| MODEL | Agilent - E7405A EMC Spectrum Analyzer |
| PERFORMANCE | |
| : - | 1 Hz to 5 MHz (including 200 Hz, 9 kHz, 120 kHz, 1 MHz EMI BW) |
| : - | +12.5 dBm TOI |
| : - | ≤ 150 dBm displayed average noise level (DANL) |
| : - | Optional (UKB) for lower frequency of 100 Hz |
| FEATURES | |
| : - | Log sweep |
| : - | Built-in preamplifier |
| : - | Optional tracking generator |
| : - | Options included standard are: A4H, AYQ, AYX, UKB, 060, 1DR, 1DS, 1D5 |
| Software | |
| : - | Compatible with E7415A EMI Software |
| : - | Compatible with BenchLink Web Remote Software |
| Radiated emissions | When combined with a broadband antenna, the E7405A provides the capabilities to check for radiated emissions coming from your DUT |
| Conducted emissions | Test for noise or interference placed on power or data lines by coupling the E7405A instrument to the power or data line through a line impedance stabilization network (LISN) device or absorbing clamp |
| Frequency Range | |
| Band LO harmonic = N | |
| 0 1- dc coupled | 30 Hz1 to 3.6 GHz |
| 0 1- ac coupled | 100 MHz to 3.6 GHz |
| 1 1- | 2.85 GHz to 6.7 GHz |
| 2 2- | 6.2 GHz to 13.2 GHz |
| 3 4- | 12.8 GHz to 19.2 GHz |
| 4 4- | 18.7 GHz to 26.5 GHz |
| Sweep Time | |
| Range Span > 0 Hz | 1 ms to 4000 s |
| Range Span = 0 Hz | 50 ns5 to 4000 s |
| Accuracy | +/-1% |
| Sweep trigger | Free run, single, line, video, external, delay, offset, and gate (Option 1D6) |
| Delay trigger range | 1 μs to 400 s |
| Front panel connectors | |
| : - | Input 50 Ω type N (f) |
| : - | RF Out 50 Ω type N (f) |
| Probe power | +15 Vdc, -12.6 Vdc at 150 mA max. characteristic |
| Ext. keyboard | 6-pin mini-DIN, PC keyboards (for entering screen titles and file names) |
| Speaker | Front-panel knob controls volume |
| Headphone | 3.5 mm (1/8 inch) miniature audio jack |
| Rear panel connectors | |
| 10 MHz ref out | 50 Ω, BNC (f), > 0 dBm1 |
| 10 MHz ref in | 50 Ω, BNC (f), -15 to +10 dBm1 |
| Gate trig/ext. trig in | BNC (f), 5 V TTL |
| Gate hi swp out | BNC (f), 5 V TTL |
| VGA output | VGA compatible monitor, 15-pin D-SUB,(31.5 kHz horizontal, 60 Hz vertical sync rates, non-interlaced) Analog RGB 640 x480 |
| GPIB interface | Standard (Option A4H) IEEE-488 bus connector |
| Serial interface | (Option 1AX) RS-232, 9-pin D-SUB (m) |
| Parallel interface | Standard 25-pin D-SUB (f), printer port only |
| WEIGHT | 17.1 kg (37.7 lbs.) |
| DIMENSIONS | |
| Without handle | 222 mm(H) x 409 mm(D) x 373 mm(W) |
| With handle | 222 mm(H) x 516 mm(D) x 416 mm(W) |
| Options and accessories | |
| E7405A-042 | Gray spectrum analyzer backpack |
| E7405A-044 | Yellow spectrum analyzer backpack |
| E7405A-1AX | RS-232 and Centronics interface |
| E7405A-1CP | Rackmount and handle kit |
| E7405A-1D5 | High stability frequency reference |
| E7405A-1D6 | Time-gated spectrum analysis |
| E7405A-1D7 | 50 -75 ohm minimum loss pad(s) |
| E7405A-1DN | 50 Ohm Tracking generator |
| E7405A-230 | BenchLink web remote control software |
| E7405A-A5D | 12 Vdc power cable |
| E7405A-AXT | Add transit case |
| E7405A-AYT | Gray soft carrying/operating case |
| E7405A-AYU | Yellow soft carrying/operating case |
| E7405A-AYX | Fast time-domain sweep |
| E7405A-B70 | BenchLink spectrum analyzer S/W |
| E7405A-STD | Standard Analyzer (1D5, AYX, UKB) |
| E7405A-STG | Standard analyzer with tracking generator (1D5, 1DN, AYX, UKB) |
| E7405A-UK6 | Commercial cal. Certificate w/test data |
| E7405A-UK9 | Front panel cover |
| E7405A-UKB | 100 Hz low frequency extension |