Manufacturer Specifications - RAPHAEL, Hamilton Medical

Please note: None of the equipment posted for sale on MedWOW.com is owned by MedWOW, should you have any questions regarding a specific item, please direct them to the appropriate seller by making use of the available communication channels on the items page.
MODEL

RAPHAEL

ALERTS (CONFIGURATION)
Gas supply malfunction (ALERTS)Yes
Power loss (ALERTS)Yes
Vent inoperative (EQUIPMENT ALARMS)Yes
Low battery (EQUIPMENT ALARMS)Yes
SELF-TESTYes
Additional (Alarms, high/low)Technical faults
Battery (POWER NEEDED)Yes
Type (number) (ALERTS)Internal
Operating time, hr (Spontaneous/cpap)1
Rechargeable (POWER NEEDED)Yes
Recharging time, hr (POWER NEEDED)6
DIMENSIONS (HXWXD) CM,(IN) (ALERTS)23.1 x 53 x 35 (9.1 x 20.9 x 13.8) without trolley
WEIGHT, kg (lb) (DISPLAY)16.8 (37) without trolley
Factory/on-site (Service)Yes/yes
TRAINING (SYSTEM CONFIGURATION)Yes
3rd-party service (Service)Yes
Parts availability (ALERTS)Yes
Delivery time, aro (SHOCK-WAVE GENERATOR)45-60 days
Year first sold (PURCHASE INFORMATION)2003
Usa/worldwide
Fiscal year (SHOCK-WAVE GENERATOR)December to November
REGULATORS
Tidal volume, ml (CONTROLS)50-2,000
Insp flow, l/min (REGULATORS)0
Insp press, cm h2o (REGULATORS)0-50 above PEEP/CPAP
Respiratory rate, breaths/min (REGULATORS)0-80
Insp time, sec (CONTROLS)0.1-3.2
Exp time, sec (REGULATORS)20-90% cycle time
I:e ratio (REGULATORS)1:9 to 4:1
Insp hold/plateau (REGULATORS)0-70% cycle time
Fio2, % (CONTROLS)21-100
Manual breath (REGULATORS)Yes
Peep/cpap, cm h2o (REGULATORS)0-35
Pressure support, cm h2o (REGULATORS)0-50 above PEEP/CPAP
Nebulizer (REGULATORS)Yes
Trigger system (REGULATORS)Flow
Bias/base flow range, l/min (REGULATORS)Automatic
Pressure slope/ramp adjustment (REGULATORS)Auto set
Sigh (REGULATORS)Yes
100% o2 (REGULATORS)Yes
DATA DISPLAYED (REGULATORS)Real-time graphics, loops, trends
PATIENT ALERTS O2 (REGULATORS)Yes
Low minute volume (REGULATORS)Yes
Over pressure (MONITORED PARAMETERS)Yes
Loss of peep (EQUIPMENT ALARMS)Yes
Apnea (CONFIGURATION)Yes
High continuous pressure/occlusion (EQUIPMENT ALARMS)Yes
High respir rate (REGULATORS)Yes
High minute vol (REGULATORS)Yes
Additional (Alarms, high/low)Disconnection
MONITORED PARAMETERS
Pip (MONITORED PARAMETERS)Yes
Map (MONITORED PARAMETERS)Yes
Peep (MONITORED PARAMETERS)Yes
Tidal (Volume)Yes
Minute (Volume)Yes
Spontaneous minute (Volume)Yes
Fio2 (PATIENT ALARMS)Digital
Respiratory rate (Volume)Yes
Inspiration time (MONITORED PARAMETERS)Yes
Expiration time (MONITORED PARAMETERS)Yes
I:e (CONTROLS)Yes
Additional (Alarms, high/low)Insp peak flow, compliance, exp resistance
INTERFACING
Output ports (INTERFACING)RS232C
Remote alrm/display (INTERFACING)Yes
ANALOG OUTPUT (CONFIGURATION)Yes
DISPLAYLEONARDO
DISPLAYS (STAINING POSTS)Color screen, LCD, TFT
POWER NEEDED, VAC (ENERGY)100-240
Current, amps (REGULATORS)0.7 @ 120 VAC
POWER CONSUMPTION, W (OTHER AVAILABLE ROTORS)40 VA
PNEUMATIC POWER (Volume)
CompressorOptional
Compressed gases (EQUIPMENT ALARMS)O2, air
Pressure ranges (EQUIPMENT ALARMS)29-86 psi
MODES OF OPERATION
Volume breaths (Assist/control)Yes
Pressure breaths (Assist/control)Yes
Volume breaths (Assist/control)Yes
Pressure breaths (Assist/control)Yes
Pressure support (Simv)Yes
Pressure support (Simv)Yes
Apnea-backup vent (Spontaneous/cpap)Yes
Additional (Alarms, high/low)APRV, DuoPAP, DuoPAP+
OTHER SPECIFICATIONS (AIR SUPPLY)Meets requirements of ANSI Z79.10-1979/ Z797-1976, CSA, DIN 13254, GLEM, IEC 60601 and 62D/60601, ISO 121/5359/5369/7767, JMMI, NFC 74-350, SEV, and TUV.
FDA CLEARANCE (Interference compensation)Yes
CE MARK (MDD) (Interference compensation)Yes
WHERE MARKETEDWorldwide
You may also be interested in the following Manufacturer Specifications:
Disclaimer

Information on this page may be partial or incomplete and may contain mistakes or inaccurate information.

MedWOW disclaims any obligation, responsibility or liability which concerns or relates to any information on this page.

Ventilator, Intensive Care, Hamilton Medical