Parts: Cath Lab

Applied Filters

Manf. Year From : 1998

  Reset
loupe Medical Part Finder Search for part Are you looking for a specific medical part, and you can't find it anywhere?
We can find it for you, quickly and easily!
Go to Part Finder >>
 
Please Note: Search results for this device do not include the following devices, please select the relevant device if it is of interest to you: Mobile Cath Lab,C-Arm,Digital Angiography,Rad/Fluoro Room, Image Intensifier,Rad/Fluoro Room, Flat Panel
 
 
 
 
Item Details
Seller details
Item Price (USD)
Year manufactured

Quick Look

Brand New Item
Device: Cath Lab
Manufacturer: GE Healthcare
Model: Advantx
Name / Number: MX150 Tube / D2712C

Location: United States, Indiana
Negotiable
This Seller accepts SafeTrade as a payment method
2013

Quick Look

Brand New Item
Device: Cath Lab
Manufacturer: GE Healthcare
Model: Innova 3100
Name / Number: MX160 Tube / D2802A

Location: United States, Indiana
Negotiable
This Seller accepts SafeTrade as a payment method
2014
Page: 1 2 3

Cath Lab may also be referred to as :

Radiographic/Fluoroscopic System, Angiographic-Interventional | X-ray Angiography | Special Procedure Radiographic/Fluoroscopic System | Single-Plane Angiographic System | Radiographic/Fluoroscopic Unit, Special Procedure | Radiographic/Fluoroscopic Unit, Angiographic | Radiographic Fluoroscopic Unit, Angiographic Interventional, Cardiovascular | Interventional Radiographic/Fluoroscopic System | DSA System | Digital Vascular Imaging System | Digital Subtraction Angiography System | Digital Intravascular Angiography System | Digital Subtraction Angiography (DSA) System | Biplane Angiography System | Digital Angiography System | Angiography Unit, Radiography | Cineradiography | Angiography Radiographic/Fluoroscopic System | System, X-ray, Angiography | Radiographic Fluoroscopic Unit, Cardiac Catheterization | Radiographic Fluoroscopic System, Cardiac Catheterization | Cardiac Catheterization Equipment | Cardiac Cath Lab Imaging System, Radiography-Fluoroscopy | Catheterization X-ray System | Interventional Lab

If you have not found your required medical part on the above list, our suppliers can additionally offer you the following medical parts (617):

 
Item Details
Actions
Hard Drive  CDW001151831

Device: Cath Lab

Manufacturer: Philips

Model: Integris CV

Name / Number: Hard Drive / CDW001151831

Request a quote

AdvantX Board Gate/NDF I/F 46-232244

Device: Cath Lab

Manufacturer: GE Healthcare

Model: Advantx E

Name / Number: AdvantX Board Gate/NDF I/F / 46-232244

Request a quote

AdvantX Board Light Pick-up 46-264410G1

Device: Cath Lab

Manufacturer: GE Healthcare

Model: Advantx E

Name / Number: AdvantX Board Light Pick-up / 46-264410G1

Request a quote

Advantx HVT Interface Board 46-232240

Device: Cath Lab

Manufacturer: GE Healthcare

Model: Advantx E

Name / Number: Advantx HVT Interface Board / 46-232240

Request a quote

Advantx Intensifier PS 46-184742-P4

Device: Cath Lab

Manufacturer: GE Healthcare

Model: Advantx E

Name / Number: Advantx Intensifier PS / 46-184742-P4

Request a quote

AdvantX XRII Interface Board 46-264760G1

Device: Cath Lab

Manufacturer: GE Healthcare

Model: Advantx E

Name / Number: AdvantX XRII Interface Board / 46-264760G1

Request a quote

Image intencifier 9" 9896 010 01211

Device: Cath Lab

Manufacturer: Philips

Model: MultiDiagnost Eleva

Name / Number: Image intencifier 9" / 9896 010 01211

Request a quote

Image Intensifier 15" 9896 010 01041

Device: Cath Lab

Manufacturer: Philips

Model: MultiDiagnost Eleva

Name / Number: Image Intensifier 15" / 9896 010 01041

Request a quote

Image Intensifier 9" 9807 200 43701

Device: Cath Lab

Manufacturer: Philips

Model: MultiDiagnost Eleva

Name / Number: Image Intensifier 9" / 9807 200 43701

Request a quote

Image Intensifier PS PS9896-010

Device: Cath Lab

Manufacturer: Philips

Model: MultiDiagnost Eleva

Name / Number: Image Intensifier PS / PS9896-010

Request a quote

Page: 1 2 3 4 5
 

Tips for buying Cath Lab Parts


Tips for Buying Cath Lab Parts

Imaging equipment is the core of the cardiac catheterization laboratory. Cardiac catheterization is an invasive procedure that involves inserting a catheter into a blood vessel in the arm or leg, and guiding it to the heart with the aid of a special x-ray machine.  Contrast media is injected through the catheter so that x-ray movies of valves, coronary arteries and heart chambers are taken.

Before purchasing, it is important to be aware of the following important information about cath lab parts:

  1. A cath lab is an integrated system of several cath lab parts which can be operated in two different modes:
  2. As fluoroscopic equipment, to guide the insertion of the cardiac catheter and for its navigation to the proper site in the heart.
  3. As a cine x-ray camera for fast filming of the injected contrast media in the heart.
  4. The latest cath lab systems make it possible to acquire 3 dimensional (3D) images by rotational angiography. This new technique involves the rotation of both the x-ray tube cath lab part and the image detector cath lab part, to acquire sequential projections from multiple angles and reconstructing them into a 3D data set.
  5. Cath lab equipment is a combined system of several major cath lab parts as follows.
  6. C-Arm or U-Arm is the largest and the heaviest cath lab part. It is either a floor- mounted or ceiling- suspended arc which carries the x-ray tube and the detector.
  7. The x-ray tube is the cath lab part which generates the powerful x-ray pulses in the cine mode. It should be a heavy-duty tube with high-heat capacity and improved heat dissipation. A good cooling system is essential.
  8. The x-ray detecting device is the most sophisticated and yet the most vulnerable cath lab part. In older cath lab systems an image intensifier is used, but in newer models, a flat panel detector is the modern cath lab part which replaces the image intensifier. It is relatively small and it fits modern electronic systems.
  9. The generator is the high-voltage, high-power source cath lab part which is instrumental in energizing the x-ray tube. It should be well-matched to the x-ray tube, and capable of delivering the full current capacity of the x-ray tube in the cine mode.
  10. The special collimation system, another integral cath lab part, can be set for: best image quality and reduced patients’ radiation dose.
  11. The x-Ray switching and pulse controller is a cath lab part which sets the x-ray generator in on/off sequence, both in the fluoroscope and the cine modes.
  12. A specialized digital image processor with program selector is an important cath lab part that can contribute a lot to the diagnostic value of the cine recording and the fluoroscopic imaging.
  13. The patient table is another vital cath lab part. It is mounted in a fixed installation, electronically integrated into the system and manipulated by the operator.
  14. The operating console in the control room is the cath lab part which controls the entire system.
  15. The cath lab monitors which are mounted in the procedure room are central cath lab parts.  The screens display the images, the physiological date, the system parameters etc.
  16. Patient skin dose logging system is the cath lab part which records the estimated patient x-ray dose. This cath lab part is integrated into the system and serves to reduce the x-ray exposure of the patient.
  17. The physiological monitoring system is the cath lab part by which the cardiac and hemodynamic functions are monitored and evaluated. In some procedures it plays a major role.
  18. Another necessary cath lab part is the automatic injector. The function of this injector can be synchronized with the x-ray pulses and the cine system to deliver the contrast media in a timely manner.The physiological monitoring system is the cath lab part by which the cardiac and hemodynamic functions are monitored and evaluated. In some procedures it plays a major role.
  19. Some big medical centers install bi-plane x-ray systems in the cardiac catheterization rooms.  In these situations, one C-arm is floor mounted and the second C-arm is ceiling suspended. Each system includes its own unique set of cath lab parts, but the two systems can be synchronized. Such an approach is used mainly for infant cardiac catheterizations to equalize the quantity of injected contrast media by simultaneously acquiring two images at once.
Read more valuable tips on the Medical Equipment Buying Guide by MedWOW >>