Manufacturer Specifications - e.cam Fixed 180, Siemens

Please note: None of the equipment posted for sale on MedWOW.com is owned by MedWOW, should you have any questions regarding a specific item, please direct them to the appropriate seller by making use of the available communication channels on the items page.
MODEL

E.CAM Fixed 180

SPECT (PROCESSOR)Yes
OPTIONAL ATTACHMENTS (SHOCK-WAVE GENERATOR)Pediatric and scintimammography pallets, flash 3-D advanced SPECT interactive reconstruction software, coincidence imaging, upgrade path to variable angle e.cam
SYSTEM SPECIFICATIONS2 single-crystal detectorsvariable angle
POWER NEEDED200-240 ±10% VAC, 50/60 Hz, single phase
DIMENSIONS (HXWXD), CM (IN) (DETECTION PROCESS, HR)193 x 167.6 x 169.5 (76 x 66 x 66.8)
WEIGHT, kg (lb) (DISPLAY)1,755 (3,900) 2
TOTAL BODYYesWith 2 HE collimators
OPERATING PANEL
Persistence scope (OPERATING PANEL)Yes
Zoom regulation (OPERATING PANEL)Yes
RatemeterYes
Scaler (OPERATING PANEL)Yes
Time display (OPERATING PANEL)Yes
Energy selection
Automatic (CALIBRATION)Yes
Manual (CALIBRATION)Yes
Auto peaking (Energy selection)Yes
Image turning control (Energy selection)Yes
Pha window capacity (Energy selection)6 energy windows
Window selection
Automatic (CALIBRATION)Yes
Manual (CALIBRATION)Yes
Auto uniformity correction (Window selection)Yes
FDG-SPECTOptional
HUMIDITY15-80%
CollimatorsLEHS, LEAP, LEHR, LEFB (fanbeam), HE, UHE, pinhole, MELP
DETECTOR/YOKE MOVEMENT
Whole-body scan
Rate, cm/min (Whole-body scan)Above 200 cm/min0.1-240
Mode (IMAGING SYSTEM)Single pass
Area, cm (Whole-body scan)53.3 x 202
Contouring (Whole-body scan)Automatic
Yoke rotation, deg (Whole-body scan)440 CW, 30 CCW
Radius, cm (in) (Whole-body scan)14 min to 67 max LEHR collimator
Detector turning, deg (Whole-body scan)20 cephalic in, 90 caudal out
Clearance
Maximum, cm (in) (Clearance)67 (26.4) LEHR
Minimum, cm (in) (Clearance)9.0 (3.5) HE
PROCESSOR
DATA INPUTAt camera statione. soft A
Processing (PROCESSOR)e. soft P
Data transfer (PROCESSOR)DICOM, TCP/IP
Dicom 3.0 (PROCESSOR)Standard
Display matrix (IMAGE DISPLAY)1280 x 1024
Storage40 GB OS data, 80 GB patient data
HEAT LOADING, BTU/hr (gantry only) (PROCESSOR)6800
STABILITY (max °C change/hour) (PROCESSOR)4.4
DETECTOR CHARACTERISTICS
Crystal dimensions, cm (in) (DETECTOR CHARACTERISTICS)59.1 x 44.5 (23.3 x 17.4)
Thickness, mm (in) (DETECTOR CHARACTERISTICS)9.5 (3/8), optional 15.9 (5/8)
Number of pmts (DETECTOR CHARACTERISTICS)53 (3"), 6 (2") 1
Size, cm (in) (MAXIMUM OBJECT)7.6 (3), 5 (2) Per detector.
Digital detectors (DETECTOR CHARACTERISTICS)ADC on each PMT
COINCIDENCE IMAGINGOptional
SYSTEM FUNCTIONS
Ufov, cm (in) (SYSTEM FUNCTIONS)53.3 x 38.7 (21 x 15.3)
Max. count,cps (SYSTEM FUNCTIONS)310000without scatter
Energy range, kev (SYSTEM FUNCTIONS)50-613 Per detector.
Intrinsic spatial resolution, mm
Fwhm, ufov (Intrinsic spatial resolution, mm)<=3.9
Fwtm, ufov (Intrinsic spatial resolution, mm)<=7.7
Extrinsic spatial resolution (leap)
Fwhm at 10 cm, mm (Extrinsic spatial resolution (leap))7.4 with LEHR
Fwtm at 10 cm, mm (Extrinsic spatial resolution (leap))14.1 with LEHR
System sensitivity, leap, counts/min/uci (Extrinsic spatial resolution (leap))202 with LEHR 1
Intrinsic energy resolution, fwhm, 140 kev (Extrinsic spatial resolution (leap))<=9.9% Per detector.
Intrinsic spatial linearity, mm
Integral ufov (Intrinsic spatial linearity, mm)<=0.7 absolute
Differential ufov (Intrinsic spatial linearity, mm)<=0.2
Intrinsic uniformity, uncorrected
Integral ufov (Intrinsic spatial linearity, mm)<=3.7%
Differential ufov (Intrinsic spatial linearity, mm)<=2.7%
CLINICAL USESGeneral-purpose
OTHER ATTRIBUTES (Interference compensation)HD4 energy-independent detectors, 0.1" low attenuation imaging pallet, auto body contouring, user configurable workflow/display, connectivity to HIS/ RIS/PACS via DICOM worklist/DICOM, syngo multimodality platform. ISO 9001 certified.
FDA CLEARANCE (Interference compensation)Yes
CE MARK (MDD) (Interference compensation)Yes
WHERE MARKETEDWorldwide
You may also be interested in the following Manufacturer Specifications:
Disclaimer

Information on this page may be partial or incomplete and may contain mistakes or inaccurate information.

MedWOW disclaims any obligation, responsibility or liability which concerns or relates to any information on this page.

Gamma Camera, Scanning, Siemens, e.cam Fixed 180
View More Items