MODEL

GALILEO

ALERTS (CONFIGURATION)
Gas supply malfunction (ALERTS)Yes
Power loss (ALERTS)Yes
Vent inoperative (EQUIPMENT ALARMS)Yes
Low battery (EQUIPMENT ALARMS)Yes
SELF-TESTYes
Additional (Alarms, high/low)Technical faults
Battery (POWER NEEDED)Yes
Type (number) (ALERTS)Sealed lead-acid
Operating time, hr (Spontaneous/cpap)1
Rechargeable (POWER NEEDED)Yes
Recharging time, hr (POWER NEEDED)6
DIMENSIONS (HXWXD) CM,(IN) (ALERTS)40 x 62 x 154 (15.7 x 24.5 x 61) with standard trolley
WEIGHT, kg (lb) (DISPLAY)44 (97)
Factory/on-site (Service)Yes/yes
TRAINING (SYSTEM CONFIGURATION)Yes
3rd-party service (Service)Yes
Parts availability (ALERTS)Yes
Delivery time, aro (SHOCK-WAVE GENERATOR)45-60 days
Year first sold (PURCHASE INFORMATION)1998
Usa/worldwide
Fiscal year (SHOCK-WAVE GENERATOR)December to November
REGULATORS
Tidal volume, ml (CONTROLS)10-2,000
Insp flow, l/min (REGULATORS)1
Insp press, cm h2o (REGULATORS)0-100
Respiratory rate, breaths/min (REGULATORS)1-120
Insp time, sec (CONTROLS)0.1-9
Exp time, sec (REGULATORS)20-90% cycle time
I:e ratio (REGULATORS)1:9 to 4:1
Insp hold/plateau (REGULATORS)0-70% cycle time
Expiratory hold (REGULATORS)10 sec max
Fio2, % (CONTROLS)21-100
Manual breath (REGULATORS)Yes
Peep/cpap, cm h2o (REGULATORS)0-50
Pressure support, cm h2o (REGULATORS)0-100
Nebulizer (REGULATORS)Yes
Trigger system (REGULATORS)Flow and pressure
Bias/base flow range, l/min (REGULATORS)Automatic
Pressure slope/ramp adjustment (REGULATORS)0.25-200 msec
Sigh (REGULATORS)Yes
100% o2 (REGULATORS)Yes
DATA DISPLAYED (REGULATORS)Real-time graphics, numbers, waveforms, loops, trends
MONITORED PARAMETERS
Pip (MONITORED PARAMETERS)Yes
Map (MONITORED PARAMETERS)Yes
Peep (MONITORED PARAMETERS)Yes
Tidal (Volume)Yes
Minute (Volume)Yes
Spontaneous minute (Volume)Yes
Fio2 (PATIENT ALARMS)Digital
Respiratory rate (Volume)Yes
Inspiration time (MONITORED PARAMETERS)Yes
Expiration time (MONITORED PARAMETERS)Yes
I:e (CONTROLS)Yes
Additional (Alarms, high/low)Insp/exp peak flow, compliance, insp/exp resistance, time constants, patient trigger, air trapping, aux pressure
INTERFACING
Output ports (INTERFACING)RS232C
Remote alrm/display (INTERFACING)Yes
ANALOG OUTPUT (CONFIGURATION)Yes
DISPLAYOptional (LEONARDO)
DISPLAYS (STAINING POSTS)Color screen, LCD, TFT
PATIENT ALERTS O2 (REGULATORS)Yes
Low minute volume (REGULATORS)Yes
Low inspir pressure (REGULATORS)Yes
Over pressure (MONITORED PARAMETERS)Yes
Loss of peep (EQUIPMENT ALARMS)Yes
Apnea (CONFIGURATION)Yes
High continuous pressure/occlusion (EQUIPMENT ALARMS)Yes
High respir rate (REGULATORS)Yes
High minute vol (REGULATORS)Yes
Additional (Alarms, high/low)Disconnection
PNEUMATIC POWER (Volume)
CompressorOptional
Compressed gases (EQUIPMENT ALARMS)O2, air; optional NO
Pressure ranges (EQUIPMENT ALARMS)30-85 psi
POWER NEEDED, VAC (ENERGY)100-240
Current, amps (REGULATORS)2.3 (100V), 1 (240V)
POWER CONSUMPTION, W (OTHER AVAILABLE ROTORS)230 max
MODES OF OPERATION
Volume breaths (Assist/control)Yes
Pressure breaths (Assist/control)Yes
Volume breaths (Assist/control)Yes
Pressure breaths (Assist/control)Yes
Pressure support (Simv)Yes
Pressure support (Simv)Yes
Apnea-backup vent (Spontaneous/cpap)Yes
Additional (Alarms, high/low)AVtS, DuoPAP+, DuoPAP, NIV APV (A/C and SIMV)
OTHER SPECIFICATIONS (AIR SUPPLY)Integral battery backup; 10-70% expiratory trigger sensitivity; insp time max; oxygen analyzer; TRC; P/V tool; ventilation analyzer window; operating modes include AVtS, APV, CPAP, NIV, and spontaneous. Meets requirements of ANSI Z79.10-1979/ Z797-1976, C
FDA CLEARANCE (Interference compensation)Yes
CE MARK (MDD) (Interference compensation)Yes
WHERE MARKETEDWorldwide
You may also be interested in the following Manufacturer Specifications:
Disclaimer

Information on this page may be partial or incomplete and may contain mistakes or inaccurate information.

MedWOW disclaims any obligation, responsibility or liability which concerns or relates to any information on this page.

Ventilator, Intensive Care, Hamilton Medical, GALILEO
View More Items