Manufacturer Specifications - GALILEO GOLD, Hamilton Medical

Please note: None of the equipment posted for sale on MedWOW.com is owned by MedWOW, should you have any questions regarding a specific item, please direct them to the appropriate seller by making use of the available communication channels on the items page.
MODEL

GALILEO GOLD

MODES OF OPERATION
Assist/control
Volume breaths (Assist/control)Yes
Pressure breaths (Assist/control)Yes
Simv
Volume breaths (Assist/control)Yes
Pressure breaths (Assist/control)Yes
Pressure support (Simv)Yes
Spontaneous/cpap
Pressure support (Simv)Yes
Apnea-backup vent (Spontaneous/cpap)Yes
Combination modes (Spontaneous/cpap)Yes
Responsive valve (Spontaneous/cpap)Yes
Bilevel/aprv (Spontaneous/cpap)Yes
Additional (Alarms, high/low)AVtS, DuoPAP+, DuoPAP, NIV, APV, CMV/IMV
INTERNAL BATTERYYes
Type (number) (ALERTS)Sealed lead-acid (1)
Operating time, hr (Spontaneous/cpap)1 minimum
Rechargeable (POWER NEEDED)Yes
Recharging time, hr (POWER NEEDED)6
DIMENSIONS (HXWXD) CM,(IN) (ALERTS)44 x 62 x 154 (17.3 x 24.5 x 61) with standard trolley
WEIGHT, kg (lb) (DISPLAY)48 (105.8)
Service
Factory/on-site (Service)Yes/yes
3rd-party service (Service)Yes
Parts availability (ALERTS)Yes
Number sold (PURCHASE INFORMATION)
Usa/worldwideNot specified/1,268
PATIENT TYPE (Number sold)Adult, pediatric, neonatal
PNEUMATIC POWER (Volume)
CompressorOptional
Compressed gases (EQUIPMENT ALARMS)O2, air; optional NO
Pressure ranges (EQUIPMENT ALARMS)29-86 psi
PATIENT ALARMS
Fio2 (PATIENT ALARMS)Yes
Low minute volume (REGULATORS)Yes
Low inspiratory pressure (PATIENT ALARMS)Yes
Over pressure (MONITORED PARAMETERS)Yes
Loss of peep (EQUIPMENT ALARMS)Yes
Apnea (CONFIGURATION)Yes
High continuous pressure/occlusion (EQUIPMENT ALARMS)Yes
Inverse ie (PATIENT ALARMS)Text message
High respiratory rate (PATIENT ALARMS)Yes
High minute volume (PATIENT ALARMS)Yes
Breathing circuit disconnect (PATIENT ALARMS)Yes
Additional (Alarms, high/low)Low respiratory rate, low tidal volume, exhalation obstruction, maximum leak compensation, pressure limitation, check Ti, check %VE
DATA DISPLAYED (REGULATORS)Real-time graphics, numerics, waveforms, loops, trends
MONITORED PARAMETERS
Pressure
Pip (MONITORED PARAMETERS)Yes
Map (MONITORED PARAMETERS)Yes
Peep (MONITORED PARAMETERS)Yes
Volume
Tidal (Volume)Yes
Minute (Volume)Yes
Spontaneous minute (Volume)Yes
Fio2 (PATIENT ALARMS)Yes
Respiratory rate (Volume)Yes
Inspiration time (MONITORED PARAMETERS)Yes
Expiration time (MONITORED PARAMETERS)Yes
Ie (Volume)Yes
Additional (Alarms, high/low)Static compliance, inspiratory/expiratory resistance, inspiratory/expiratory time constant, patient trigger, PO.1, RSBI (f/VT), WOB, pressure-time product, air trapping, auxiliary pressure, minimum pressure, Vleak, % O2
DISPLAYS (STAINING POSTS)Color screen, LCD, TFT
INTERFACING
Output ports (INTERFACING)RS232C
Remote alarm/display (INTERFACING)Yes
ANALOG OUTPUT (CONFIGURATION)Yes
Report generation
DISPLAYOptional (LEONARDO)
Archival disk (Report generation)Event log-on flash drive
ALERTS (CONFIGURATION)
Gas supply malfunction (ALERTS)Yes
Power loss (ALERTS)Yes
Vent inoperative (EQUIPMENT ALARMS)Yes
Low battery (EQUIPMENT ALARMS)Yes
SELF-TESTYes
Additional (Alarms, high/low)Technical faults
POWER NEEDED, VAC (ENERGY)100-240
Current, amps (REGULATORS)2.3 (100 VAC), 1 (240 VAC)
POWER CONSUMPTION, W (OTHER AVAILABLE ROTORS)230 maximum
REGULATORS
Tidal volume, ml (CONTROLS)10-2,000
Inspiratory flow, l/min (REGULATORS)1-180
Inspiratory pressure, cm h2o (REGULATORS)0-100
Respiratory rate, breaths/min (REGULATORS)0.5-120
Inspiratory time, sec (CONTROLS)0.1-10
Expiratory time, sec (REGULATORS)0.2-59.9
Ie ratio (REGULATORS)1:9 to 4:1, 150:1 in DuoPAP mode
Inspiratory hold/plateau (REGULATORS)0-70% cycle time
Expiratory hold (REGULATORS)10 sec maximum
Fio2, % (CONTROLS)21-100
Manual breath (REGULATORS)Yes
Peep/cpap, cm h2o (REGULATORS)0-50
Pressure support, cm h2o (REGULATORS)0-100
Nebulizer (REGULATORS)Yes
Trigger system (REGULATORS)Pressure, flow
Bias/base flow range, l/min (REGULATORS)1-30, automatic
Pressure slope/ramp adjustment (REGULATORS)25-200 msec
Sigh (REGULATORS)Yes
100% o2 (REGULATORS)Yes
Additional (Alarms, high/low)% tube resistance compensation, tube type/size
FDA CLEARANCE (Interference compensation)Yes
CE MARK (MDD) (Interference compensation)Yes
WHERE MARKETEDWorldwide
You may also be interested in the following Manufacturer Specifications:
Disclaimer

Information on this page may be partial or incomplete and may contain mistakes or inaccurate information.

MedWOW disclaims any obligation, responsibility or liability which concerns or relates to any information on this page.

Ventilator, Intensive Care, Hamilton Medical, GALILEO GOLD
View More Items