| MODEL | Flo-Gard 6301 |
| TOTAL VOLUME INFUSED | |
| Display, ml (TOTAL VOLUME INFUSED) | 1-9,999 |
| KVO RATE, mL/hr (TOTAL VOLUME INFUSED) | 5-6 |
| POWER NEEDED, VAC (ENERGY) | 115 |
| Duration of recharge,hr (TOTAL VOLUME INFUSED) | 80% @ 8 |
| Frequency, hz (REVOLUTIONS) | 60 |
| Battery life (TOTAL VOLUME INFUSED) | 6 @ 1,400; 4 @ 1,400 using both channels |
| DIMENSIONS (HXWXD) (RISE TIME, msec) | 29 x 32.5 x 13 (11.4 x 12.8 x 5.1) |
| WEIGHT, kg (lb) (DISPLAY) | 8.1 |
| FLUID RESISTANT (TOTAL VOLUME INFUSED) | Yes |
| AUDIBLE ALARM | |
| Alarm pause (CONFIGURATION) | Yes |
| VOLUME REGULATION (POWER NEEDED) | Yes |
| AUTOMATIC PIGGYBACKING (ALERTS AND SIGNALS) | Yes |
| PUMP SYSTEM (AUDIBLE ALARM) | Peristaltic type - for details please see comments.Linear peristaltic |
| ALERTS AND SIGNALS | |
| Air in line (ALERTS AND SIGNALS) | Yes |
| Set disengaged (ALERTS AND SIGNALS) | Yes |
| Occlusion downstream (ALERTS AND SIGNALS) | Yes |
| Occlusion upstream (ALERTS AND SIGNALS) | Yes |
| Circuit failure (ALERTS AND SIGNALS) | Yes |
| Infusion terminated (ALERTS AND SIGNALS) | Yes |
| User prompts (ALERTS AND SIGNALS) | Yes |
| Empty battery (ALERTS AND SIGNALS) | Yes |
| Detection mechanism (ALERTS AND SIGNALS) | Benchmarking/selectable |
| Door open (ALERTS AND SIGNALS) | Yes |
| Depleted fluid container (ALERTS AND SIGNALS) | No, VTBI |
| Pressure, psi (ALERTS AND SIGNALS) | Selectable, 3 levels of sensitivity |
| Low battery (EQUIPMENT ALARMS) | Yes |
| DATA LOG (ALERTS AND SIGNALS) | Yes |
| IV SET | |
| Non-needle iv connection (IV SET) | Yes |
| Kind of set (IV SET) | Baxter |
| Free-flow safeguard (IV SET) | Optional - for details please see comments.Optional, depends on configuration |
| NURSE CALL JACK (ALERTS AND SIGNALS) | Yes |
| Number of channels (RECORDER) | 2 |
| FLOW RANGE, mL/hr (AUDIBLE ALARM) | 1-99.9, 1-1,999, in 0.1 mL/hr and 1 mL/hr increments, respectively |
| Accuracy, % (POWER NEEDED) | 5 |
| VTBI SELECTOR, mL (AUDIBLE ALARM) | 1-9,999 |
| OTHER ATTRIBUTES (Interference compensation) | Remote monitoring; postocclusion restart; front-panel indication of flow resistance; selectable options for customized operation; uses standard Baxter IV sets. |
| Supplier Footnotes (PURCHASE INFORMATION) | <1>Specifications current as of March 2004. |
| FDA CLEARANCE (Interference compensation) | Yes |
| MARKETING REGION (Interference compensation) | Worldwide |
You may also be interested in the following Manufacturer Specifications:
- Colleague 3 Manufacturer Specification
- Colleague CX Manufacturer Specification
- Colleague CX 3 Manufacturer Specification
Disclaimer
Information on this page may be partial or incomplete and may contain mistakes or inaccurate information.
Infusion Pump, Baxter, Flo-Gard 6301
![]() | View More Items | ![]() |