Manufacturer Specifications - Modulus CD, Ohmeda (GE Healthcare)

Please note: None of the equipment posted for sale on MedWOW.com is owned by MedWOW, should you have any questions regarding a specific item, please direct them to the appropriate seller by making use of the available communication channels on the items page.
MODEL

Modulus CD

GAS CYLINDER HOLDER (PHYSICAL CHARACTERISTICS)4(O2, N2O, air, opt CO2 or heliox)
BACKUP BATTERYUPS; min system func
KindGel cell
Use per charge, hrSee footnote *
Service contractYes
YEAR 2000 COMPLIANTYes **
SUCTION DEVICE (MONITORS)Optional
GAS EVACUATION SYSTEM (PHYSICAL CHARACTERISTICS)Active or passive
VAPORIZERS
Agents (DISINFECTION/STERILIZATION)Sevoflurane, enflur-
KindSee footnote ***
Number (STAINING POSTS)3
InterlockYes
POWER NEEDED, VAC (MONITORS)100/120; optional
OUTLETS FOR AUXILIARY DEVICES (RISE TIME, msec)4
AUTOMATIC VENTILATOR (PHYSICAL CHARACTERISTICS)Various modelsModel 7850
BELLOWS (PHYSICAL CHARACTERISTICS)Yes
Size (STIMULATOR)1,500mL
KindAscending (standing) † 
Primary controls
Ventilation methods (PHYSICAL CHARACTERISTICS)Volume control
Tidal volume (MONITORED PARAMETERS)Yes
Range, cc (PHYSICAL CHARACTERISTICS)50-1,500
Frequency, bpm (PHYSICAL CHARACTERISTICS)2-100
Inspiratory flow,
L/min (WATER REQUIREMENTS,)10-100
Inspiratory pause25%Ti
Pressure-limit,
cm H2O (Pressure range,)20-100 adjustable
Peep, cm h2o (CONTROLS)0-20, optional
Other controls (PHYSICAL CHARACTERISTICS)Float-type flowmeter
System checks (PHYSICAL CHARACTERISTICS)Manual pre-use test,
ANESTHESIA DATA MANAGEMENT (PHYSICAL CHARACTERISTICS)Standard disk drive, RS232 output
PHYSICAL CHARACTERISTICS
H x W x D, cm (in)158x 94 x 71
WEIGHT, kg (lb) (DISPLAY)210(463.1)
Shelves, cm (PHYSICAL CHARACTERISTICS)92.7x 38 (1);
Drawers, cm (PHYSICAL CHARACTERISTICS)36x 38 x 10.1 (2);
INSTALLATIONMobile with locking
Oxygen concentration (MONITORS)Yes
Oxygen sensor type (MONITORS)Fuel cell
RESPONSE TIME, sec (SCATTERED LIGHT)<35
Co2 concentration (DISPLAY)Yes
Apnea alarm (MONITORS)Yes ***
N2o (Interference compensation)Yes
Anesthetic agent monitors (MONITORS)Yes
Anesthetic agents (MONITORS)Sevoflurane, enflur-
Auto id (MONITORS)Optional
Agent conc alarm (MONITORS)Yes
Ecg (PARAMETERS)Optional
Heart rate (DISPLAYS)Optional
St segment (CENTRAL STATION)Optional
Noninvasive bp (MONITORS)Optional
Invasive bp (MONITORS)Optional
TEMPERATUREOptional
Pulse oximeter (MONITORS)Yes
Other features (MANAGEMENT FUNCTIONS)Alarm management
Monitors (CONTROL PANEL)
Airway pressure alert (MONITORS)Yes
Where measured (MONITORS)Inspiratory limb
Over-pressure alarm (MONITORS)Yes - no range specified.
Subatmospheric
PRESSURE ALARMYes
Continuing press alarm (MONITORS)Yes
Low pressure/apnea (MONITORS)Yes
Expiration vol/flow (MONITORS)Yes
Oxygen sensor type (MONITORS)Vane
Where measured (MONITORS)Expiratory port
Rate alarm (MONITORS)Yes
Apnea alarm (MONITORS)Yes
Reverse flow alarm (Subatmospheric)Yes
High/low min vol (MONITORS)Yes
High/low flow (MONITORS)Yes
PRIORITIZED ALARMS (PHYSICAL CHARACTERISTICS)Yes
DISPLAYS (STAINING POSTS)Yes
Number (STAINING POSTS)2
KindHigh-resolution CRT
Integrated (PHYSICAL CHARACTERISTICS)Yes
Interface w/others (PHYSICAL CHARACTERISTICS)HP ACMS, Omnicare 24
OXYGEN ALARM (PHYSICAL CHARACTERISTICS)Pneumatic
DATA INPUTStandard disk drive
HYPOXIC MIXTURE ALARM (PHYSICAL CHARACTERISTICS)Mechanical limit
AUTO RECORD KEEPER (PHYSICAL CHARACTERISTICS)Case-save feature
GAS CONNECTIONS3 - for more inforamtion please see comments.3 (O2, N2O, air)
OTHER SPECIFICATIONS (AIR SUPPLY)Alert zones and
FDA CLEARANCE (Interference compensation)Yes
CE MARK (MDD) (Interference compensation)No
WHERE MARKETEDLatin America, USA
You may also be interested in the following Manufacturer Specifications:
Disclaimer

Information on this page may be partial or incomplete and may contain mistakes or inaccurate information.

MedWOW disclaims any obligation, responsibility or liability which concerns or relates to any information on this page.

Anesthesia Machine, Ohmeda (GE Healthcare), Modulus CD