Manufacturer Specifications - RZ250 ABP Recorder, Rozinn Electronics

Please note: None of the equipment posted for sale on MedWOW.com is owned by MedWOW, should you have any questions regarding a specific item, please direct them to the appropriate seller by making use of the available communication channels on the items page.
MODEL

RZ250 ABP Recorder

Measurement
Time (RECORDER ANNOTATION)Typically 24 hr
Frequency (REPORT DISPLAY)0-6, 12, 15, 20, 30 per hr and on demand
Battery (POWER NEEDED)
Battery used (POWER NEEDED)2 AA alkaline disposable
Rechargeable (POWER NEEDED)2 AA Ni-MH
Duration,hr24
Recharging time, hr (POWER NEEDED)14-16
MEASURING TECHNIQUE (BATTERY)Oscillometric (no electrodes or microphones)
Full disclosure (CENTRAL STATION)Yes
DATA PROCESSING
Interface protocols (DATA PROCESSING)RS232 and USB (with adapter)
Storage≥300300 readings/test, nonvolatile memory
Retrieval (DATA PROCESSING)Computer interface, recall of all readings stored
Event marker (DETECTOR)Yes
Autozero (DETECTOR)Yes
Deflation (PUMP SPECIFICATIONS)Automatic valve
DISPLAYLCD
Inflation (PUMP SPECIFICATIONS)
Pressure, mm hg (AUTO DEFLATE)0-300 max
Method (CHANNEL MEASUREMENTS)Quiet internal pump
CUFF LENGTH (BATTERY)Different sizes available from pediatric to adult
PC SPECIFICATIONS (INFLATION)Pentium PC
Data storage, mb (BATTERY)256 K SA, 512 K .NET
Software (NETWORKING FEATURES)ABP for WindowsSA (stand-alone) 2
Battery used (POWER NEEDED)WindowsSA 98/00/XP, Windows.NET 00/XP Pro Also Windows.NET for network/Internet.
DIMENSIONS (HXWXD) CM, (IN) (DISPLAY)12.8 x 7.8 x 2.7 (5 x 3.1 x 1.1)
WEIGHT, g (oz) (BATTERY)250 (8.8) with batteries
BP MEASUREMENTS
Precision % (BP MEASUREMENTS)3 mm Hg on scale
Systolic range, mm hg (BP MEASUREMENTS)60-290
Diastolic range, mm hg (BP MEASUREMENTS)30-195
PULSE RATE RANGE, bpm (BP MEASUREMENTS)20-240
OTHER ATTRIBUTES (Interference compensation)9 predefined and 2 programmable groups of measurement intervals; day/night analysis; detailed charting and reporting; both stand-alone (SA) and network/Internet (NET) versions of Windows included.
FDA CLEARANCE (Interference compensation)Yes
CE MARK (MDD) (Interference compensation)Yes
MARKETING REGION (Interference compensation)Worldwide
You may also be interested in the following Manufacturer Specifications:
Disclaimer

Information on this page may be partial or incomplete and may contain mistakes or inaccurate information.

MedWOW disclaims any obligation, responsibility or liability which concerns or relates to any information on this page.

Blood Pressure Holter
View More Items