New & Used C-Arm, OEC

Market Value Calculator
 
Applied Filters

Manufacturer : OEC

  Reset
Please Note: Search results for this device do not include the following devices, please select the relevant device if it is of interest to you: Cath Lab,Digital Angiography,Rad/Fluoro Room, Image Intensifier,Rad/Fluoro Room, Flat Panel
 
 
 
 
Item Details
Seller details
Item Price (USD)
Year manufactured

Quick Look

 
Device: C-Arm
Manufacturer: OEC
Model: Series 9800
Location: United States, New Jersey
95,000
2004

Quick Look

 
Device: C-Arm
Manufacturer: OEC
Model: 9600
Location: United States
20,000
1996

Quick Look

 
Device: C-Arm
Manufacturer: OEC
Model: Series 9600
Location: United States, Florida
Rating: 60%
33,000
1997

Quick Look

 
Device: C-Arm
Manufacturer: OEC
Model: MINI 6600
Location: United States, Ohio
Rating: 100%
23,000
This Seller accepts SafeTrade as a payment method
2000

Quick Look

 
Device: C-Arm
Manufacturer: OEC
Model: 7700 Compact +
Location: Germany, Hesse
Negotiable
-

Quick Look

 
Device: C-Arm
Manufacturer: OEC
Model: Series 9400
Location: United States, North Carolina
20,000
This Seller accepts SafeTrade as a payment method
1995

Quick Look

 
Device: C-Arm
Manufacturer: OEC
Model: 7700 Compact
Location: United States, Florida
26,000
-

Quick Look

 
Device: C-Arm
Manufacturer: OEC
Model: Series 9400
Location: United States, Florida
Rating: 60%
Negotiable
1993

Quick Look

 
Device: C-Arm
Manufacturer: OEC
Model: 7700 Compact +
Location: United States, Florida
29,400
1998

Quick Look

 
Device: C-Arm
Manufacturer: OEC
Model: MINI 6600
Location: United States, Florida
Negotiable
This Seller accepts SafeTrade as a payment method
1997

Quick Look

 
Device: C-Arm
Manufacturer: OEC
Model: Series 9000
Location: United States, Illinois
Negotiable
-

Quick Look

 
Device: C-Arm
Manufacturer: OEC
Model: MINI 6600
Location: United States, New Jersey
Negotiable
1998

Quick Look

 
Device: C-Arm
Manufacturer: OEC
Model: Series 9800
Location: United States, New Jersey
Negotiable
2004

Quick Look

 
Device: C-Arm
Manufacturer: OEC
Model: Series 9600
Location: United States, New Jersey
Negotiable
1996

Quick Look

 
Device: C-Arm
Manufacturer: OEC
Model: Series 9400
Location: United States, New York
Rating: 88%
Negotiable
This Seller accepts SafeTrade as a payment method
-
Page: 1 2 3 4 5
The model & manufacturer of the marked items have changed due to an acquisition between companies, and are also known as:
Current Manufacturer / Model Name Alternative Manufacturer / Model Name
GE Healthcare / OEC 7700 Compact + OEC / 7700 Compact +
GE Healthcare / OEC 9000 OEC / Series 9000

C-Arm may also be referred to as :

Mobile R/F Unit | Mobile Fluoroscopic/Radiographic Unit | C-Arm | Mobile Fluoroscopic Unit | Mobile Fluoroscope | Fluoroscopes, Mobile | C-Arm, Fluoroscopic-Radiographic | C-Arm, X-ray Unit | Fluoroscopic / Radiographic Unit, Mobile
 

Tips for buying C-Arm

  1. There are four basic groups of C-arms, including: mini, low-power, medium-power, and high-power.
  2. When buying mobile C-arms, these three main features should be considered: x-ray power, geometry, and image processing.
  3. Before making a purchase, companies should verify that digital storage and/or transmission devices related to the use of mobile C-arms conform to certain standards.
  4. Mini C-arms should be considered for extremity imaging. These smaller Mobile Fluoroscopic-Radiographic units are designed for use in office and surgical environments. Mini C-arms are most useful when instantaneous imaging of the feet, hands, wrists, elbows, or ankles is needed.
  5. Hand or foot surgeons are likely to be the main users of these C-arm devices. Bone alignment can be visualized in a non-invasive manner, in real time - which makes these units especially useful during external reduction and fixation of fractures.
  6. The other three types of C-arms are usually used in surgical procedures. These systems have been providing more and more imaging tools and increased x-ray power, resulting in more useful imaging and therefore use in cardiac imaging.
  7. There are several benefits for increased x-ray power: it allows greater flexibility for imaging and it shortens exposure times and reduces the risk for error. These benefits may be very important for pediatric and obese patients who may find longer exposure times difficult.
  8. These Mobile Fluoroscopic-Radiographic units should be maneuverable around hospitals and provide positioning flexibility. The geometry of the units is important for achieving its purpose. A great C-arm depth may be preferable, but it can also make the maneuverability a bit more difficult.
  9. For effective and easy usage, the C-arm gantry must have the proper dimensions. For example, it must be deep enough to accommodate obese patients. The mobile C-arm's lower portion must be low enough to fit underneath the hospital's beds and operating room tables.
  10. Isocentric rotation, where the center of rotation is the same as the midpoint between the x-ray tube focal spot and the image intensifier, is beneficial.
  11. Mobile C-arm images should be quickly manipulated with digital image processing. It is recommended to be able to send data and image to PACS.
  12. During fluoroscopic procedures, the C-arm television chain system displays the output of an image intensifier on one or more TV monitors.
  13. High-resolution systems, which are offered by some suppliers, are rarely used and require more radiation. When such a system is needed in a mobile C-arm, it should be able to switch between standard and high-resolution modes.
  14. The C-arm TV chain should have some additional features such as high SNR, a large digital storage capacity, and the ability to add alphanumeric characters for patient identification to a recorded image.
Read more valuable tips on the Medical Equipment Buying Guide by MedWOW >>