New & Used Cytometer
Market Value Calculator
Manufacturer
Continent
Condition
Manf. Year From
Manf. Year Until
Price Range (USD)
More Filters
- Complete Systems (17)
Item Details
Seller details
Item Price (USD)
Year manufactured
Quick Look
Device: Cytometer
Manufacturer: Beckman Coulter
Model: FACSort
Manufacturer: Beckman Coulter
Model: FACSort
Location: United States, California
5,000 
-
Quick Look
Device: Cytometer
Manufacturer: Beckman Coulter
Model: EPICS ALTRA Cell Sorter
Manufacturer: Beckman Coulter
Model: EPICS ALTRA Cell Sorter
Location: Singapore
4,000
2006
Quick Look
Device: Cytometer
Manufacturer: Becton Dickinson
Model: FACSAria
Manufacturer: Becton Dickinson
Model: FACSAria
Location: Germany, Baden-Wurttemberg
Rating: 90%
Rating: 90%
Negotiable
-
Quick Look
Device: Cytometer
Manufacturer: Becton Dickinson
Model: FACS Vantage SE
Manufacturer: Becton Dickinson
Model: FACS Vantage SE
Location: United States, Massachusetts
Rating: 100%
Rating: 100%
26,500
1998
Quick Look
Device: Cytometer
Manufacturer: Beckman Coulter
Model: Cytomics FC 5000 MCL
Manufacturer: Beckman Coulter
Model: Cytomics FC 5000 MCL
Location: Germany, Baden-Wurttemberg
Rating: 90%
Rating: 90%
Negotiable
2005
Quick Look
Device: Cytometer
Manufacturer: Becton Dickinson
Model: FACS Vantage SE
Manufacturer: Becton Dickinson
Model: FACS Vantage SE
Location: United States, New Jersey
Negotiable
-
Quick Look
Device: Cytometer
Manufacturer: Becton Dickinson
Model: FACSCalibur
Manufacturer: Becton Dickinson
Model: FACSCalibur
Location: Belarus, Horad Minsk
10,000 
2006
Quick Look
Device: Cytometer
Manufacturer: Beckman Coulter
Model: Cytomics FC 5000 MCL
Manufacturer: Beckman Coulter
Model: Cytomics FC 5000 MCL
Location: United States, California
42,500
-
Quick Look
Device: Cytometer
Manufacturer: Beckman Coulter
Model: Cytomics FC 5000 MCL
Manufacturer: Beckman Coulter
Model: Cytomics FC 5000 MCL
Location: Germany, Baden-Wurttemberg
Rating: 90%
Rating: 90%
Negotiable
2006
Quick Look
Device: Cytometer
Manufacturer: Beckman Coulter
Model: EPICS ALTRA Cell Sorter
Manufacturer: Beckman Coulter
Model: EPICS ALTRA Cell Sorter
Location: France, Île-de-France
30,000 
2001
Quick Look
Device: Cytometer
Manufacturer: Becton Dickinson
Model: FACSAria
Manufacturer: Becton Dickinson
Model: FACSAria
Location: Germany, Baden-Wurttemberg
Rating: 90%
Rating: 90%
Negotiable
2006
Quick Look
Device: Cytometer
Manufacturer: Becton Dickinson
Model: FACSAria
Manufacturer: Becton Dickinson
Model: FACSAria
Location: United States, New Jersey
Negotiable
-
Quick Look
Device: Cytometer
Manufacturer: Becton Dickinson
Model: FACS Vantage SE
Manufacturer: Becton Dickinson
Model: FACS Vantage SE
Location: Germany, Baden-Wurttemberg
Rating: 90%
Rating: 90%
Negotiable
2002
Quick Look
Device: Cytometer
Manufacturer: Becton Dickinson
Model: FACSCalibur
Manufacturer: Becton Dickinson
Model: FACSCalibur
Location: United States, Georgia
Negotiable
-
Quick Look
Device: Cytometer
Manufacturer: Becton Dickinson
Model: FACScan
Manufacturer: Becton Dickinson
Model: FACScan
Location: Canada, Ontario
24,900
-
Cytometer may also be referred to as :
Impedance Tester | Impedance Scanning System | Electrical Impedance Cytometer | Coulter Cytometer | Coulter Cell Counter | Impedance System | Reticulocyte Analyzer, Automated | Cytometer, Flow, Clinical Laboratory | Cell SorterTips for buying Cytometer
- Facilities should evaluate their requirements and chose a impedance tester based on them. Coulter cytometers provide various applications - some optional and should be considered according to the needs of a specific facility.
- Flow cytometers should come equipped to perform immunophenotyping.
- The number of colors used in the analysis determines the wavelength requirements for flow cytometers. When working with 2 or 3 colors, a wavelength of 488 nm is required. A wavelength near 560 or 640 nm is preferred when working with 4 or 6 colors.
- The preferred Coulter cytometers are those that can detect 4 colors. Analysis of 6 colors should be considered optional.
- Another impedance tester feature which should be considered optional is cell sorting. Facilities need to determine if this is a required capability for them, either immediately or in the future.
- Manufacturers should provide free instruction for these devices. The flow cytometer operation requires special training. To become proficient, users require additional training and frequent operation of the instrument.
- In some medical facilities, there are dedicated technologists for flow cytometry measurement.
- When purchasing flow cytometers or Coulter cytometers, facilities must communicate with physicians to determine how the results will be used and what tests should be performed, and should also look into personnel requirements.
- Cost of these impedance tester units depends on computer hardware and software, available applications on the unit, and the inclusion of automatic sample preparation units and other accessories.
- Facilities can buy reagents from many suppliers, and it is generally not necessary to standardize the manufacturer of the flow cytometer and reagents since flow cytometers are open-platform instruments.
- Other factors to consider before purchasing a Coulter cytometer unit include: computer and printer options, DNA software options, immuno-fluorescence, and features such as biohazard containment and refrigeration.
Read more valuable tips on the Medical Equipment Buying Guide by MedWOW >>



















