Manufacturer Specifications - Logiq 9, GE Healthcare

Please note: None of the equipment posted for sale on MedWOW.com is owned by MedWOW, should you have any questions regarding a specific item, please direct them to the appropriate seller by making use of the available communication channels on the items page.
MODEL

LOGIQ 9

FRAME PACE, FPS (SOFTWARE CHARACTERISTICS)Variable to 150
POWER NEEDED100-120/220/240 VAC, 50/60 Hz, 1,200 VA maximum
DIMENSIONS (HXWXD) CM, (IN) (DISPLAY){145-163 x 60 x 89 ({57.1-64.2 x 23.6 x 35)
WEIGHT, kg (lb) (DISPLAY)196 (434)
CLINICAL USESSee comments for possible applications.Abdominal, OB/GYN, breast, small parts, vascular, transcranial, pediatric, neonatal, musculoskeletal, urology
DIVIDED SCREEN (ANALYSIS OPTIONS)Yes
NEEDLE GUIDES
Transrectal (NEEDLE GUIDES)Yes
ANALYSIS KITS
Additional (Alarms, high/low)General, fetal biometry, urology
Vascular scanning (ANALYSIS PACKAGES)Yes
Ob/gyn scanning (ANALYSIS PACKAGES)Yes
USER- DEFINED PROTOCOLS (FUNCTIONS)Extensive
SINGLE/DUAL MONITORS (PAN/ZOOM)Single, 17" highresolution, tilt, swivel
PREPROCESSING (SOFTWARE CHARACTERISTICS)Yes
DOPPLER (SOFTWARE CHARACTERISTICS)
Frequency display (DOPPLER)Yes
Velocity display (DOPPLER)Yes
Power doppler (DOPPLER)Yes
Type (CONFIGURATION)Color, PW w/auto optimize, HPRF, CW, PDI
Duplex mode (DOPPLER)Yes
Triplex mode (DOPPLER)Yes
Gray levels (DIGITAL SYSTEM)256
POSTPROCESSING (MAXIMUM DISPLAY)Including raw data stored images
MAX. DISPLAY
Depth, cm (MAXIMUM DISPLAY)36
DICOM 3.0 COMPATIBLE (POWER NEEDED, VAC)Yes
USER-DEFINED FORMULAS AND TABLESYes
FUNCTIONS
Digital calipers (SOFTWARE CHARACTERISTICS)Yes
Adjustable transmit focus (FUNCTIONALITY)Yes
Dynamic receive focus (FUNCTIONALITY)Yes
Selection of dynamic range (FUNCTIONS)Yes
Video replay (FUNCTIONS)Yes
PAN/ZOOM
Frozen image (PAN/ZOOM)Yes
Real-time image (PAN/ZOOM)Yes
Image storageHard disk, DVD-R, CD-R, videotape. Also USB memory stick.
Cine (DOPPLER)128 MB
Stored image capacity (FUNCTIONS)56 GB hard disk, 4.7 GB CD-R/DVD-R, 512 MB USB stick
IMAGING MODES
M-mode display (IMAGING MODES)Yes
M-mode and 2 dimensional (IMAGING MODES)Yes
3 dimensional (EXTERNAL BEAM)Yes
Harmonic imaging (IMAGING MODES)On all probes
PROBES, MHZ
Vaginal probe (PROBES, MHZ)See comments regarding the vaginal probes4-11 microconvex
Mechanical sector (PROBES)1.5-5, 3-11 curved, 3-10 microconvex. All 3-D/4-D.
Multifrequency (PROBE TYPES, MHz)See comments for the multifrequency capabilities
Convex array (PROBE TYPES, MHz)See comments for frequencies of the transducers.
Phased array (PROBE TYPES, MHz)2.5, 4-11, 1.5-3.5
Rectal probe (PROBES, MHZ)See comments for the choice of rectal probes.4-11 microconvex
Linear array (PROBE TYPES, MHz)See comments for the available linear arrays.3-7, 4-10, 5-12, 5-13
Additional (Alarms, high/low)5-13 linear matrix array, 3-8 convex matrix array, 5-12 intraoperative
OTHER ATTRIBUTES (Interference compensation)Speckle reduction imaging; crossbeam spatial compounding; coded excitation; coded harmonics; coded contrast; auto optimization for B-mode; color/ spectral imaging; virtual convex; anatomical M-mode; InSite ready; LOGIQ View extended FOV; VoiceScan; ILink
FDA CLEARANCE (Interference compensation)Yes
CE MARK (MDD) (Interference compensation)Yes
MARKETING REGION (Interference compensation)Worldwide
MODEL

GE MEDICAL SYSTEMS LOGIQ 9

PROBES, MHZ
Linear array (PROBE TYPES, MHz)See comments for the available linear arrays.3-7.4-10.5-13. 5-12
(convex) array (PROBE TYPES, MHz)2-5.3-8
Phased array (PROBE TYPES, MHz)2-5.4-11
Multifrequency (PROBE TYPES, MHz)See comments for the multifrequency capabilities
Additional (Alarms, high/low)5-13 linear-matrix array, 3-8 convex- matrix array, 5-12 intraoperative
POWER REQUIREMENTS VAC100-120/220/240. 50/60 Hz, 1,200 VA
DIMENSIONS (HXWXD) CM, (IN) (DISPLAY)[145-163] x 60 x 89 ([57-64] x 24 x 35
WEIGHT, kg (lb) (DISPLAY)196(432)
DICOM 3.0 COMPATIBLE (POWER NEEDED, VAC)Yes
IMAGE STORAGE METHODHard disk, MOD, CD-R, videotape
Stored image capacity (FUNCTIONS)20GB hard disk, 1.3 GB MOD, 640 MB CD-RW
M-mode and 2 dimensional (IMAGING MODES)Yes
Harmonic imaging (IMAGING MODES)Yes
Color flow mapping (IMAGING MODES)Yes
Pw (IMAGING MODES)Yes
Other (ROTORS)Color, power, HPRF
POWERYes, 3-D grayscale and color
Velocity display (DOPPLER)Yes
Prf, khz (IMAGING MODES)
Triplex mode (DOPPLER)Yes
PREPROCESSING (SOFTWARE CHARACTERISTICS)Yes
DIVIDED SCREEN (ANALYSIS OPTIONS)Yes
FUNCTIONS
Digital calipers (SOFTWARE CHARACTERISTICS)Yes
Selection of dynamic range (FUNCTIONS)Yes
Adjustable transmit focus (FUNCTIONALITY)Yes
Dynamic receive focus (FUNCTIONALITY)Yes
Measurements on vcr replay (FUNCTIONS)Yes
SINGLE/DUAL MONITORS (PAN/ZOOM)Single, 17" high-res
FRAME PACE, FPS (SOFTWARE CHARACTERISTICS)Variable to 150
ANALYSIS KITS
Cardiac scanning (ANALYSIS PACKAGES)Yes
Vascular scanning (ANALYSIS PACKAGES)Yes
Additional (Alarms, high/low)General, fetal, biometry, urology
DISPLAY FUNCTIONS
Pan/zoom Real-time image (DISPLAY FUNCTIONS)Yes
Frozen image (PAN/ZOOM)Yes
Cine (DOPPLER)Yes
Gray levels (DIGITAL SYSTEM)256
POSTPROCESSING (MAXIMUM DISPLAY)Yes
MAXIMUM DISPLAY DEPTH, cm36
M-mode display (IMAGING MODES)Yes
APPLICATIONS (POWER NEEDED)
Vascular (USES)Yes
Other (ROTORS)Abdominal, vascular, OB/GYN, small parts, breast, urology, transcranial, musculoskeletal, pediatric/neonatal
OTHER ATTRIBUTES (Interference compensation)Digital beamformer; color; B-mode; dual duplex and acoustic output dis- plays; InSite ready; online help; 4 active ports; adjustable-height keyboard; harmonics; DICOM; Automatic Tissue Optimization; TruScan; SmartScan; ComfortScan.
FDA CLEARANCE (Interference compensation)Yes
CE MARK (MDD) (Interference compensation)Yes
MARKETING REGION (Interference compensation)Worldwide
You may also be interested in the following Manufacturer Specifications:
Disclaimer

Information on this page may be partial or incomplete and may contain mistakes or inaccurate information.

MedWOW disclaims any obligation, responsibility or liability which concerns or relates to any information on this page.

Ultrasound, Diagnostic, GE Healthcare, Logiq 9
View More Items