Manufacturer Specifications - Accu check Insight, Roche Diagnostics

Please note: None of the equipment posted for sale on MedWOW.com is owned by MedWOW, should you have any questions regarding a specific item, please direct them to the appropriate seller by making use of the available communication channels on the items page.
Easy and intuitive for improved handling

Full colour display with resistive touchscreen for a modern feel
Simple on screen instructions for easy navigation
Safe and reliable to support diabetes management

Proven bolus advisor1–4 to help improve your glycaemic control
Multiple reminders and warnings to give you peace of mind
Discreet and personal to individually adapt to daily life

Full remote control of the pump via the handset - no need to get the pump out
Personalised bolus advice adapted to your needs
Electronic diary with full colour reports and graphs for 
data management on the go   

Handset technical specifications

Dimensions: 52 x 105 x 19 mm
Weight: Approximately 110g
Display: Colour, dot matrix, touchscreen
Automatic power: Auto-on with correct strip insertion
Auto-off after removing strip (2 minutes)
Auto-off after 2 minutes if not used
System operating conditions: See Accu-Chek Aviva test 
strip package insert
Meter storage conditions: -10°C - 50°C (14°F - 122°F)
Relative humidity operating range: 10%–90%
Memory capacity: 2000 diary records
Construction: Handheld
Data port: USB cable for downloading
Power supply: 1 custom lithium-ion rechargeable battery
Power adapter: PHIHONG switching power supply Model PSC03R-050 
Battery life (rechargeable): Under standard usage, 
battery life lasts 3 days on average (based on 7 bG tests, 
bolus adjustments and total on time approximately 52 minutes)
Test principle: Electrochemical
Coding: Universal code key
Bluetooth: Bluetooth used is ISM 2.4 GHz communication channel
The handset and the pump can communicate within a 2 metre range 
Test averages: Test average calculations are offered 
for 7/14/30/60/90 day intervals
Data management:
On-board reports and graphs
Logbook
Trend graph
Target report
Standard week
Standard day
Downloading
Uploading
Bolus advisor: Up to 8 time blocks
Entry for health events (e.g. exercise, stress, illness, etc.)
Reminders: Event-based reminders 
(after low blood glucose, after high blood 
glucose and after meal)
Alarms (up to 8)
Date/appointment reminders (e.g. doctor visit, lab visit, infusion set change)
Medication reminders (up to 5)
Customisable parameters: Vibrate and beep feature 
(one must be on at all times)
10 different sounds possible for reminders
12-hr or 24-hr clock
Hyper and hypo warning limits (beep and/or vibrate)
Background (dark or light)
Backlight (low, medium or high)
Key lock

Insulin pump technical specifications

Dimensions: 72 x 52 x 16 mm without adapter 
84 x 52 x 19 mm with adapter
Weight: Approximately 115 g (including battery, 
full cartridge and infusion set)
Display size:  38 x 15 mm without zoom button, 220 x 80 pixel
Pump casing: Shock/scratch-resistant plastic
Backside metal
Resistant to pharmaceuticals
All edges rounded
Temperature ranges: Operation: +5 °C to +37 °C (+41°F to +99 °F)
Air humidity (relative humidity): Operation: 20% to 90%
Barometric pressure: Operation: 50 to 106 kPa (500 to 1060 mbar)
Power supply: One 1.5-volt AAA Alkaline (LR03) 
or Lithium (FR06) battery
Batteries should have a minimum capacity of 1200 mAh. 
Do not use carbon zinc or nickel cadmium (NiCd) batteries
Basal rate: Minimum = 0.02 U/h , maximum = 25 U/h e.g. 
Below 0.19 U/h, delivery is close dependent. 
0.19 U/h and above delivery every 3 minutes
Bolus: Maximum bolus amount per delivery is 50 U 
(default 25U) Standard, extended and multiwave 
boluses are adjustable in increments of:
1.0 U (20-25 U)
0.05 U (up to 2.0 U)
0.1 U (2-5 U)
0.5 U (10-20 U)
0.2 U (5-10 U)
Duration of extended and multiwave boluses are 
adjustable in intervals of 15 minutes up to 24 hours 
Multiple boluses can run in parallel
Temporary basal rate:
Adjustable in 10% increments, from 0 - 250%
Duration is adjustable in 15 minute intervals, 
up to a maximum of 24 hours
Last duration programmed is the default setting 
for the next temporary basal rate
Bolus delivery rate:
Very slow = 3 U/min
Slow = 6 U/min
Standard = 12 U/min
Moderate = 9 U/min
Maximum pressure: 350 kPa (3500 bar)
Maximum quantity delivered at a single fault condition: 
≤ 0.5 U in case of failure of the pump it would 
give an alarm and go into the stop mode after an 
over or under delivery of max. 0.8 U (normative requirement) 
Maximum time to occlusion alarm:
160 U, glass cartridges (pre-filled):
Minimum basal rate, 0.02 U/h: max 144 h due to tubing/cartridge change
Medium basal rate, 1.0 U/h: = 2.2 h
Data storage capacity:
There are two types of data storage capacities: Data with 
time and date are safely stored in memory for about 1 hour 
after the battery has been removed
Other insulin pump settings and the event 
memory are saved, regardless of battery power 
level and period of time the insulin pump 
has been without power 
Cartridges: Pre-filled 1.6 ml cartridge also available
Infusion sets: Accu-Chek Insight infusion sets 
with a proprietary adapter
Data transfer: Bluetooth® wireless technology
Water tight: IPX8 - protected against the effects of 
temporary immersion in water under standardised 
conditions (1.3 m/4.3 ft for 60 minutes) ex-factory
Safety systems: Alert system, Beeps
Information on the display
Vibrations
Dual microprocessors:
The insulin pump is controlled by two microprocessors. 
The safety concept is based on one processor
(supervisor processor) supervising the other (main processor). 
Whenever a defect or fault occurs in the main processor, 
it is identified by the supervising microprocessor. 
The motor is immediately switched off and an 
"Error E7: ELECTRONIC ERROR" occurs. 
Conversely, the main processor can also determine, 
at any time, whether the supervisor is working correctly
The motor constitutes another important safety component. 
In combination with the main and supervisor 
processors, the brushless motor provides the 
best possible reliability and accuracy in insulin delivery