MedWOW / Medical Equipment / Internal Medicine / Infusion Pump / Sigma / 8000 / Manufacturer Specifications
Manufacturer Specifications - 8000, Sigma
Please note: None of the equipment posted for sale on MedWOW.com is owned by MedWOW, should you have any questions regarding a specific item, please direct them to the appropriate seller by making use of the available communication channels on the items page.

| MODEL | 8000 |
| DRUG/DOSE CALC | Yes |
| VTBI SELECTOR, mL (AUDIBLE ALARM) | 0.1-9,999 |
| POWER NEEDED, VAC (ENERGY) | 105-135 |
| Frequency, hz (REVOLUTIONS) | 50/60 |
| Battery life, | |
| hr @ flow (mL/hr) (Battery life,) | 5@125 |
| Duration of recharge,hr (TOTAL VOLUME INFUSED) | 18-24 |
| DIMENSIONS (HXWXD) (RISE TIME, msec) | 24.2x 16.5 x 17.2 |
| WEIGHT, kg (lb) (DISPLAY) | 4.5 |
| OTHER ATTRIBUTES (Interference compensation) | Uses standard IV |
| Number of channels (RECORDER) | 1 |
| FLUID RESISTANT (TOTAL VOLUME INFUSED) | Yes |
| FRONT PANEL LOCKOUT (AUDIBLE ALARM) | Yes |
| IV SET | |
| Kind of set (IV SET) | Standard gravity |
| Free-flow safeguard (IV SET) | Yes |
| NEEDLELESS IV | |
| Connection (ALERTS) | Yes |
| MAX UNITS PER POLE (AUDIBLE ALARM) | 5 |
| TOTAL VOLUME INFUSED | |
| Display, ml (TOTAL VOLUME INFUSED) | 0.1-9,999 |
| KVO RATE, mL/hr (TOTAL VOLUME INFUSED) | 0.1-1 |
| PIGGYBACKING (Detection) | Yes |
| ALERTS AND SIGNALS | |
| Occlusion upstream (ALERTS AND SIGNALS) | Yes |
| Occlusion downstream (ALERTS AND SIGNALS) | Yes |
| DETECTION | |
| mechanism (Detection) | Pressure transducer, |
| Pressure, psi (ALERTS AND SIGNALS) | 2-15, adjustable in increments of 1 |
| Real-time display (ALERTS AND SIGNALS) | Yes |
| Infusion terminated (ALERTS AND SIGNALS) | Yes |
| Air in line (ALERTS AND SIGNALS) | Yes |
| Depleted fluid container (ALERTS AND SIGNALS) | Optional |
| Flow error (ALERTS AND SIGNALS) | Yes |
| Drop sensor (ALERTS AND SIGNALS) | Optional |
| Set disengaged (ALERTS AND SIGNALS) | Yes |
| User prompts (ALERTS AND SIGNALS) | Yes |
| Circuit failure (ALERTS AND SIGNALS) | Yes |
| Low battery (EQUIPMENT ALARMS) | Yes |
| Empty battery (ALERTS AND SIGNALS) | Yes |
| DATA PORT (ALERTS AND SIGNALS) | RS232 |
| AUDIBLE ALARM | |
| VOLUME REGULATION (POWER NEEDED) | Yes |
| Alarm pause (CONFIGURATION) | 2min |
| DATA LOG (ALERTS AND SIGNALS) | Yes |
| DISPLAY | Output through RS232 |
| PRINTOUT (TEST CAPABILITY) | Through PC interface |
| Time/date stamp (ALERTS AND SIGNALS) | Yes |
| Number of events (COMPATIBLE SYRINGES, mL) | 380 |
| Events stored (ALERTS AND SIGNALS) | Parameter settings, |
| PUMP SYSTEM (AUDIBLE ALARM) | Peristaltic type - for details please see comments.Linear peristaltic |
| NURSE CALL JACK (ALERTS AND SIGNALS) | Yes |
| Micro (TEST CAPABILITY) | Yes |
| FLOW RANGE, mL/hr (AUDIBLE ALARM) | 0.1 |
| Accuracy, % (POWER NEEDED) | 5 |
| FDA CLEARANCE (Interference compensation) | Yes |
| CE MARK (MDD) (Interference compensation) | No |
| MARKETING REGION (Interference compensation) | Canada, Central |
You may also be interested in the following Manufacturer Specifications:
- 8002 Plus Manufacturer Specification
- 8000 Plus Manufacturer Specification
- Spectrum Manufacturer Specification
Disclaimer
Information on this page may be partial or incomplete and may contain mistakes or inaccurate information.
Infusion Pump, Sigma, 8000
![]() | View More Items | ![]() |