MedWOW / Medical Equipment / Imaging / CT Scanner / Siemens / SOMATOM Volume Zoom / Manufacturer Specifications
Manufacturer Specifications - SOMATOM Volume Zoom, Siemens
Please note: None of the equipment posted for sale on MedWOW.com is owned by MedWOW, should you have any questions regarding a specific item, please direct them to the appropriate seller by making use of the available communication channels on the items page.

| MODEL | Siemens SOMATOM PLUS 4 Volume Zoom |
| X-RAY TUBE | |
| X-RAY TUBE ANODE | |
| Heat storage, hu (X-ray tube anode) | 5300000 |
| Heat dissipation rate, hu/min (X-RAY TUBE) | 730,000 (9kW) |
| Tube cooling (X-ray tube anode) | Oil/air, air/water |
| Tube focal spot, mm (X-ray tube anode) | Closed loop integrated; 0.5 x 0.7, 0.8x 1.2 |
| POWER NEEDED | 380-480 VAC, 3-phase, 66-83 kVA |
| Type (CONFIGURATION) | Quad |
| # of slices (X-ray tube anode) | 4 |
| DISPLAY | |
| MONITOR | 21" |
| Matrixes, pixels (DISPLAY) | 1024x 1024 |
| Range of ct numbers (DISPLAY) | -1,024to 3,071 |
| Image enlarging scale (DISPLAY) | Up to 10x |
| Max # slices displayed simultaneously (DISPLAY) | 16 |
| CT ANGIOGRAPHY (DISPLAY) | Optional |
| CT SIMULATION (DISPLAY) | Optional |
| Image storage | |
| Hard disk, MB | 9GB |
| No. online images (IMAGE STORAGE) | 5,000;11,900 optional |
| Archive (IMAGE STORAGE) | CD-R, MOD |
| PERFORMANCE | |
| Minimum interscan time, sec (PERFORMANCE) | 0.25 |
| Dynamic scan pace (PERFORMANCE) | 80scans/min |
| High-contrast spatial resolution 0%MTF, lp/cm (PERFORMANCE) | 30 |
| Low-contrast resolution, mm at %at £4 rads (PERFORMANCE) | 5mm at 0.32% at 2.6 rads |
| Noise, %at £2.5 rads (PERFORMANCE) | 0.35 |
| Output, kw (X-RAY GENERATORS) | 60 |
| Kvp range (GENERATOR) | 80120100 |
| Ma range (IMAGING SYSTEM) | 28 |
| 3-D PACKAGE (DISPLAY) | Optional |
| TABLE FEATURES | |
| Range of movement Vertical, cm (TABLE FEATURES) | 48-102 |
| Longitudinal, cm (Range of movement) | 200 |
| Scanning range,cm (Range of movement) | 157 |
| Max load capacity with accuracy, kg (Range of movement) | 200 |
| FLOOR SPACE NEEDED | |
| Size, m2 (FLOOR SPACE NEEDED) | 29 |
| HELICAL SCANNING (DISPLAY) | Yes |
| Max scan time, sec (DISPLAY) | 100 |
| Max scan volume, cm (DISPLAY) | 157 |
| Spatial resolution, lp/cm (DISPLAY) | 30at 0% MTF |
| Pitch (DISPLAY) | 1:1-8:1 |
| Reconstruction time per image, sec (DISPLAY) | 1 |
| GENERATOR | |
| IMAGE PROCESSING (MAXIMUM DISPLAY) | |
| Cpu (NETWORK/DATABASE) | Multi DSP |
| Scan fovs, cm (IMAGE PROCESSING) | 25/50 |
| Image reconstruction matrixes (IMAGE PROCESSING) | 512x 512 |
| Reconstruction time | |
| Per slice, sec (Reconstruction time) | 1 |
| For localization scan, sec (Reconstruction time) | 1 |
| DICOM 3.0 COMPATIBLE (POWER NEEDED, VAC) | Yes |
| GANTRY | |
| Geometry (GANTRY) | Continuous rotate- rotate, low-voltage slip ring |
| Number and type of detectors (GANTRY) | Ultrafast ceramic |
| # detection channels (GANTRY) | 8x 1,344 |
| Rotation times, sec 360 (GANTRY) | 0.5,0.75,1.0,1.5 |
| Partial (GANTRY) | 0.250,0.33 |
| Slice thickness, mm (GANTRY) | 0.5,1.0,2.5,5,8, 10 |
| X-ray fan beam angle, ° (GANTRY) | 52 |
| Gantry angle deg (GANTRY) | -30to +30 |
| Gantry size, hxwxd,cm (GANTRY) | 199x 89 x 222 |
| Gantry weight, kg (GANTRY) | 2100 |
| Gantry opening, cm (GANTRY) | 70 |
| Scan localizer (GANTRY) | Laser |
| OTHER ATTRIBUTES (Interference compensation) | Quarter-second CT; submillimeter slice thickness; cardiac CT. |
| FDA CLEARANCE (Interference compensation) | Yes |
| MARKETING REGION (Interference compensation) | Worldwide |
You may also be interested in the following Manufacturer Specifications:
- SOMATOM Sensation 10 Manufacturer Specification
- SOMATOM Sensation 16 Manufacturer Specification
- SOMATOM Sensation 64 Manufacturer Specification
Disclaimer
Information on this page may be partial or incomplete and may contain mistakes or inaccurate information.
CT Scanner, Siemens, SOMATOM Volume Zoom
![]() | View More Items | ![]() |