Manufacturer Specifications - DWX-50 5-Axis, Roland

Please note: None of the equipment posted for sale on MedWOW.com is owned by MedWOW, should you have any questions regarding a specific item, please direct them to the appropriate seller by making use of the available communication channels on the items page.
MODELRoland DWX-50 5-Axis
Loadable workpiece shapeExternal diameter (step section): 3.85 in to 3.94 in  (98 mm to 100 mm)
Disc External diameter (body section): 3.74 in (95 mm)
Height: .47 to 1.02 (12 to 26 mm)
External diameter: 3.85 in to 3.94 in (98 to 100 mm)
Disc Height: .39 in to .55 in (10 to 14 mm), .63 in to .79 in (16 to 20 mm)
Width x Depth: 1.50 in x 3 in (38 mm x 76 mm) 
BlockHeight: .63 in or .87 in (16 mm or 22 mm)
Operating SpeedX and Y axes 0.24 to 141.73 in./min. (6 to 3600 mm/min.)
Z axis: 6 to 0.24 to 70.87 in./min. (1800 mm/min.)
Spindle speed6,000 to 30,000 rpm
Number of tools housed5
Required tool dimensionsShank diameter: .16in (4 mm), Length: 1.57in to 2.17in (40 to 55 mm)
Required compressed air0.2 to 1.0 MPa (29 psi to 145 psi)
Vacuum requirements8 kPa Static Pressure or more
INTERFACE USB (compliant with Universal Serial Bus Specification Revision 1.1)
POWER CONSUMPTION Voltage and frequency: AC100 to 120 V/220 to 240 V +/-10%, 50/60 Hz
(overvoltage category II, IEC 60664-1) 
Required power capacity: 2.8 A (100 to 120 V)/1.2 A (220 to 240 V) Voltage and frequency: AC100 to 120 V/220 to 240 V +/-10%, 50/60 Hz
POWER CONSUMPTIONApprox. 275W
Operating noiseDuring operation: 70 dB (A) or less (when not cutting)
During standby: 45 dB (A) or less
External DimensionsWidth x Depth x Height: 25.9 x 25.9 x 22 in. (656 x 656 x 557 mm)
WEIGHT110 lb (50 kg)
Installation EnvironmentOperating environment: Temperature of 5 to 40°C (41 to 104 °F), 35 to 80% relative humidity (no condensation) 
Ambient pollution degree: 2 (as specified by IEC 60664-1)
Included items Power cord, USB cable, Setup and Maintenance Guide, Roland Software Package
CD-ROM, Detection pin, Hexagonal screwdriver, Hexagonal wrench, Cap (S and L),
Clamp for block workpiece (A and B), Tool holder, Tool positioner, Dust collection
hose, Regulator, Dust tray etc.
You may also be interested in the following Manufacturer Specifications:
Disclaimer

Information on this page may be partial or incomplete and may contain mistakes or inaccurate information.

MedWOW disclaims any obligation, responsibility or liability which concerns or relates to any information on this page.

Dental Restoration System, Roland , DWX-50 5-Axis