MODEL

Navigator Pro-MASTER (ASSR)

CALIBRATION INDICATORInternal
POWER REQUIRED, VAC110/220
Dimensions (hxwxd),cm (in) (ANTECHAMBER)19.4 x 10.1 x 4.4 (7.6 x 4 x 1.7)
TEST CAPABILITIES
Auditory (TEST CAPABILITIES)Optional; auditory steady-state response standard
Cognitive (TEST CAPABILITIES)P300 - for details please see comments, CNV
COMPUTER AVERAGING
Input channels (COMPUTER AVERAGING)1
Responses averaged (COMPUTER AVERAGING)2 to 64
Adc resolution, bits (COMPUTER AVERAGING)16
Samples per channel (COMPUTER AVERAGING)16000
User programmable (COMPUTER AVERAGING)Yes
DATA MANAGEMENTFFT, ratio calculation
PRINTER (EXTERNAL BEAM)Desk jet with notebook package included
ARTIFACT ELIMINATION (COMPUTER AVERAGING)Yes
INTERFACE PROTOCOL (REPORT DISPLAY)Serial, USB
PROCESSOR TYPE (COMPUTER AVERAGING)Pentium notebook and printer included in price
WAVEFORM DISPLAY (TEST CAPABILITIES)Depends on host computer
Resolution, pixels (GRAPHICS DISPLAY)Depends on host computer
CART MOUNTED (TEST CAPABILITIES)Optional
STORAGE CAPACITY (APERTURE)Hard drive, internal CD-RW
Volatile, traces (COMPUTER AVERAGING)2
AUDITORY STIMULATOR (TEST CAPABILITIES)500-800 Hz; headphones, insert earphone, Ear Muffins, Freefield, bone oscillator
Pulses/sec (TEST CAPABILITIES)Continuous AM/AM+FM signals up to 4/ear simultaneously; exponential AM.
Intensity, db (TEST CAPABILITIES)0 to 132 SPL
AMPLIFIER
Channels (POWER NEEDED)1
Frequency range, hz (AMPLIFIER)30-200
FILTERS
Low, hz (Filters)30
High, hz (Filters)200
SOUND LEVEL (REVOLUTIONS)0.6 rms
Cmrr @ 60 hz, db (Filters)110+
Isolated inputs (Filters)Yes
OTHER SPECIFICATIONS (AIR SUPPLY)Optional diagnostic ABR SW, screening ABR SW, DPOAE SW, TEOAE SW; computer interface required to run tests. Meets requirements of AAMI-ES1, CSA-C22.2 No. 601.1, IEC 60601-1-1, and UL 2601.
FDA CLEARANCE (Interference compensation)Yes
CE MARK (MDD) (Interference compensation)Yes
MARKETING REGION (Interference compensation)Worldwide
You may also be interested in the following Manufacturer Specifications:
Disclaimer

Information on this page may be partial or incomplete and may contain mistakes or inaccurate information.

MedWOW disclaims any obligation, responsibility or liability which concerns or relates to any information on this page.

EMG & Evoked Potential Response Unit, Bio-logic, Explorer
View More Items