Manufacturer Specifications - ACUSON Sequoia C512, Siemens

Please note: None of the equipment posted for sale on MedWOW.com is owned by MedWOW, should you have any questions regarding a specific item, please direct them to the appropriate seller by making use of the available communication channels on the items page.
MODEL

ACUSON Sequoia C512

USES (STAINING POSTS)
Cardiac (USES)Adult, pediatric, neonatal, fetal, TEE, intracardiac
Vascular (USES)Yes
Additional (Alarms, high/low)Coronary artery, stress echo, contrast, OR TEE monitoring, 4-D TEE, intraoperative, transcranial, transgenic mouse heart, superficial vascular, endothelium function, abdominal vascular
MARKETED SINCE (GRAPHICS DISPLAY)1996
DICOM 3.0 COMPATIBLE (POWER NEEDED, VAC)Yes
ANALYSIS OPTIONS
Cardiac scanning (ANALYSIS PACKAGES)Yes
Vascular scanning (ANALYSIS PACKAGES)Yes
Stress echo (ANALYSIS OPTIONS)Yes
Additional (Alarms, high/low)OB calc, auto Doppler trace and calc, edge-assisted EF, quantitative strain-rate imaging, autotracking contrast quantification, coronary flow reserve calcs, PISA
PHYSIOLOGIC DATA (ANALYSIS OPTIONS)ECG, PCG, respiration
DISPLAYS (STAINING POSTS)
Real-time image (PAN/ZOOM)Yes
Frozen image (PAN/ZOOM)Yes
Cine (DOPPLER)In all imaging and strip modes
Max number frames (DISPLAYS)Variable, dependent on mode, memory allocation, adjustment; >2,000 (2-D cine mode); >30 sec (strip cine modes)
SINGLE/DUAL MONITORS (PAN/ZOOM)Single; tilt and swivel
FUNCTIONS
Digital calipers (SOFTWARE CHARACTERISTICS)Yes
Spectrum analyzer (FUNCTIONS)FFT
Selectable dynamic range (FUNCTIONALITY)20-100 dB (display), 1 dB increments; >160 dB (total system)
Adjustable transmit focus (FUNCTIONALITY)Yes
Dynamic receive focus (FUNCTIONALITY)Yes
Replay measurement capabilities (FUNCTIONS)Yes
IMAGING MODES
M-mode display (IMAGING MODES)Yes
M-mode and 2-d (IMAGING MODES)Yes
Harmonic imaging (IMAGING MODES)Yes
3-d display (IMAGING MODES)fourSight TEE view
Color flow mapping (IMAGING MODES)Yes
Cw (IMAGING MODES)Steerable, auxilliary
Pw (IMAGING MODES)Yes
Additional (Alarms, high/low)HPRF; Doppler tissue imaging, tissue spectral Doppler, PW spectral and HTD high frame rate tissue Doppler; color Doppler energy; convergent color; harmonic color; power contrast; color M-mode
POWERColor Doppler energy, convergent color
Frequency, mhz (IMAGING SYSTEM)1.75-14
Velocity display (DOPPLER)Yes
Prf, khz (IMAGING MODES)Scale setting dependent
Duplex (IMAGING MODES)Yes
Triplex mode (DOPPLER)Update mode
Grayscale levels (SCAN CONVERTER)256
PROBES
Linear array (PROBE TYPES, MHz)3, 5-6 (6L3), 4-8 (8L5), 7-14 (15L8), 4-8 (8L5T intraoperative)
Curvilinear (convex) array (PROBES)1.5-4.5 (4C1), 2-6 (6C2), 4-8 (8C4)
Phased array (PROBE TYPES, MHz)1.5-4.25 (4V1c), 2-4 (3V2c), 2.5-5 (5V2c), 3.5-7 (7V3c), 5-8.5 (8V5), 4-10 (10V4)
Multifrequency (PROBE TYPES, MHz)All MultiHertz technologyindependent frequency selection across modes
Biplane tee (PROBES)4-8 (V7B)
Multiplane tee (PROBES)3.5-7 (V5Ms), 3.5-8 (V7M)
Pediatric tee (PROBES)Multiplane 3.5-8 (V7M)
Additional (Alarms, high/low)2 Aux CW Doppler; 4-10 (8F), 4-10 (10F) AcuNav catheter
MAXIMUM DISPLAY
Depth, cm (MAXIMUM DISPLAY)36
PREPROCESSING (SOFTWARE CHARACTERISTICS)Yes
DIVIDED SCREEN (ANALYSIS OPTIONS)Dual, live dual imaging
STORAGE MEDIA (POWER USED)HD, MOD, DICOM network, S-VHS VCR, back-and-whiteB&W and color printer, RLE digital lossless compression for static images, JPEG adjustable digital compression for dynamic clips, native DICOM file format
Capacity, number of stored images (DOPPLER)Image-content dependent, up to 36 GB HD, partitioned to 4 GB
POSTPROCESSING (MAXIMUM DISPLAY)Yes
SECTOR ANGLE, (IMAGING MODES)Up to 90, variable
FRAME RATE, fps (IMAGING MODES)>900, variable
CARDIAC/VASCULAR CONFIGURATION
POWER NEEDED, VAC (ENERGY)115/100/230 10, 50/60 Hz
H x W x D, cm (in)148 x 66 x 123 (58 x 26 x 48)
WEIGHT, kg (lb) (DISPLAY)183 (402)
CONFIGURATIONConventional
OTHER ATTRIBUTES (Interference compensation)DICOM: storage class to PACS, storage commitment and verification, print class and verification, modality worklist and performed procedure step; storage to MOD 10BaseT/100BaseT Ethernet output; dynamic transmit focus on select transducers; coherent image
FDA CLEARANCE (Interference compensation)Yes
CE MARK (MDD) (Interference compensation)Yes
MARKETING REGION (Interference compensation)Worldwide
You may also be interested in the following Manufacturer Specifications:
Disclaimer

Information on this page may be partial or incomplete and may contain mistakes or inaccurate information.

MedWOW disclaims any obligation, responsibility or liability which concerns or relates to any information on this page.

Ultrasound, Cardiac, Siemens, ACUSON Sequoia C512
View More Items