Manufacturer Specifications - ACUSON CV70, Siemens

Please note: None of the equipment posted for sale on MedWOW.com is owned by MedWOW, should you have any questions regarding a specific item, please direct them to the appropriate seller by making use of the available communication channels on the items page.
MODEL

ACUSON CV70

PROBES
Linear array (PROBE TYPES, MHz)4-13
Curvilinear (convex) array (PROBES)Yes
Phased array (PROBE TYPES, MHz)2.1-6
Multifrequency (PROBE TYPES, MHz)Yes
Multiplane tee (PROBES)Yes
Additional (Alarms, high/low)CW 2 and 5 MHz
MARKETED SINCE (GRAPHICS DISPLAY)2003
DICOM 3.0 COMPATIBLE (POWER NEEDED, VAC)Yes
STORAGE MEDIA (POWER USED)DIMAQ-IP workstation, CD-R, videotape, KinetDx, DICOM, digital dynamic clips
DISPLAYS (STAINING POSTS)
Real-time image (PAN/ZOOM)Yes
Frozen image (PAN/ZOOM)Yes
Cine (DOPPLER)Yes
Grayscale levels (SCAN CONVERTER)256
FUNCTIONS
Digital calipers (SOFTWARE CHARACTERISTICS)Yes
Spectrum analyzer (FUNCTIONS)FFT
Selectable dynamic range (FUNCTIONALITY)Yes
Adjustable transmit focus (FUNCTIONALITY)Yes
Dynamic receive focus (FUNCTIONALITY)Yes
SECTOR ANGLE, ° (ANALYSIS OPTIONS)90
FRAME RATE, fps (IMAGING MODES)>160
ANALYSIS OPTIONS
Cardiac scanning (ANALYSIS PACKAGES)Yes
Vascular scanning (ANALYSIS PACKAGES)Yes
Stress echo (ANALYSIS OPTIONS)Yes
WEIGHT, kg (lb) (DISPLAY)130 (286)
IMAGING MODES
M-mode display (IMAGING MODES)Yes
M-mode and 2-d (IMAGING MODES)Yes
Harmonic imaging (IMAGING MODES)Yes
Color flow mapping (IMAGING MODES)Yes
Cw (IMAGING MODES)Yes
Pw (IMAGING MODES)Yes
Additional (Alarms, high/low)Directional power mode
POWERYes
Frequency, mhz (IMAGING SYSTEM)2-13
Velocity display (DOPPLER)Yes
Duplex (IMAGING MODES)Yes
Triplex mode (DOPPLER)Yes
CARDIAC/VASCULAR CONFIGURATION
SINGLE/DUAL MONITORS (PAN/ZOOM)Single
PREPROCESSING (SOFTWARE CHARACTERISTICS)Yes
POSTPROCESSING (MAXIMUM DISPLAY)Yes
MAXIMUM DISPLAY
Depth, cm (MAXIMUM DISPLAY)24
PHYSIOLOGIC DATA (ANALYSIS OPTIONS)Yes
USES (STAINING POSTS)
Cardiac (USES)Yes
Vascular (USES)Yes
Additional (Alarms, high/low)TEE, intraoperative
OTHER ATTRIBUTES (Interference compensation)Utilization of V5M TEE transducer from Aspen and Sequoia platforms; THI; DICOM; CD-RW; stress echo; intraoperative.
FDA CLEARANCE (Interference compensation)Yes
MARKETING REGION (Interference compensation)Worldwide