| MODEL | Xpress_GX |
| X-RAY TUBE | |
| X-RAY TUBE ANODE | |
| Heat storage, hu (X-ray tube anode) | 4000000 |
| Heat dissipation rate, hu/min (X-RAY TUBE) | 864000 |
| Tube cooling (X-ray tube anode) | Oil/air |
| Tube focal spot, mm (X-ray tube anode) | 0.9x 0.9, 1.7x 1.1, dual |
| Optional x-ray tubes (X-ray tube anode) | 3,500,000HU |
| POWER NEEDED | 200-240. 380-480 VAC, 100kVA, 3 phase |
| Type (CONFIGURATION) | Single slice helical |
| # of slices (X-ray tube anode) | 1 |
| DICOM 3.0 COMPATIBLE (POWER NEEDED, VAC) | Yes |
| GENERATOR | |
| DISPLAY | |
| MONITOR | 43cm |
| Matrixes, pixels (DISPLAY) | 512x 512 |
| Range of ct numbers (DISPLAY) | -2,047to +6,143 |
| Image enlarging scale (DISPLAY) | Infinitely variable |
| Max # slices displayed simultaneously (DISPLAY) | 16 |
| FLOOR SPACE NEEDED | |
| Size, m2 (FLOOR SPACE NEEDED) | 36 |
| HELICAL SCANNING (DISPLAY) | Yes |
| Max scan time, sec (DISPLAY) | 100 |
| Max scan volume, cm (DISPLAY) | 100 |
| Spatial resolution, lp/cm (DISPLAY) | 18 |
| Reconstruction time per image, sec (DISPLAY) | 3 |
| CT SIMULATION (DISPLAY) | Optional |
| IMAGE PROCESSING (MAXIMUM DISPLAY) | |
| Cpu (NETWORK/DATABASE) | MotorolaMotorola 68040 multimicro- processors, 32- and 64-bit; 256 MB RAM |
| Scan fovs, cm (IMAGE PROCESSING) | 18,24,32,40,50 |
| Image reconstruction matrixes (IMAGE PROCESSING) | 512x 512 |
| Reconstruction time | |
| Per slice, sec (Reconstruction time) | 2 |
| For localization scan, sec (Reconstruction time) | Real time |
| TABLE FEATURES | |
| Range of movement | |
| Vertical, cm (Range of movement) | 30-100 |
| Longitudinal, cm (Range of movement) | 182 |
| Scanning range,cm (Range of movement) | 140 |
| Max load capacity with accuracy, kg (Range of movement) | 450 |
| CT ANGIOGRAPHY (DISPLAY) | Optional |
| Image storage | |
| Hard disk, MB | 3GB |
| No. online images (IMAGE STORAGE) | 1,800 (512x 512), 550raw data files |
| Archive (IMAGE STORAGE) | Optical disk drive and MOD |
| 3-D PACKAGE (DISPLAY) | Optional |
| Output, kw (X-RAY GENERATORS) | 48 |
| Kvp range (GENERATOR) | 80100100000 |
| Ma range (IMAGING SYSTEM) | 50 |
| PERFORMANCE | |
| Minimum interscan time, sec (PERFORMANCE) | 0 |
| Dynamic scan pace (PERFORMANCE) | 100scans/100 sec |
| High-contrast spatial resolution 0%MTF, lp/cm (PERFORMANCE) | 18 |
| 50% mtf, lp/cm (PERFORMANCE) | 10 |
| Low-contrast resolution, mm at %at £4 rads (PERFORMANCE) | 2.5mm at 0.25% |
| Noise, %at £2.5 rads (PERFORMANCE) | £0.5 |
| GANTRY | |
| Geometry (GANTRY) | Rotate-rotate, slip ring |
| Number and type of detectors (GANTRY) | 896+ 1 reference, solid-state |
| # detection channels (GANTRY) | 896 |
| Rotation times, sec 360 (GANTRY) | 1,1.5,2,3,4 |
| Partial (GANTRY) | 0.6 |
| Slice thickness, mm (GANTRY) | 1.2.3.5.7.10 |
| X-ray fan beam angle, ° (GANTRY) | 49 |
| Gantry angle deg (GANTRY) | -30to +30 |
| Gantry size, hxwxd,cm (GANTRY) | 176x 170 x 81 |
| Gantry weight, kg (GANTRY) | 2300 |
| Gantry opening, cm (GANTRY) | 72 |
| Scan localizer (GANTRY) | Laser |
| OTHER ATTRIBUTES (Interference compensation) | 3fps continuous imaging; 360 programmable proto- cols; 32 recordable voice commands; 99 reconstruction algorithms; mouse pull-down menus; gantry control from image monitor; full multitasking; parallel-processing reconstruction; autofilming. |
| FDA CLEARANCE (Interference compensation) | Yes |
| MARKETING REGION (Interference compensation) | Worldwide |
You may also be interested in the following Manufacturer Specifications:
- Aquilion Super4 Manufacturer Specification
- Asteion Super 4 Manufacturer Specification
- Aquilion 16 CFX Manufacturer Specification
Disclaimer
Information on this page may be partial or incomplete and may contain mistakes or inaccurate information.
CT Scanner, Toshiba
![]() | View More Items | ![]() |