Manufacturer Specifications - RAPHAEL COLOR, Hamilton Medical

Please note: None of the equipment posted for sale on MedWOW.com is owned by MedWOW, should you have any questions regarding a specific item, please direct them to the appropriate seller by making use of the available communication channels on the items page.
MODEL

RAPHAEL COLOR

MODES OF OPERATION
Assist/control
Volume breaths (Assist/control)Yes
Pressure breaths (Assist/control)Yes
Simv
Volume breaths (Assist/control)Yes
Pressure breaths (Assist/control)Yes
Pressure support (Simv)Yes
Spontaneous/cpap
Pressure support (Simv)Yes
Apnea-backup vent (Spontaneous/cpap)Yes
Combination modes (Spontaneous/cpap)Yes
Responsive valve (Spontaneous/cpap)Yes
Bilevel/aprv (Spontaneous/cpap)Yes
Additional (Alarms, high/low)APRV, DuoPAP, DuoPAP+, NIV
INTERNAL BATTERYYes
Type (number) (ALERTS)Lead-acid (1)
Operating time, hr (Spontaneous/cpap)1 minimum
Rechargeable (POWER NEEDED)Yes
Recharging time, hr (POWER NEEDED)6
DIMENSIONS (HXWXD) CM,(IN) (ALERTS)23.1 x 53 x 35 (9.1 x 20.9 x 13.8) without trolley
WEIGHT, kg (lb) (DISPLAY)16.8 (37) without trolley
Service
Factory/on-site (Service)Yes/yes
3rd-party service (Service)Yes
Parts availability (ALERTS)Yes
Number sold (PURCHASE INFORMATION)
Usa/worldwideNot specified/488
PATIENT TYPE (Number sold)Adult, pediatric
DISPLAYS (STAINING POSTS)Color screen, LCD, TFT
PNEUMATIC POWER (Volume)
CompressorOptional
Compressed gases (EQUIPMENT ALARMS)O2, air
Pressure ranges (EQUIPMENT ALARMS)29-86 psi
POWER NEEDED, VAC (ENERGY)100-240
Current, amps (REGULATORS)0.7 (120 VAC)
POWER CONSUMPTION, W (OTHER AVAILABLE ROTORS)40 VA
ALERTS (CONFIGURATION)
Gas supply malfunction (ALERTS)Yes
Power loss (ALERTS)Yes
Vent inoperative (EQUIPMENT ALARMS)Yes
Low battery (EQUIPMENT ALARMS)Yes
SELF-TESTYes
Additional (Alarms, high/low)Obstruction, maximum leak
PATIENT ALARMS
Fio2 (PATIENT ALARMS)Yes
Low minute volume (REGULATORS)Yes
Over pressure (MONITORED PARAMETERS)Yes
Loss of peep (EQUIPMENT ALARMS)Yes
Apnea (CONFIGURATION)Yes
High continuous pressure/occlusion (EQUIPMENT ALARMS)Yes
Inverse ie (PATIENT ALARMS)Text message
High respiratory rate (PATIENT ALARMS)Yes
High minute volume (PATIENT ALARMS)Yes
Breathing circuit disconnect (PATIENT ALARMS)Yes
Additional (Alarms, high/low)Pressure limitation, high pressure during sigh, exhalation obstructed, disconnection
INTERFACING
Output ports (INTERFACING)RS232C
Remote alarm/display (INTERFACING)Yes
ANALOG OUTPUT (CONFIGURATION)Yes
Report generation
DISPLAYOptional (LEONARDO)
MONITORED PARAMETERS
Pressure
Pip (MONITORED PARAMETERS)Yes
Map (MONITORED PARAMETERS)Yes
Peep (MONITORED PARAMETERS)Yes
Volume
Tidal (Volume)Yes
Minute (Volume)Yes
Spontaneous minute (Volume)Yes
Fio2 (PATIENT ALARMS)Yes
Respiratory rate (Volume)Yes
Inspiration time (MONITORED PARAMETERS)Yes
Expiration time (MONITORED PARAMETERS)Yes
Ie (Volume)Yes
Additional (Alarms, high/low)Inspiratory peak flow, compliance, expiratory resistance
DATA DISPLAYED (REGULATORS)Real-time graphics, numerics, loops, trends
REGULATORS
Tidal volume, ml (CONTROLS)50-2,000
Inspiratory flow, l/min (REGULATORS)0-180
Inspiratory pressure, cm h2o (REGULATORS)0-50 above PEEP/CPAP
Respiratory rate, breaths/min (REGULATORS)0-99
Inspiratory time, sec (CONTROLS)0.1-9.6
Expiratory time, sec (REGULATORS)0.2-59.9
Ie ratio (REGULATORS)9.9:1 to 1:9.9, 150:1 in DuoPAP mode
Inspiratory hold/plateau (REGULATORS)0-70% cycle time
Fio2, % (CONTROLS)21-100
Manual breath (REGULATORS)Yes
Peep/cpap, cm h2o (REGULATORS)0-35
Pressure support, cm h2o (REGULATORS)0-50 above PEEP/CPAP
Nebulizer (REGULATORS)Yes
Trigger system (REGULATORS)Flow
Bias/base flow range, l/min (REGULATORS)1-10, automatic
Pressure slope/ramp adjustment (REGULATORS)50-200 msec
Sigh (REGULATORS)Yes
100% o2 (REGULATORS)Yes
Additional (Alarms, high/low)% tube resistance compensation, tube type/size
FDA CLEARANCE (Interference compensation)Yes
CE MARK (MDD) (Interference compensation)Yes
WHERE MARKETEDWorldwide
You may also be interested in the following Manufacturer Specifications:
Disclaimer

Information on this page may be partial or incomplete and may contain mistakes or inaccurate information.

MedWOW disclaims any obligation, responsibility or liability which concerns or relates to any information on this page.

Ventilator, Intensive Care, Hamilton Medical
View More Items