New & Used Chest X-ray
Market Value Calculator
Manufacturer
Continent
Condition
Manf. Year From
Manf. Year Until
Price Range (USD)
Please Note: Search results for this device do not include the following devices, please select the relevant device if it is of interest to you: Rad Room, Digital,Rad Room, Analog
- Complete Systems (32)
- Parts (615)
Item Details
Seller details
Item Price (USD)
Year manufactured

Quick Look
Device: Chest X-ray
Manufacturer: Hitachi
Model: DHF-155H II
Manufacturer: Hitachi
Model: DHF-155H II
Premium User
Location: Japan, Chiba
Location: Japan, Chiba
Negotiable
-

Quick Look
Device: Chest X-ray
Manufacturer: Fuji
Model: FDR Unity
Manufacturer: Fuji
Model: FDR Unity
Premium User
Location: United States, Washington
Rating: 89%
Location: United States, Washington
Rating: 89%
92,560


2008

Quick Look
Device: Chest X-ray
Manufacturer: GE Healthcare
Model: Revolution XQ/i
Manufacturer: GE Healthcare
Model: Revolution XQ/i
Premium User
Location: United States, Washington
Rating: 89%
Location: United States, Washington
Rating: 89%
49,920


2005

Quick Look
Device: Chest X-ray
Manufacturer: Philips
Model: Digital Diagnost VR
Manufacturer: Philips
Model: Digital Diagnost VR
Location: United Kingdom, Buckinghamshire
10,401
2000

Quick Look
Device: Chest X-ray
Manufacturer: Siemens
Model: Klinograph
Manufacturer: Siemens
Model: Klinograph
Location: Germany, Hamburg
3,491


1992

Quick Look
Device: Chest X-ray
Manufacturer: Trex Medical
Model: ACS-2000
Manufacturer: Trex Medical
Model: ACS-2000
Location: United Arab Emirates
7,999
2000

Quick Look
Device: Rad Room, Digital
Manufacturer: Philips
Model: Digital Diagnost VR
Manufacturer: Philips
Model: Digital Diagnost VR
Location: Germany, North Rhine-Westphalia
29,090
-

Quick Look
Device: Chest X-ray
Manufacturer: Philips
Model: THORAVISION
Manufacturer: Philips
Model: THORAVISION
Location: Germany, Hamburg
5,818


2000

Quick Look
Device: Chest X-ray
Manufacturer: Siemens
Model: Axiom Multix MP
Manufacturer: Siemens
Model: Axiom Multix MP
Location: United Kingdom, Buckinghamshire
71,956


2006

Quick Look
Device: Chest X-ray
Manufacturer: Siemens
Model: Axiom Multix MP
Manufacturer: Siemens
Model: Axiom Multix MP
Location: United Kingdom, Buckinghamshire
71,956


2007

Quick Look
Device: Chest X-ray
Manufacturer: GE Healthcare
Model: Revolution XQ/i
Manufacturer: GE Healthcare
Model: Revolution XQ/i
Location: France, Provence-Alpes-Côte-d'Azur
Rating: 100%
Rating: 100%
23,272
2003

Quick Look
Device: Chest X-ray
Manufacturer: Carestream
Model: DIRECTVIEW DR 7500 Wall Mount
Manufacturer: Carestream
Model: DIRECTVIEW DR 7500 Wall Mount

Location: United States, North Carolina
5,000
2008

Quick Look
Device: Chest X-ray
Manufacturer: Siemens
Model: Axiom Multix MP
Manufacturer: Siemens
Model: Axiom Multix MP
Location: Germany, Saxony
58,180
2009

Quick Look
Device: Chest X-ray
Manufacturer: Siemens
Model: Axiom Multix MP
Manufacturer: Siemens
Model: Axiom Multix MP
Location: Germany, Saxony
52,362
2010
The model & manufacturer of the marked items have changed due to an acquisition between companies, and are also known as:
Current Manufacturer / Model Name | Alternative Manufacturer / Model Name |
---|---|
Carestream / DIRECTVIEW DR 7500 Wall Mount | Kodak / DirectView DR 7500 Wall |
Chest X-ray may also be referred to as :
X-ray, Chest Unit | Radiographic Unit, Chest, Multibeam Equalization | Multibeam Equalization Radiographic Unit | Chest X-ray Unit | Chest Radiographic Unit | Radiographic Unit, ChestTips for buying Chest X-ray
- Buyers in the market for Chest Radiographic Units should consider an x-ray generator with 3-phase, 12-pulse output or the equivalent with an appropriate power rating; an x-ray tube with a dual focal spot; and an anode with a high-speed rotor.
- For chest x-ray procedures, a 5 kW generator is acceptable. If other projections - such as lumbar spine - are necessary, users should consider an 80 kW generator.
- An external cassette holder is one of the available options, which allows the use of either portrait or landscape alignment of 35 × 43 cm film.
- Another option on some Multibeam Equalization Radiographic Units is film-size interchangeability.
- There are several advantages to digital chest x-ray systems over conventional chest radiographic units. The main one is that the dynamic range of digital imaging receptors is much larger than that of x-ray film. While x-ray film can record exposure differences of approximately 100:1, digital imaging receptors record differences of approximately 10,000:1. This large dynamic range allows a wider range of exposures, diminishing the need for additional exposures.
- Other benefits of direct digital chest x-ray imaging include: post processing features, electronic storage, and networking capability.
- Chest Radiographic Unit image quality is defined by pixel size and the signal-to-noise characteristics of the detector. Digital chest x-ray systems must produce high-quality radiographs fast and effectively.
- Some systems can read out and process an image in less than 10 seconds, while nontraditional techniques take over a minute. This time is not the same as the cycle time. Some systems with longer image-readout time can re-expose the patient before the final image is ready. Therefore, even the busiest system only needs to process up to 60 images per hour.
- To deliver images to radiologists without further manipulation, advanced chest x-ray image processing must be available after the image is produced.
- Advanced applications, such as dual energy subtraction, temporal subtraction, and computer-aided detection, can be done with digital image capture. This allows collecting more information from simple chest x-rays.
- To facilitate future network additions, all newly purchased equipment should be compliant with the DX class of the DICOM 3.0 standard.
- Suppliers need to provide DICOM-conformance statements. These should explain in detail which information objects, service classes, and data encoding are supported by the chest x-ray system. The statements should be inspected by a competent specialist, and should share the same format and vocabulary to facilitate comparisons between suppliers.
- Facilities should verify compatibility among components if they plan to integrate the chest radiographic unit with other x-ray components.
- Facilities should consider overhead patient-support bars in departments examining extremely ill or debilitated patients.
- Some chest x-ray units require keypunch cards or file cards for patient identification. Others accept both.
- A stereo-shift option for depth-perception studies or support belts for securing the patient against the unit are not offered by all chest x-ray manufacturers.
Read more valuable tips on the Medical Equipment Buying Guide by MedWOW >>