MODEL

Cell-Dyn 4000

TESTING PACE≥100110 (CBC and differential)
POWER REQUIRED, VAC120 ±10%, 50/60 ±3 Hz, 20 A fuse
DIMENSIONS (HXWXD) CM, (IN) (DISPLAY)73.7 x 109.2 x 81.3 (29 x 43 x 32) analyzer and loader, 57.4 x 40.9 x 45.7 (22.6 x 16.1 x 18) data station
WEIGHT, kg (lb) (DISPLAY)148.3 (325.6)
TECHNIQUEFluorescent flow cytometry, DNA/RNA staining and focused flow impedance, MAPSS
STORAGE CAPACITY (APERTURE)16,000 patient reports with histograms and scatterplots
APERTURE
Number (STAINING POSTS)1/flow cell
SAMPLE VOLUME, µL112.5
INTERFACE PROTOCOL (REPORT DISPLAY)RS232 bidirectional host query
PATIENT ID (APERTURE)Bar-code reader 2
WARNING SIGNALS (REVOLUTIONS)VisualMultiple data flags, diagnostic and reagent alerts, operator-selectable alerts Or manual entry available with multiple demographic parameters
MODIFIABLE THRESHOLD (APERTURE)Yes
TESTS (APERTURE)WBC, RBC, Hgb, Hct, MCV, MCHC, RDW, IRF, NRBC#, NRBC%, Plt, MPV, Retic#, Retic%, N#, N%, L#, L%, M#, M%, E#, E%, B#, B%, CD61, CD3/4, CD3/8
VISUAL OUTPUT (APERTURE)Color CRT, ticket printer, graphics printer
CLOSED-TUBE SAMPLING (APERTURE)Yes
ROBOTICS CAPABILITY (APERTURE)Yes
AUTOSAMPLING (APERTURE)Yes
HISTOGRAM DISPLAY (APERTURE)PrinterScatterplots
COINCIDENCE CORRECT (APERTURE)Not required
CALIBRATIONAutomatic, validate every 6 months
DILUTION (APERTURE)Automatic
QC PROGRAMS (APERTURE)25 files, X-B, moving averages for all parameters, Westgard rules, Levey-Jennings and paired differences
CYCLE DURATION, SEC (APERTURE)<45Approx32
START-UP TIME, min (APERTURE)<4
OTHER SPECIFICATIONS (AIR SUPPLY)Directly measured 5-part differential with additional information; directly counted and reported NRBC counts with no interference of NRBCs in white count; ability to monitor cell viability; reports CD3/4 and CD3/8 with number, percent, and ratios; triple-
FDA CLEARANCE (Interference compensation)Yes
MARKETING REGION (Interference compensation)Worldwide
You may also be interested in the following Manufacturer Specifications:
Disclaimer

Information on this page may be partial or incomplete and may contain mistakes or inaccurate information.

MedWOW disclaims any obligation, responsibility or liability which concerns or relates to any information on this page.

Hematology Analyzer, Abbott Laboratories, CELL-DYN 4000
View More Items