Manufacturer Specifications - ProSpeed, GE Healthcare
Please note: None of the equipment posted for sale on MedWOW.com is owned by MedWOW, should you have any questions regarding a specific item, please direct them to the appropriate seller by making use of the available communication channels on the items page.

| MODEL | ProSpeed |
| X-RAY TUBE | |
| X-RAY TUBE ANODE | |
| Heat storage, hu (X-ray tube anode) | 3500000 |
| Heat dissipation rate, hu/min (X-RAY TUBE) | 820000 |
| Tube focal spot, mm (X-ray tube anode) | 0.62x 0.9, 1.2x 1 |
| POWER NEEDED | 480VAC, 50/60 Hz, 3-phase delta |
| Type (CONFIGURATION) | Single slice helical |
| # of slices (X-ray tube anode) | 1 |
| DISPLAY | |
| Matrixes, pixels (DISPLAY) | 512x 512 |
| Range of ct numbers (DISPLAY) | -1,500to +4,000 |
| Image enlarging scale (DISPLAY) | Up to 16x |
| Max # slices displayed simultaneously (DISPLAY) | 25 |
| Image storage | |
| Hard disk, MB | 1GB; 2 GB optional |
| No. online images (IMAGE STORAGE) | 1,200 (512x 512), 300scan files, 2,260on MOD |
| Archive (IMAGE STORAGE) | Single floppy drive |
| DICOM 3.0 COMPATIBLE (POWER NEEDED, VAC) | Yes |
| IMAGE PROCESSING (MAXIMUM DISPLAY) | |
| Cpu (NETWORK/DATABASE) | Microprocessor based, distributed processor |
| Scan fovs, cm (IMAGE PROCESSING) | 25,35,50 |
| Reconstruction time | |
| Per slice, sec (Reconstruction time) | 5-7; 3-5 optional |
| For localization scan, sec (Reconstruction time) | Real time |
| PERFORMANCE | |
| Minimum interscan time, sec (PERFORMANCE) | 1 |
| Dynamic scan pace (PERFORMANCE) | 30scans/min |
| High-contrast spatial resolution 0%MTF, lp/cm (PERFORMANCE) | 14.5; 18.2 optional |
| 50% mtf, lp/cm (PERFORMANCE) | 6.6; 6.9 optional |
| Low-contrast resolution, mm at %at £4 rads (PERFORMANCE) | 2.5mm at 0.4% |
| Noise, %at £2.5 rads (PERFORMANCE) | 0.35at £4 rads |
| GENERATOR | |
| FLOOR SPACE NEEDED | |
| Size, m2 (FLOOR SPACE NEEDED) | 30 |
| Output, kw (X-RAY GENERATORS) | 30; 42 optional |
| Kvp range (GENERATOR) | 80120100 |
| Ma range (IMAGING SYSTEM) | 60-250; 300,350optional |
| 3-D PACKAGE (DISPLAY) | Optional |
| CT ANGIOGRAPHY (DISPLAY) | Optional |
| TABLE FEATURES | |
| Range of movement | |
| Vertical, cm (Range of movement) | 40-100 |
| Longitudinal, cm (Range of movement) | 150 |
| Scanning range,cm (Range of movement) | 130 |
| Max load capacity with accuracy, kg (Range of movement) | 400 |
| HELICAL SCANNING (DISPLAY) | Yes |
| Max scan time, sec (DISPLAY) | 90 |
| Max scan volume, cm (DISPLAY) | 90 |
| Spatial resolution, lp/cm (DISPLAY) | 14.5at 0%; 18.2 opt |
| Pitch (DISPLAY) | 0.5:1 to 3:1 |
| Reconstruction time per image, sec (DISPLAY) | 5; 3 optional |
| CT SIMULATION (DISPLAY) | Optional |
| GANTRY | |
| Geometry (GANTRY) | Rotate-rotate, low-voltage slip ring |
| Number and type of detectors (GANTRY) | 813+ 14 reference, xenon †† |
| Rotation times, sec 360 (GANTRY) | 1,1.5,2,3; 0.8optional |
| Partial (GANTRY) | 0.7 |
| Slice thickness, mm (GANTRY) | 1,2or 3, 5, 10 |
| X-ray fan beam angle, ° (GANTRY) | 60.4 |
| Gantry angle deg (GANTRY) | -25to +25 |
| Gantry size, hxwxd,cm (GANTRY) | 189x 215 x 95 |
| Gantry weight, kg (GANTRY) | 1980 |
| Gantry opening, cm (GANTRY) | 68 |
| Scan localizer (GANTRY) | Incandescent light |
| OTHER ATTRIBUTES (Interference compensation) | Autoscan; auto- archive; autovoice; enhancement filters; SMART display; simultaneity. |
| FDA CLEARANCE (Interference compensation) | Yes |
| CE MARK (MDD) (Interference compensation) | Yes |
| MARKETING REGION (Interference compensation) | Worldwide *** |
You may also be interested in the following Manufacturer Specifications:
- LightSpeed RT Manufacturer Specification
- HiSpeed CT/e Dual Manufacturer Specification
- LightSpeed 16 Manufacturer Specification
Disclaimer
Information on this page may be partial or incomplete and may contain mistakes or inaccurate information.
CT Scanner, GE Healthcare, ProSpeed
![]() | View More Items | ![]() |