New & Used Bronchoscope

Market Value Calculator
 
Please Note: Search results for this device do not include the following devices, please select the relevant device if it is of interest to you: Video Endoscopy
 
 
 
 
Item Details
Seller details
Item Price (USD)
Year manufactured

Quick Look

 
Device: Bronchoscope
Manufacturer: Olympus
Model: BF-P240
Premium User
Location: United States, Michigan
3,475
-

Quick Look

 
Device: Bronchoscope
Manufacturer: Olympus
Model: BF-P60
Premium User
Location: United States, Michigan
3,775
-

Quick Look

 
Device: Bronchoscope
Manufacturer: Olympus
Model: BF-1T20D
Premium User
Location: United States, Washington
Rating: 89%
1,797
This Seller accepts SafeTrade as a payment method
-

Quick Look

 
Device: Bronchoscope
Manufacturer: Olympus
Model: BF-240
Premium User
Location: United States, Michigan
3,475
-

Quick Look

 
Device: Bronchoscope
Manufacturer: Olympus
Model: BF-P240
Premium User
Location: United States, Michigan
3,975
-

Quick Look

 
Device: Bronchoscope
Manufacturer: Olympus
Model: BF-3C30
Premium User
Location: Japan, Chiba
2,100
-

Quick Look

 
Device: Bronchoscope
Manufacturer: Olympus
Model: BF-P200
Premium User
Location: Japan, Chiba
2,400
-

Quick Look

 
Device: Bronchoscope
Manufacturer: Olympus
Model: BF-200
Premium User
Location: Japan, Chiba
2,600
-

Quick Look

 
Device: Bronchoscope
Manufacturer: Olympus
Model: BF-P20
Premium User
Location: Japan, Chiba
2,000
-

Quick Look

 
Device: Bronchoscope
Manufacturer: Olympus
Model: BF-1T10
Premium User
Location: Japan, Chiba
2,000
-

Quick Look

 
Device: Bronchoscope
Manufacturer: Olympus
Model: BF-B2
Premium User
Location: Japan, Chiba
2,000
-

Quick Look

 
Device: Bronchoscope
Manufacturer: Olympus
Model: BF-200
Premium User
Location: Japan, Chiba
Negotiable
-

Quick Look

 
Device: Bronchoscope
Manufacturer: Olympus
Model: BF-200
Premium User
Location: Japan, Chiba
Negotiable
-

Quick Look

 
Device: Bronchoscope
Manufacturer: Olympus
Model: BF-200
Premium User
Location: Japan, Chiba
Negotiable
-

Quick Look

 
Device: Bronchoscope
Manufacturer: Olympus
Model: BF-N20
Location: United Kingdom, London
3,459
This Seller accepts SafeTrade as a payment method
2012
Page: 1 2 3 4 5

Bronchoscope may also be referred to as :

Video Bronchoscope | Flexible Bronchoscope | Fiber Optics Bronchoscop | Bronchial Endoscope
 

Tips for buying Bronchoscope

  1. Image quality and ease of use are the two most important selection factors for bronchoscopes.
  2. The best way to judge the bronchoscope’s optical quality is through on-site equipment trials. Facilities are encouraged to use each system on a trial basis before purchasing, to allow physicians to offer their input.
  3. Bronchoscopes vary in their image brightness and resolution, depth of focus, magnification, color differentiation, angle of vision, and field of view. Different types include fiber optic bronchoscopes and flexible bronchoscopes.
  4. All controls should be clearly marked and easy to operate.
  5. All bronchoscopes should be clearly marked with depth-of-insertion markers. Their dimensions may vary, especially between adult and pediatric models.
  6. To aid the physician in estimating the location of the structures under view, markers should be no more than 10 cm apart, and their marked position should be accurate to within 1.0 cm.
  7. Bronchial endoscopes should also be compatible with as wide a range of reprocessing agents and devices as possible.
  8. The cleaning requirements of these bronchoscopes should be evaluated by facilities. They should also review their scope reprocessing protocol to ensure that it coincides with the scope manufacturer's reprocessing recommendations.
  9. Some bronchial endoscopes have channels that can be cleaned with a brush.
  10. The purchase of additional bronchoscopes may be needed to fulfill daily caseload requirements if EtO gas sterilization is the preferred reprocessing procedure.
  11. Some facilities automate part of their reprocessing with liquid disinfecting or sterilizing units. Users should turn to the operator's manual when reviewing high-level disinfection or sterilization. They should also look at the hospital's infection control and risk management departments.
  12. Before making a purchase, facilities should consider the sensitivity of the bronchoscope to heat, the required rinse time and temperature, the reuse life of the cleaning solution, and whether manual or automatic processing will be used.
  13. Other factors to consider include: the shelf life of the cleaning solution, the minimum effective concentration, and associated disposal restrictions.
  14. Buyers should also consider safety issues and cost per cycle, as well as the educational options provided by the manufacturer. Facilities should keep in mind that preventive maintenance training can help in avoiding costly repairs to delicate components.
  15. Additional video hardware may be offered. This may include camera adapters, image processors, monitors, and image archiving equipment.
  16. Buyers should confirm compatibility between the bronchoscope and an automatic bronchoscope reprocessor.
Read more valuable tips on the Medical Equipment Buying Guide by MedWOW >>