset temperature range for producing coagulation in ophthalmologic use.
The heater is a tiny element with a very small contact area. Otherwise it is similar to the cautery equipment which is generally used. ![]()
A device which enables inspection of the eye without dilatation of the pupils. It contains the optical system and a proper light source.
A simple optical system which enables observation of the surface of the eye, and the internal parts of the eye, without dilatation of the pupil. Such a system has variable magnification capabilities and enables to view large angles inside the eye. A special illuminating device is built in to the system and it usually produces a defused light which provides clear intraocular view. It can be hand held or head mounted. ![]()
Examination and/or treatment tables with adjustable orthopedic accessories.
Orthopedic tables with individual adjustable parts for examination and treatment. Various support and traction accessories may be included. ![]()
PACS (Picture Archiving and Communication System) for collecting, storing and retrieving patient images and data.
Computer-based systems (PACS) that can collect, store, archive and retrieve images and data in digital format from single or multiple modalities (CT, MRI, US, CR, DR, nuclear medicine, etc). These systems are used in medical centers in conjunction with the HIS and RIS and serves as a major tool for clinical routine work. These systems enable telemedicine consultations. ![]()
A device which control pain by neurostimulation.
A device which control pain by neurostimulation. ![]()
A device for warming patients by a warmed airflow or electric pads.
The warmed air is forced to flow by a fan through a blanket. The system is electronically controlled to maintain the patient`s body temperature. ![]()
Data management information systems for physician`s office and clinics.
A system used by healthcare providers in private or group medical clinics or organizations. These systems have the appropriate hardware and software for patient record keeping and diagnosis, and for administrative tasks such as inventory, billing, and scheduling. ![]()
Eyeware used for protection during laser procedures.
Eyeware with filter glass used during laser procedures. Laser wavelength can be specified to offer adequate protection. ![]()
Devices used to analyze the spectrum of bioelectrical or medical device signals, and characterize EMI - electromagnetic interference - coming from other equipment or natural sources.
These analog or digital devices can be used to examine the spectral composition of electrical, acoustic, optical waveform, or the power spectrum. The anlayzers display and measure amplitudes of the sinusoidal components of a signal, as a function of frequency. ![]()
A headframe attached to skull for stereotactic use during surgery.
A unit used for neurosurgical or radiosurgical procedures, with adaptors for various imaging systems (CT, MRI and others). A head ring with fixating pins is attached to the skull. The precise area of the brain that is targeted can be localized. Target coordiantes can be set using information from CT, MRI. etc. ![]()
Linear accelerator based stereotactic systems for radiosurgery.
Stereotactic system for radiosurgery, used to accurately direct the electromagnetic ray produced by a radiation source, like a linear accelerator. ![]()
Containers used to pack, sterilize and store surgical instruments for re-use.
Containers used during the sterilization process. Sealed perforated boxes allow sterilizing agent to flow through, and filters for bacteria control sterility of contents. These containers are also used for post- sterilization and pre-use storage. ![]()
Photo or cine cameras used during surgery.
Cameras that are used during surgery for documentation purposes. They can be either photo or cine cameras, some with a flash and sterile covering. ![]()
A device which can be attached to the operator`s head for illuminating the operating site.
A device which can be attached to the operator`s head for illuminating the operating site. The light source can be a nearby high power lamp (etc.) which is connected to the harness by a fiber optic conductor or an integrated lamp or LED device which is mounted on the harness. ![]()
A variety of tools which serve the surgeons while operating.
A variety of tools which serve the surgeons while operating. Most tools are specially designed for the specific procedure or operation. ![]()
Surgical lamps for use in the OR (operating lights).
Operating room lights, to illuminate the surgical site with minimal color distortion, and to reduce shadow effect. They optimize visualization of small objects at different depths, or through small incisions. ![]()
Pneumatic and electrically powered surgical handpieces, and other tools.
A wide variety of surgical handpieces and accessories that are used in operative procedures involving bone and cartilage dissection. These pneumatic or electrically powered handpieces are used for dissecting, drilling, curetting, abrading, sculpting, and sawing. They are also used on materials used in implanted prostheses. Bone mills produce the material used for bone regeneration in bone grafting and joint reconstruction. ![]()
Smoke evacuation systems for use during various surgical procedures.
Smoke evacuation systems are suitable for use during various surgical procedures, to capture smoke which may contain potentially hazardous materials. The smoke plume that is not evacuated can release airborne particles which can be inhaled by the surgical team causing unwanted side effects. ![]()
Cautery units for electrothermal coagulation and tissue destruction.
Device for control of bleeding and for therapeutic purposes. An electrically heated probe is used for coagulation or to destroy tissues. These devices can be line or battery powered. A high-resistance wire is attached to the probe tip, which is connected to the power source. Heat is delivered to the tissue through a percutaneously inserted catheter with a heating device on it`s tip. The unit itself controls the energy delivered via the catheter. Different probes are included for different applications. ![]()
A system intended for fragmentation, lysing and removal of the occluding substances in the arteries.
A system intended for fragmentation, lysing and removal of the occluding substances in the arteries. Lysing process can be achieved either by chemical methods, by applying lysing material (like Heparin) directly to the thrombus, or by using a physical means e.g. Ultrasound, High Pressure jet, Radiation etc. ![]()
Ultrasonic blood flowmeters, also assisting in assessment of flow restrictions.
Ultrasonic blood flowmeters used to locate and assess flow restrictions.The flowmeters use a radio frequency unit with ultrasonic transducer probe, and audio/visual indicator. Blood velocity can be measured invasively or non-invasively, using either continuous-wave or pulse-Doppler techniques. ![]()
These Intra-operative Ultrasound (IOU) Systems are specially design to utilized a small hand held transducers to be used during surgery.
The Intra-operative Ultrasound (IOU) Systems are surgery dedicated ultrasound systems, used for imaging, guidance and controlling purposes in the sterile environment of the operating theater during surgeries. The surgeon uses and controls the system and accesses the image and the additional information obtained and processed through the system while performing surgery. ![]()
A video system used during endoscopic procedures.
A video system used during endoscopic procedures for viewing, storing, and retrieving images. These systems are generally used in procedures using rigid and flexible endoscopes, for both diagnostic and therapeutic purposes. ![]()
A system intended for accepting voice commands and executing various standard functions in the operating room.
A system intended for accepting voice commands and executing various standard functions in the operating room. ![]()
Digital system for dictating and transcribing medical reports and records.
A language-linked system used for digital dictation. Physicians and medical personnel use this system to dictate, transcribe and review medical reports. For added efficiency, speech recognition software can directly transmit recorded data into a written format, for immediate editing. Most systems enable remote access, and management functions such as quality assurance and workflow tracking. Some can be used for voice-mail messages. ![]()
Warming devices for blankets and other items.
Cabinets for warming blankets, using hot air or steam circulation for heating. These units have a heating system with temperature controls and alarms that indicate overheating. Some units have other heating functions ( various solutions, bedpans) and can be used for different heating purposes within the hospital units. ![]() |