New & Used Cardiac Ablation System

Market Value Calculator
 
Seller's Business Type
 
 
 
 
Item Details
Seller details
Item Price (USD)
Year manufactured

Quick Look

 
Device: Cardiac Ablation System
Manufacturer: Medtronic
Model: 60890A
Premium User
Location: United States, Washington
Rating: 89%
530
-

Quick Look

 
Device: Cardiac Ablation System
Manufacturer: Medtronic
Model: 60890A
Location: Germany, Hamburg
1,106
This Seller accepts SafeTrade as a payment method
-

Quick Look

 
Device: Cardiac Ablation System
Manufacturer: Stryker
Model: 406-800
Location: United States, Oklahoma
Negotiable
-

Quick Look

 
Device: Cardiac Ablation System
Manufacturer: Diros Technology
Model: URF-1A
Location: United States, Oklahoma
Negotiable
-

Quick Look

 
Device: Cardiac Ablation System
Manufacturer: Valleylab
Model: Cool-tip RF Ablation System E Series
Location: Germany, North Rhine-Westphalia
Rating: 93%
1,865
-

Quick Look

 
Device: Cardiac Ablation System
Manufacturer: Stryker
Model: SERFAS ENERGY RF Generator
Location: Germany, North Rhine-Westphalia
Rating: 93%
828
-

Quick Look

 
Device: Cardiac Ablation System
Manufacturer: Stryker
Model: SERFAS ENERGY RF Generator
Location: United States, Kentucky
Rating: 95%
Negotiable
-

Quick Look

 
Device: Cardiac Ablation System
Manufacturer: Stryker
Model: SERFAS RF (278-100-000)
Location: United States, Kentucky
Rating: 95%
350
-

Quick Look

 
Device: Cardiac Ablation System
Manufacturer: Stryker
Model: SERFAS ENERGY RF Generator
Location: United States, Kentucky
Rating: 95%
350
-

Quick Look

 
Device: Cardiac Ablation System
Manufacturer: Medtronic
Model: Cardioblate BP
Location: United States, Kentucky
Rating: 95%
750
-
Page: 1 2
The model & manufacturer of the marked items have changed due to an acquisition between companies, and are also known as:
Current Manufacturer / Model Name Alternative Manufacturer / Model Name
Rdg Medical / Neurotherm JK25 T Neurotherm / Neurotherm JK25 T

Cardiac Ablation System may also be referred to as :

Tissue Ablation System | Interstitial Thermotherapy System | Cardiac Thermotherapy | Lesion Generator, Cardiac
 

Tips for buying Cardiac Ablation System

  1. Ablation technologies are combined methods of multiple modalities that are individually used to excise, destroy or otherwise effectively treat tissue therapeutically for the various purposes of removing dead tissue or other biological matter.
  2. To ensure safe and efficient operation of cardiac ablation systems and interstitial thermotherapy systems, facilities need to look into several considerations including: RF generator output, which should be between 0 to 50 W; the waveform should be approximately 500 sinusoidal; stimulator output should range from 0 to 10 V and 0 to 10 mA.
  3. Pulse duration of a cardiac ablation system should be between 0 to 3 msec, with a frequency of 2 to 200 Hz.
  4. To ensure suitable functioning during its operation, the cardiac ablation system should display the current and voltage range, impedance range, and temperature range.
  5. It is recommended to have both visual and audio indicators to show activation. The cardiac ablation system should have a self-test mode and include protective circuits such as patient isolation, fault conditions, and impedance and temperature monitors.
Read more valuable tips on the Medical Equipment Buying Guide by MedWOW >>