Parts: Cath Lab, GE Healthcare, Advantx SCPU
Applied Filters
State
Condition
Seller's Business Type
![]() | Medical Part Finder | ![]() | Are you looking for a specific medical part, and you can't find it anywhere? We can find it for you, quickly and easily! | Go to Part Finder >> |
Please Note: Search results for this device do not include the following devices, please select the relevant device if it is of interest to you: Mobile Cath Lab,C-Arm,Digital Angiography,Rad/Fluoro Room, Image Intensifier,Rad/Fluoro Room, Flat Panel
- Parts (158)
Item Details
Seller details
Item Price (USD)
Year manufactured
Quick Look
Device: Cath Lab
Manufacturer: GE Healthcare
Model: Advantx SCPU
Name / Number: MAIN SWITCH / 2103022
Manufacturer: GE Healthcare
Model: Advantx SCPU
Name / Number: MAIN SWITCH / 2103022
Location: United States
Negotiable
-
Quick Look
Device: Cath Lab
Manufacturer: GE Healthcare
Model: Advantx SCPU
Name / Number: ROTOR CONTROLLER BOARD / 2103590
Manufacturer: GE Healthcare
Model: Advantx SCPU
Name / Number: ROTOR CONTROLLER BOARD / 2103590
Location: United States
Negotiable
-
Quick Look
Device: Cath Lab
Manufacturer: GE Healthcare
Model: Advantx SCPU
Name / Number: COMMAND 1 BOARD / 2103596
Manufacturer: GE Healthcare
Model: Advantx SCPU
Name / Number: COMMAND 1 BOARD / 2103596
Location: United States
Negotiable
-
Quick Look
Device: Cath Lab
Manufacturer: GE Healthcare
Model: Advantx SCPU
Name / Number: COMMAND 2 BOARD / 2103597
Manufacturer: GE Healthcare
Model: Advantx SCPU
Name / Number: COMMAND 2 BOARD / 2103597
Location: United States
Negotiable
-
Quick Look
Device: Cath Lab
Manufacturer: GE Healthcare
Model: Advantx SCPU
Name / Number: DC POWER SUPPLY BOARD / 2103601
Manufacturer: GE Healthcare
Model: Advantx SCPU
Name / Number: DC POWER SUPPLY BOARD / 2103601
Location: United States
Negotiable
-
Quick Look
Device: Cath Lab
Manufacturer: GE Healthcare
Model: Advantx SCPU
Name / Number: INVERTER ASSEMBLY / 2103602
Manufacturer: GE Healthcare
Model: Advantx SCPU
Name / Number: INVERTER ASSEMBLY / 2103602
Location: United States
Negotiable
-
Quick Look
Device: Cath Lab
Manufacturer: GE Healthcare
Model: Advantx SCPU
Name / Number: INVERTER SCPU / 2104156
Manufacturer: GE Healthcare
Model: Advantx SCPU
Name / Number: INVERTER SCPU / 2104156
Location: United States
Negotiable
-
Quick Look
Device: Cath Lab
Manufacturer: GE Healthcare
Model: Advantx SCPU
Name / Number: FIBER OPTIC CABLE / 2105591
Manufacturer: GE Healthcare
Model: Advantx SCPU
Name / Number: FIBER OPTIC CABLE / 2105591
Location: United States
Negotiable
-
Quick Look
Device: Cath Lab
Manufacturer: GE Healthcare
Model: Advantx SCPU
Name / Number: MAIN POWER SUPPLY BOARD / 2112540
Manufacturer: GE Healthcare
Model: Advantx SCPU
Name / Number: MAIN POWER SUPPLY BOARD / 2112540
Location: United States
Negotiable
-
Quick Look
Device: Cath Lab
Manufacturer: GE Healthcare
Model: Advantx SCPU
Name / Number: EMC FILTER / 2116453
Manufacturer: GE Healthcare
Model: Advantx SCPU
Name / Number: EMC FILTER / 2116453
Location: United States
Negotiable
-
Quick Look
Device: Cath Lab
Manufacturer: GE Healthcare
Model: Advantx SCPU
Name / Number: DISTRIBUTION BOARD / 2127237-3
Manufacturer: GE Healthcare
Model: Advantx SCPU
Name / Number: DISTRIBUTION BOARD / 2127237-3
Location: United States
Negotiable
-
Quick Look
Device: Cath Lab
Manufacturer: GE Healthcare
Model: Advantx SCPU
Name / Number: CPU / 2137442-2
Manufacturer: GE Healthcare
Model: Advantx SCPU
Name / Number: CPU / 2137442-2
Location: United States
Negotiable
-
Quick Look
Device: Cath Lab
Manufacturer: GE Healthcare
Model: Advantx SCPU
Name / Number: COMMAND 1 BOARD / 2141239
Manufacturer: GE Healthcare
Model: Advantx SCPU
Name / Number: COMMAND 1 BOARD / 2141239
Location: United States
Negotiable
-
Quick Look
Device: Cath Lab
Manufacturer: GE Healthcare
Model: Advantx SCPU
Name / Number: TRANSFORMER / 2144183
Manufacturer: GE Healthcare
Model: Advantx SCPU
Name / Number: TRANSFORMER / 2144183
Location: United States
Negotiable
-
Quick Look
Device: Cath Lab
Manufacturer: GE Healthcare
Model: Advantx SCPU
Name / Number: MAIN POWER SUPPLY BOARD / 2150569
Manufacturer: GE Healthcare
Model: Advantx SCPU
Name / Number: MAIN POWER SUPPLY BOARD / 2150569
Location: United States
Negotiable
-
Cath Lab may also be referred to as :
Radiographic/Fluoroscopic System, Angiographic-Interventional | X-ray Angiography | Special Procedure Radiographic/Fluoroscopic System | Single-Plane Angiographic System | Radiographic/Fluoroscopic Unit, Special Procedure | Radiographic/Fluoroscopic Unit, Angiographic | Radiographic Fluoroscopic Unit, Angiographic Interventional, Cardiovascular | Interventional Radiographic/Fluoroscopic System | DSA System | Digital Vascular Imaging System | Digital Subtraction Angiography System | Digital Intravascular Angiography System | Digital Subtraction Angiography (DSA) System | Biplane Angiography System | Digital Angiography System | Angiography Unit, Radiography | Cineradiography | Angiography Radiographic/Fluoroscopic System | System, X-ray, Angiography | Radiographic Fluoroscopic Unit, Cardiac Catheterization | Radiographic Fluoroscopic System, Cardiac Catheterization | Cardiac Catheterization Equipment | Cardiac Cath Lab Imaging System, Radiography-Fluoroscopy | Catheterization X-ray System | Interventional LabTips for buying Cath Lab Parts
Tips for Buying Cath Lab Parts
Imaging equipment is the core of the cardiac catheterization laboratory. Cardiac catheterization is an invasive procedure that involves inserting a catheter into a blood vessel in the arm or leg, and guiding it to the heart with the aid of a special x-ray machine. Contrast media is injected through the catheter so that x-ray movies of valves, coronary arteries and heart chambers are taken.
Before purchasing, it is important to be aware of the following important information about cath lab parts:
- A cath lab is an integrated system of several cath lab parts which can be operated in two different modes:
- As fluoroscopic equipment, to guide the insertion of the cardiac catheter and for its navigation to the proper site in the heart.
- As a cine x-ray camera for fast filming of the injected contrast media in the heart.
- The latest cath lab systems make it possible to acquire 3 dimensional (3D) images by rotational angiography. This new technique involves the rotation of both the x-ray tube cath lab part and the image detector cath lab part, to acquire sequential projections from multiple angles and reconstructing them into a 3D data set.
- Cath lab equipment is a combined system of several major cath lab parts as follows.
- C-Arm or U-Arm is the largest and the heaviest cath lab part. It is either a floor- mounted or ceiling- suspended arc which carries the x-ray tube and the detector.
- The x-ray tube is the cath lab part which generates the powerful x-ray pulses in the cine mode. It should be a heavy-duty tube with high-heat capacity and improved heat dissipation. A good cooling system is essential.
- The x-ray detecting device is the most sophisticated and yet the most vulnerable cath lab part. In older cath lab systems an image intensifier is used, but in newer models, a flat panel detector is the modern cath lab part which replaces the image intensifier. It is relatively small and it fits modern electronic systems.
- The generator is the high-voltage, high-power source cath lab part which is instrumental in energizing the x-ray tube. It should be well-matched to the x-ray tube, and capable of delivering the full current capacity of the x-ray tube in the cine mode.
- The special collimation system, another integral cath lab part, can be set for: best image quality and reduced patients’ radiation dose.
- The x-Ray switching and pulse controller is a cath lab part which sets the x-ray generator in on/off sequence, both in the fluoroscope and the cine modes.
- A specialized digital image processor with program selector is an important cath lab part that can contribute a lot to the diagnostic value of the cine recording and the fluoroscopic imaging.
- The patient table is another vital cath lab part. It is mounted in a fixed installation, electronically integrated into the system and manipulated by the operator.
- The operating console in the control room is the cath lab part which controls the entire system.
- The cath lab monitors which are mounted in the procedure room are central cath lab parts. The screens display the images, the physiological date, the system parameters etc.
- Patient skin dose logging system is the cath lab part which records the estimated patient x-ray dose. This cath lab part is integrated into the system and serves to reduce the x-ray exposure of the patient.
- The physiological monitoring system is the cath lab part by which the cardiac and hemodynamic functions are monitored and evaluated. In some procedures it plays a major role.
- Another necessary cath lab part is the automatic injector. The function of this injector can be synchronized with the x-ray pulses and the cine system to deliver the contrast media in a timely manner.The physiological monitoring system is the cath lab part by which the cardiac and hemodynamic functions are monitored and evaluated. In some procedures it plays a major role.
- Some big medical centers install bi-plane x-ray systems in the cardiac catheterization rooms. In these situations, one C-arm is floor mounted and the second C-arm is ceiling suspended. Each system includes its own unique set of cath lab parts, but the two systems can be synchronized. Such an approach is used mainly for infant cardiac catheterizations to equalize the quantity of injected contrast media by simultaneously acquiring two images at once.
Read more valuable tips on the Medical Equipment Buying Guide by MedWOW >>