MODEL

717

OPEN TEST MODES32
POWER NEEDED, VAC (ENERGY)115/220
CONFIGURATIONFloor
MAINTENANCE (WAVELENGTH, nm)4/year
DIMENSIONS (HXWXD) CM, (IN) (DISPLAY)152x 152 x 76 (60x 60 x 30)
WEIGHT, kg (lb) (DISPLAY)590 (1,300)
MAXIMUM RESULTS/HR750 with ISE
BASIC CHEMISTRIES
Albumin (BASIC/TIME, min)Yes
Alp (BASIC/TIME, min)Yes
Alt (BASIC/TIME, min)Yes
Amylase (SPECIAL/TIME, min)Yes
Ast (BASIC/TIME, min)Yes
Bun (BASIC/TIME, min)Yes
Ca+ (BASIC CHEMISTRIES)Yes
Cholesterol (BASIC/TIME, min)Yes
Ck (BASIC/TIME, min)Yes
Cl- (BASIC/TIME, min)Yes
Creatinine (BASIC/TIME, min)Yes
Direct and total bilirubin (BASIC/TIME, min)Yes
Glucose (ASSAYS)Yes
Inorgan phosphorus (BASIC/TIME, min)Yes
Iron (BASIC/TIME, min)Yes
K+ (BASIC/TIME, min)Yes
Ldh (BASIC/TIME, min)Yes
Na+ (BASIC/TIME, min)Yes
Total protein (BASIC/TIME, min)Yes
Triglycerides (BASIC/TIME, min)Yes
Uric acid (BASIC/TIME, min)Yes
Additional (Alarms, high/low)Bicarbonate, TIBC
AUTO CALIBRATION (WATER REQUIREMENTS, L/min)Yes
P-5-p (SPECIAL/TIME, min)Yes (serum)
T4 (SPECIAL/TIME, min)Yes
Tu (SPECIAL/TIME, min)Yes
Urine protein (SPECIAL/TIME, min)Yes
Additional (Alarms, high/low)Serum: CRP, lactate, LD-1, Mg, p-amylase, transferrin; urine: BUN, Ca+, creatinine, glucose, Mg, phosphorus, uric acid
OPTICAL SYSTEM (SPECIAL/TIME, min)See commentsPhotometric, colorimetric
SPECIAL CHEMISTRIES
Ethanol (SPECIAL/TIME, min)Yes (serum)
Aldolase (SPECIAL/TIME, min)Yes (serum)
Amylase (SPECIAL/TIME, min)Yes (urine)
C3 (SPECIAL/TIME, min)Yes (serum)
C4 (SPECIAL/TIME, min)Yes (serum)
Cholinesterase (SPECIAL/TIME, min)Yes (serum)
ABNORMAL VALUES FLAGYes
TEST METHODS (SAMPLE REQUIREMENTS)End point, ISE, kinetic
AUTO QUALITY CONTROL (SPECIAL/TIME, min)Yes
MAX. CAPACITY SAMPLE TRAY (SPECIAL/TIME, min)60; multiple trays can be programmed
REAGENT SUBSTITUTION (SPECIAL/TIME, min)Yes
DIRECT SAMPLING (DRUG ASSAY/TIME, min)Yes
ILLUMINATION SOURCETungsten-halogen
CALIBRATION FREQ (SAMPLE REQUIREMENTS)Test dependent
SAMPLE REQUIREMENTS
Serum and plasma (SAMPLE REQUIREMENTS)Yes
Urine (TESTING RANGE, MMOL/L)Yes
Csf (SAMPLE REQUIREMENTS)Yes
Ck-mb (SPECIAL/TIME, min)Yes (serum)
Csf protein (SPECIAL/TIME, min)Yes
Ggt (SPECIAL/TIME, min)Yes (serum)
Hdl cholesterol (SPECIAL/TIME, min)Yes (serum)
Iga (SPECIAL/TIME, min)Yes (serum)
Igg (SPECIAL/TIME, min)Yes (serum)
Igm (SPECIAL/TIME, min)Yes (serum)
REAGENT DELIVERY (SPECIAL/TIME, min)Automatic
REAGENT USEDLiquid
PROCESSOR INTERFACE (WATER REQUIREMENTS, L/min)RS232C
DISPLAYCRT, printer
AUTO DILUTION (PURCHASE INFORMATION)Yes
SAMPLE SIZE/RANGE µL (SAMPLE REQUIREMENTS)1-20
DRUG ASSAYS
Amphetamine (DRUG ASSAY/TIME, min)Yes
Barbiturate (DRUG ASSAY/TIME, min)Yes
Benzodiazepine (DRUG ASSAY/TIME, min)Yes
Cannabinoid (DRUG ASSAY/TIME, min)Yes
Cocaine metabolite (DRUG ASSAY/TIME, min)Yes
Digoxin (DRUG ASSAY/TIME, min)Yes
Ethanol (SPECIAL/TIME, min)Yes
Gentamicin (DRUG ASSAY/TIME, min)Yes
Methadone (DRUG ASSAY/TIME, min)Yes
Methaqualone (DRUG ASSAY/TIME, min)Yes
Opiate (DRUG ASSAY/TIME, min)Yes
Phenobarbitol (DRUG ASSAY/TIME, min)Yes
Phenytoin (DRUG ASSAY/TIME, min)Yes
Theophylline (DRUG ASSAY/TIME, min)Yes
Additional (Alarms, high/low)Phencyclidine, quinidine, tobramycin
PRE-PROGRAMMED TESTS (SPECIAL/TIME, min)35
OTHER ATTRIBUTES (Interference compensation)Nonlinear data reduction; positive sample ID;
MARKETING REGION (Interference compensation)Worldwide
You may also be interested in the following Manufacturer Specifications:
Disclaimer

Information on this page may be partial or incomplete and may contain mistakes or inaccurate information.

MedWOW disclaims any obligation, responsibility or liability which concerns or relates to any information on this page.

Biochemistry Analyzer, Automated, Boehringer Mannheim Hitachi, 717
View More Items