Manufacturer Specifications - Symbia S, Siemens

Please note: None of the equipment posted for sale on MedWOW.com is owned by MedWOW, should you have any questions regarding a specific item, please direct them to the appropriate seller by making use of the available communication channels on the items page.
MODELSymbia S
SPECT Yes
OPTIONAL ATTACHMENTS 5/8 in crystal option, Flash 3-D advanced SPECT interactive reconstruction, CT attenuation correction, IDL user programming, e.soft express remote viewing and processing software, dual-monitor display
SYSTEM SPECIFICATIONSDual detector, variable angle
CollimatorsLEHS, LEAP, LEHR, MELP, HE, UHE, pinhole
SYSTEM FUNCTIONS
Differential ufov ≤2.7%
Integral ufov ≤3.7%
Max. count,cps 310,000 without scatter per detector
Fwhm, ufov ≤3.8
Fwtm, ufov ≤7.7
Fwtm at 10 cm, mm 14.1 with LEHR
System sensitivity, LEAP, counts/min/μCi 202 with LEHR per detector; 565 (5/8 in) with MELP
Ufov, cm 53.3 x 38.7 (21 x 15.3)
Intrinsic energy resolution, fwhm, 140 kev ≤9.9%
Integral ufov ≤0.7 absolute
Fwhm at 10 cm, mm 7.4 with LEHR
Differential ufov ≤0.2
Energy range, kev 50-511
POWER NEEDED200/208/220/240 VAC, 47-63 Hz, single phase
WEIGHT, kg 2,624 (5,784), with 2 HE collimators
DIMENSIONS 225 x 193 x 225 (88.7 x 76 x 88.6)
OPERATING PANEL
Persistence scope Yes
Time display Yes
Nonuniform attenuation correction Optional, CT-based, field upgradable to TruePoint SPECT/CT
Image turning control Yes
Pha window capacity 6 energy windows
Autopeaking Yes
Manual Yes
RatemeterYes
Automatic Yes
Scaler Yes
Zoom regulation Yes
Auto uniformity correction Yes
Manual Yes
Automatic Yes
HUMIDITY15-80%
DETECTOR/YOKE MOVEMENT
Mode Single pass
Yoke rotation, deg 405 CW, 135 CCW
Minimum, cm 11.9 (4.7) HE
Maximum, cm 73.2 (28.8) LEHR
Rate, cm/min 3-600
Contouring Automatic
Area, cm 53.3 x 200
Detector turning, deg +/-16
PROCESSOR
Display matrix 1280 x 1024
DATA INPUTe.soft A
Processing e.soft P
Dicom 3.0 Standard
STABILITY 4.4
Storage40 GB OS data, 80 GB patient data
HEAT LOADING, BTU/hr 6,800
Data transfer DICOM, TCP/IP
DETECTOR CHARACTERISTICS
Number of pmts 53 (3 in), 6 (2 in); per detector
Crystal dimensions, cm 59.1 x 44.5 (23.3 x 17.4)
Size, cm 7.6 (3), 5 (2)
Thickness, mm 9.5 (3/8), 15.9 (5/8)
Digital detectors ADC on each PMT
FDG-SPECTYes
TOTAL BODYYes
PLANNING & PURCHASE
CLINICAL USESGeneral nuclear medicine, whole body cardiac and general SPECT; simultaneous dynamic and planar static acquisition, simultaneous gated and ungated SPECT acquisition, dynamic SPECT mode
OTHER ATTRIBUTES SPECT with 76
FDA CLEARANCE Yes
CE MARK Yes
WHERE MARKETEDWorldwide
You may also be interested in the following Manufacturer Specifications:
Disclaimer

Information on this page may be partial or incomplete and may contain mistakes or inaccurate information.

MedWOW disclaims any obligation, responsibility or liability which concerns or relates to any information on this page.

Gamma Camera, Scanning, Siemens, Symbia S