New & Used Cardiac Output Computer
Market Value Calculator
Manufacturer
Continent
Condition
Manf. Year From
Manf. Year Until
Price Range (USD)
- Complete Systems (43)
Item Details
Seller details
Item Price (USD)
Year manufactured

Quick Look
Device: Cardiac Output Computer
Manufacturer: Edwards Lifesciences
Model: 9520A
Manufacturer: Edwards Lifesciences
Model: 9520A
Premium User
Location: United States, Washington
Rating: 89%
Location: United States, Washington
Rating: 89%
125
-

Quick Look
Device: Cardiac Output Computer
Manufacturer: B. Braun Biotech
Model: Dualtherm COC
Manufacturer: B. Braun Biotech
Model: Dualtherm COC
Premium User
Location: United States, Washington
Rating: 89%
Location: United States, Washington
Rating: 89%
2,650


-

Quick Look
Device: Cardiac Output Computer
Manufacturer: Siemens
Model: HEMOMED pods
Manufacturer: Siemens
Model: HEMOMED pods
Premium User
Location: United States, Washington
Rating: 89%
Location: United States, Washington
Rating: 89%
280


2000

Quick Look
Device: Cardiac Output Computer
Manufacturer: Baxter
Model: COM-2
Manufacturer: Baxter
Model: COM-2
Premium User
Location: United States, Washington
Rating: 89%
Location: United States, Washington
Rating: 89%
180


-

Quick Look
Device: Patient Monitor Module
Manufacturer: Hewlett Packard
Model: M1012A
Manufacturer: Hewlett Packard
Model: M1012A
Premium User
Location: United States, Washington
Rating: 89%
Location: United States, Washington
Rating: 89%
125


2000

Quick Look
Device: Patient Monitor Module
Manufacturer: Hewlett Packard
Model: M1012A
Manufacturer: Hewlett Packard
Model: M1012A
Premium User
Location: United States, Washington
Rating: 89%
Location: United States, Washington
Rating: 89%
125


2000

Quick Look
Device: Cardiac Output Computer
Manufacturer: Abbott Laboratories
Model: 3300
Manufacturer: Abbott Laboratories
Model: 3300
Premium User
Location: United States, Washington
Rating: 89%
Location: United States, Washington
Rating: 89%
583
-

Quick Look
Device: Patient Monitor Module
Manufacturer: Hewlett Packard
Model: M1012A
Manufacturer: Hewlett Packard
Model: M1012A
Premium User
Location: United States, Washington
Rating: 89%
Location: United States, Washington
Rating: 89%
125


1996

Quick Look
Device: Patient Monitor Module
Manufacturer: Hewlett Packard
Model: M1012A
Manufacturer: Hewlett Packard
Model: M1012A
Premium User
Location: United States, Washington
Rating: 89%
Location: United States, Washington
Rating: 89%
125


1996

Quick Look
Device: Cardiac Output Computer
Manufacturer: Pulsion
Model: PiCCO plus
Manufacturer: Pulsion
Model: PiCCO plus
Location: United Kingdom, London
600


-

Quick Look
Device: Cardiac Output Computer
Manufacturer: Siemens
Model: LIM Cartridge
Manufacturer: Siemens
Model: LIM Cartridge
Location: United Kingdom, London
4,299
2013

Quick Look
Device: Cardiac Output Computer
Manufacturer: Pulsion
Model: PiCCO plus
Manufacturer: Pulsion
Model: PiCCO plus
Location: United Kingdom, London
600


-

Quick Look
Device: Cardiac Output Computer
Manufacturer: Baxter
Model: COM-2
Manufacturer: Baxter
Model: COM-2
Location: Germany, Hamburg
233
-

Quick Look
Device: Patient Monitor
Manufacturer: Edwards Lifesciences
Model: Vigileo
Manufacturer: Edwards Lifesciences
Model: Vigileo
Location: Switzerland, Aargau
Negotiable
2005

Quick Look
Device: Cardiac Output Computer
Manufacturer: Philips
Model: M3012A
Manufacturer: Philips
Model: M3012A
Location: Canada, Quebec
900


2015
Cardiac Output Computer may also be referred to as :
Cardiac Output Unit | Monitor Cardiac Output | Computer, Cardiac Output | Cardiac Output Monitor | Cardiac Output Unit, Thermal Dilution | Cardiac OutputTips for buying Cardiac Output Computer
- Cardiac output computer units display the thermal dilution curves to ensure acceptable injection and dilution.
- The cardiac output monitors should have the capability of removing bad curves to exclude them from the final average.
- These cardiac output computers should provide a digital display of injectate and blood temperatures, and CO consumption constant with injectate volume/temperature controls and hemodynamic calculations.
- The cardiac output computers' range should cover 0 to 12 L/min; the injection volume should be delivered at 3, 5, or 10 mL with a temperature range of 0° to 25°C.
- The cardiac output monitors should provide accurate values with a mean error of 5% or 0.25 L/min, whichever is greater.
- Cardiac output computers should be precise, regardless of the patient's stroke volume or heart rate, and whether room temperature or ice-cold injectate is used (with a large or small volume over any reasonable range of patient temperatures) in either a weak or firm injection rate.
- If the cardiac output monitor unit cannot provide a correct calculation, it should display a message describing and explaining the problem.
- The visual alarm should be easily noticeable and specific to the problem. It should remain on until the problem is corrected; turning off the alarm should be impossible.
- All cardiac output computer controls should be visible and clearly identified with simple and clear functions. They should be protected against accidental setting changes.
- Facilities need to determine whether a stand-alone or a modular cardiac output computer is a better fit for their needs. Depending on a facility's physiologic monitoring equipment, a modular cardiac output monitor may allow existing equipment to monitor cardiac output units.
- It is important to know that some cardiac output monitors can provide trending for curves, while others trend cardiac output units' values. The number of values that can be stored is different among units.
Read more valuable tips on the Medical Equipment Buying Guide by MedWOW >>