MODEL

8000

DRUG/DOSE CALCYes
VTBI SELECTOR, mL (AUDIBLE ALARM)0.1-9,999
POWER NEEDED, VAC (ENERGY)105-135
Frequency, hz (REVOLUTIONS)50/60
Battery life,
hr @ flow (mL/hr) (Battery life,)5@125
Duration of recharge,hr (TOTAL VOLUME INFUSED)18-24
DIMENSIONS (HXWXD) (RISE TIME, msec)24.2x 16.5 x 17.2
WEIGHT, kg (lb) (DISPLAY)4.5
OTHER ATTRIBUTES (Interference compensation)Uses standard IV
Number of channels (RECORDER)1
FLUID RESISTANT (TOTAL VOLUME INFUSED)Yes
FRONT PANEL LOCKOUT (AUDIBLE ALARM)Yes
IV SET
Kind of set (IV SET)Standard gravity
Free-flow safeguard (IV SET)Yes
NEEDLELESS IV
Connection (ALERTS)Yes
MAX UNITS PER POLE (AUDIBLE ALARM)5
TOTAL VOLUME INFUSED
Display, ml (TOTAL VOLUME INFUSED)0.1-9,999
KVO RATE, mL/hr (TOTAL VOLUME INFUSED)0.1-1
PIGGYBACKING (Detection)Yes
ALERTS AND SIGNALS
Occlusion upstream (ALERTS AND SIGNALS)Yes
Occlusion downstream (ALERTS AND SIGNALS)Yes
DETECTION
mechanism (Detection)Pressure transducer,
Pressure, psi (ALERTS AND SIGNALS)2-15, adjustable in increments of 1
Real-time display (ALERTS AND SIGNALS)Yes
Infusion terminated (ALERTS AND SIGNALS)Yes
Air in line (ALERTS AND SIGNALS)Yes
Depleted fluid container (ALERTS AND SIGNALS)Optional
Flow error (ALERTS AND SIGNALS)Yes
Drop sensor (ALERTS AND SIGNALS)Optional
Set disengaged (ALERTS AND SIGNALS)Yes
User prompts (ALERTS AND SIGNALS)Yes
Circuit failure (ALERTS AND SIGNALS)Yes
Low battery (EQUIPMENT ALARMS)Yes
Empty battery (ALERTS AND SIGNALS)Yes
DATA PORT (ALERTS AND SIGNALS)RS232
AUDIBLE ALARM
VOLUME REGULATION (POWER NEEDED)Yes
Alarm pause (CONFIGURATION)2min
DATA LOG (ALERTS AND SIGNALS)Yes
DISPLAYOutput through RS232
PRINTOUT (TEST CAPABILITY)Through PC interface
Time/date stamp (ALERTS AND SIGNALS)Yes
Number of events (COMPATIBLE SYRINGES, mL)380
Events stored (ALERTS AND SIGNALS)Parameter settings,
PUMP SYSTEM (AUDIBLE ALARM)Peristaltic type - for details please see comments.Linear peristaltic
NURSE CALL JACK (ALERTS AND SIGNALS)Yes
Micro (TEST CAPABILITY)Yes
FLOW RANGE, mL/hr (AUDIBLE ALARM)0.1
Accuracy, % (POWER NEEDED)5
FDA CLEARANCE (Interference compensation)Yes
CE MARK (MDD) (Interference compensation)No
MARKETING REGION (Interference compensation)Canada, Central