Manufacturer Specifications - P.F.C Sigma RP Revision Knee System, DePuy

Please note: None of the equipment posted for sale on MedWOW.com is owned by MedWOW, should you have any questions regarding a specific item, please direct them to the appropriate seller by making use of the available communication channels on the items page.
MODEL

P.F.C Sigma RP Revision Knee System

CONDYLAR (Tibial sizing, mm)Bicondylar
PATELLAR IMPLANT
Shape (PATELLAR IMPLANT)Oval dome, round dome, inset all-poly
COMPOSITION402 UHMWPE extruded bar stock
Sizes.mm (PATELLAR IMPLANT)32, 35, 38, 41
TYPE- CEMENTED OR CEMENTLESS (PATELLAR IMPLANT)Cemented
TIBIAL BASE
Anatomic positioning (left/right, both) (TIBIAL INSERT)Universal
COMPOSITIONCobalt chromium alloy
Coating composition (TIBIAL BASE)Porocoat
Sizes available (TIBIAL BASE)7 coated, 7 uncoated
Tibial sizing, mm
Anteroposterior (Tibial sizing, mm)41, 43, 44, 46, 49, 53, 57, 60
Mediolateral (Tibial sizing, mm)62, 65, 67, 70, 75, 81, 87, 92
Instrumentation (Tibial sizing, mm)Intramedullary, extramedullary
Instrument reference points (Tibial sizing, mm)Proximal tibia, tibial canal
Stem angle, ° (Tibial sizing, mm)2
Pcl sparing or pcl substituting (Tibial sizing, mm)Both
Revision features (Tibial sizing, mm)Metaphyseal sleeves, stems and wedges
COMPARTMENTS (TIBIAL INSERT)Tricompartmental
FEMORAL
Femoral shape (FEMORAL)Anatomic, proportional sizing
Anatomic positioning (left/right, both) (TIBIAL INSERT)Left/right
COMPOSITIONCobalt chromium alloy
Coated/uncoated (FEMORAL)Uncoated
Sizes available (TIBIAL BASE)7 uncoated
Femoral sizing, mm
Anteroposterior (Tibial sizing, mm)53, 56, 59, 61, 65, 69, 74
Mediolateral (Tibial sizing, mm)57, 60, 63, 66, 71, 73, 78
Instrumentation (Tibial sizing, mm)Intramedullary, extramedullary
Instrument reference points (Tibial sizing, mm)Intramedullary canal, proximal tibia
OTHER ATTRIBUTES (Interference compensation)Metaphyseal sleeves
TIBIAL INSERT
Anatomic positioning (left/right, both) (TIBIAL INSERT)Universal
COMPOSITIONUHMWPE-1050
Posterior slope angle, ° (TIBIAL INSERT)0
Pcl substituting (TIBIAL INSERT)Yes
Articulating surface hts, mm (TIBIAL INSERT)10, 12.5, 15, 17.5, 20, 22.5, 25, 30
Posterior slope angle, ° (TIBIAL INSERT)0
CONSTRAINEDYes
FDA CLEARANCE (Interference compensation)Yes
CE MARK (MDD) (Interference compensation)Yes
MARKETING REGION (Interference compensation)Worldwide