| MODEL | Renaissance II Spirometry System |
| COMPLIES WITH ATS STANDARDS | Yes |
| POWER NEEDED, VAC (ENERGY) | 105-130, 60 Hz; 200-260, 50 Hz |
| Battery (POWER NEEDED) | Ni-Cd rechargeable, AC adapter, 4 AA |
| DIMENSIONS (HXWXD), CM(IN) (ENERGY) | 14.6 x 19.1 x 5.7 (5.8 x 7.5 x 2.3) spirometer, 16.5 x 12.1 x 6.4 (6.5 x 4.8 x 2.5) base |
| WEIGHT, kg (lb) (DISPLAY) | 0.5 (1.1) spirometer, 0.2 (0.5) base |
| Type (CONFIGURATION) | Handheld |
| SINGLE-USE PARTS (PLOTS) | Pneumotach, disposable |
| STERILIZATION PROCESS (PLOTS) | Sterilization not required |
| DATA PROCESSING | Microprocessor |
| User-added data (PLOTS) | ID, patient data, temperature |
| Procedures/params evaluated (PLOTS) | FVC; FEV 1, 3, 6; %FEV 1; FEF 25-75; PEF; FIVC; PIF; FEF 50/FIF 50; FIF 25, 50, 75; FEF 25, 50, 75; FET; MVV; %FEV 6; FEV 6; selectable diagnostic size or hand-validation size |
| Btps correction (PLOTS) | Automatic |
| Actual, normal, % normal report (PLOTS) | Yes |
| Predictive equations (PLOTS) | Morris, Knudson (76, 83), ITS (Crapo) (adult); Polgar, Hsu (pediatric) |
| Respiratory diagnosis (PLOTS) | Yes |
| Serial testing (PLOTS) | Yes |
| Interface protocols (DATA PROCESSING) | RS232 |
| STORAGE MEDIA (POWER USED) | Up to 1,000 patients with internal memory |
| HARD-COPY REPORT (PLOTS) | 8.5 x 11" or A4 |
| Formatted (PLOTS) | Yes |
| Plots size (PLOTS) | ATS specifications |
| PRINTER TYPE | IBM, HP, Canon |
| DISPLAYS (STAINING POSTS) | 2.5 x 3" backlit, real-time graphic |
| PLOTS | |
| Timed spirogram (PLOTS) | Yes |
| Flow-volume loop (PLOTS) | Yes |
| MEASURING UNIT (PLOTS) | Pneumotach(disposable) |
| Volume range, l | 0 |
| Precision (WAVELENGTH, nm) | 3% or 50 mL, whichever is greater |
| Flow range, l/sec | -12 |
| Precision (WAVELENGTH, nm) | 5% or 200 mL, whichever is greater |
| BIDIRECTIONAL (US OUTPUT) | Yes |
| Flow resistance (PLOTS) | <1.5 cm H2O/L/sec |
| CALIBRATION METHOD (SPECIFIC GRAVITY) | 1.6 or 3 L syringe |
| OTHER ATTRIBUTES (Interference compensation) | Enright test quality-assurance program; audio and visual incentives; optional DataFlow data management software ($550-650). |
| FDA CLEARANCE (Interference compensation) | Yes |
| CE MARK (MDD) (Interference compensation) | No |
| MARKETING REGION (Interference compensation) | Canada, USA |
You may also be interested in the following Manufacturer Specifications:
- Simplicity II Spirometry System Manufacturer Specification
- Renaissance Spirometry System Manufacturer Specification
- Renaissance II Spirometry System Manufacturer Specification
Disclaimer
Information on this page may be partial or incomplete and may contain mistakes or inaccurate information.
Spirometer, Nellcor Puritan Bennett, Renaissance II Spirometry System
![]() | View More Items | ![]() |