| MODEL | CXR 4 Multi-Slice CT |
| CONFIGURATION OPTIONS | |
| CT scanner mode (CONFIGURATION OPTIONS) | Multislice |
| CT angiography package (CONFIGURATION OPTIONS) | Included standard |
| 3D Image processing and display package (CONFIGURATION OPTIONS) | Included standard |
| Additional clinical applications (CONFIGURATION OPTIONS) | MIP, MPR, Direct Cine Display, LungCAD, CT Colonography optional |
| TECHNICAL SPECIFICATIONS | |
| Dynamic scan rate (TECHNICAL SPECIFICATIONS) | 300 slice/min |
| Image reconstruction time - 2D [Seconds] (TECHNICAL SPECIFICATIONS) | .2 seconds |
| FOV (Min, Max) (TECHNICAL SPECIFICATIONS) | 2-50 cm |
| Automated dosage control (TECHNICAL SPECIFICATIONS) | Yes |
| High contrast spatial resolution at 0% MTF (TECHNICAL SPECIFICATIONS) | 14.31 lp/cm |
| High contrast spatial resolution at 50% MTF (TECHNICAL SPECIFICATIONS) | 3.51 lp/cm |
| Rotation Speed Range (TECHNICAL SPECIFICATIONS) | .8 - 3.0 Min sec. - Max sec. per rotation, increments |
| X-Ray generator kVp range | 100, 120, 130 |
| Gantry diameter (TECHNICAL SPECIFICATIONS) | 70 cm |
| On-line image storage capacity (TECHNICAL SPECIFICATIONS) | 80GB for 20,000 Images |
| Table movement range cm, vertically / longitudinally (TECHNICAL SPECIFICATIONS) | 61/262.5 |
| Table scanning range (TECHNICAL SPECIFICATIONS) | 147 cm |
| Table weight limit [lbs] (TECHNICAL SPECIFICATIONS) | 400 |
| Minimum room size requirements (Length x Width x Height) (TECHNICAL SPECIFICATIONS) | 15 x 11 |
| Power requirements (VAC, Amps) | 208, 3 phrase, 75 KVA |
| Heat output (TECHNICAL SPECIFICATIONS) | 12, 800 BTU |
| INTERFACE CAPABILITY AND SPECIFICATION | |
| DICOM query/retrieve class user/provider (INTERFACE CAPABILITY AND SPECIFICATION) | Yes |
| DICOM storage class user/provider | Yes |
| DICOM storage commit compliant (INTERFACE CAPABILITY AND SPECIFICATION) | Yes |
| DICOM print class user/provider (INTERFACE CAPABILITY AND SPECIFICATION) | Yes |
| DICOM Conformance URL (INTERFACE CAPABILITY AND SPECIFICATION) | 3.0 |
| WARRANTY/SERVICE | |
| Uptime Guarantee % (WARRANTY/SERVICE) | 97 % |
| Availability of remote diagnostic services (WARRANTY/SERVICE) | Unavailable |
| Technical assistance hotline number (WARRANTY/SERVICE) | 1.888.CAT.APPS |
| Warranty length for software [Month(s)] (WARRANTY/SERVICE) | 12 |
| Warranty length on parts[Month(s)] (WARRANTY/SERVICE) | 12 |
| Warranty length on labor [Month(s)] (WARRANTY/SERVICE) | 12 |
| APPLICATIONS TRAINING | |
| Quantity of applications training per installation (APPLICATIONS TRAINING) | 5 days per installation |
| Applications training locale (APPLICATIONS TRAINING) | On-site |
| Includes CME/CEU credits (APPLICATIONS TRAINING) | Yes |
| MARKET DATA/PRODUCT AVAILABILITY | |
| Systems available/Qty. installed in US (MARKET DATA/PRODUCT AVAILABILITY) | 12 |
| Systems available/Qty. installed in Europe (MARKET DATA/PRODUCT AVAILABILITY) | 100 |
| Systems available/Qty. installed in Asia (MARKET DATA/PRODUCT AVAILABILITY) | 100 |
| Year product introduced (MARKET DATA/PRODUCT AVAILABILITY) | 2004 |