MedWOW / Medical Equipment / Clinical Engineering Equipment / ECG Tester / Fluke Biomedical / 215A Patient Simulator
Used ECG Tester - Fluke Biomedical - 215A Patient Simulator
Item 834317123
Are you the Seller of this medical device/part? Log In for more options.

| Status: | Open |
| Item type: | Complete System |
| Category: | Clinical Engineering |
| Device: | ECG Tester |
| Manufacturer: | Fluke Biomedical |
| Model: | 215A Patient Simulator |
| Condition: | As is |
| Location: | United States, Vermont |
| Availability: | Immediate |
| Quantity: | 1 available |
| Unit Price: | Negotiable |
![]() | Contact the Seller | ![]() |
Item Description
DNI Nevada 215A Patient Simulator PECIFICATIONS:Case:High impact plasticPower:9 V alkaline battery or battery eliminator(115 V or 230 V available; please specify)ECG General:Lead Configuration: 12-lead ECG with nine independent outputs for each signal lead referenced to RLOutput Update Rate: 2.0 msOutput Impedance: 1000W to RL1-volt Output: Lead II @ 1 V peakAmplitude Accuracy: +/- 5% 2 Hz square wave @ 1.0 mV p-p (Lead II)Normal Sinus Rhythm:Rates: 30, 60, 80, 120, 160, 200, 240, & 300 BPMAmplitudes: 0.5, 1.0, 1.5, 2.0 mV (Lead II)St Segment Steps: 0.05, 0.1, 0.15, 0.2, 0.5, & 0.8 mVAxis Deviation: Normal, horizontal, and verticalPediatric ECG: 40 ms R-Wave widthECG Performance:Square Wave: 2 Hz @ 1.0 mV bipolarPulse: 4.0 s @ 1.0 mVSine Waves: 10, 40, 50, 60, & 100 Hz @ 1.0 mVTriangle Wave: 2 Hz @ 3 mVArrhythmias:Selections: 45 total Ventricular, Supraventricular, Premature, Conduction, and PacemakerBase Rhythm: 80 BPM, 1.0 mV/Lead IIPacemaker Spike Duration: 2.0 msPacemaker Spike Amplitude: 4.8 mV +/- 5% Lead IIOutput Connectors:High Level: 0.25" standard phone jackLow Level: 10 AHA (American Heart Association) or European color-coded binding posts; please specify.Compatible with disposable snaps, banana plugs, and 3.2/4.0 mm electrodesTemperature:Channel One: Fixed at 37 degrees?C / 98.6 degrees?FChannel Two: 30 degrees C / 86 degrees F, 37 degrees C / 98.6 degrees?F, 40 degrees C / 104 degrees FTemp Probe Compatibility: 400/700 YSI seriesAccuracy: +/- 0.25??degreesCArtifact:ECG: 50 Hz, 60 Hz, muscle and baseline wander. Any single artifact can be added to the ECG selection at three different levels to all or any single signal lead.BP/Respiration: Two pressure values in phase with respiration can be injected into all BP channels. Arterial and LV waveforms are modulated at the selected respiratory rate. All right heart waveforms have the respiration offset signal added to the output.Respiration:Normal Physiological Simulation- Baseline Impedances: 500W & 1000W- Impedance Variations: 0, 0.1, 0.2, 0.5, 1.0, & 3.0 W- Rates: 15, 20, 30, 40, 60, & 120 BrPM- Apnea: Continuous, momentary, 12 & 32 seconds- Ventilator Simulation: Rate is 40 BrPM @ 3.0W- Output Configuration: Lead I, Lead II & RL-LLDefibrillator Training:Emergency 1: Normal Sinus Rhythm (NSR) with PVC activity terminating into V-FIB.Emergency 2: NSR with a run of 5 PVCs terminating into V-FIB.Cardioversion: Atrial fibrillation is output until defibrillator is discharged, at which point conversion to NSR will occur if properly synchronized with the R-Wave. If the discharge is not synchronized, the ECG output will degrade to V-FIB. You must then perform emergency defibrillation to achieve conversion to NSR.Blood Pressure (3 channels):Input/Output Impedance: 300WExciter Input Voltage Range: 2 to 10 V / DC to 4 kHzTransducer Sensitivity: 5 to 40 m V/V/mmHgLevel Accuracy: 1% of range + 1% of setting + 1 countCalibrated Rate: 10 msWaveform Update Rate: 10 msBP Selections- Dynamic: arterial, left ventricle, right ventricle, pulmonary artery, pulmonary wedge- Static: BP1, 0 to 300 mmHg; BP2, 0 to 30 mmHg; BP3, none.Arrhythmia Selections:Supraventricular- Atrial Fibrillation 1 & 2- Atrial Flutter- Sinus Arrhythmia- Missed Beat 80 BPM and 120 BPM- Paroxysmal Atrial Tachycardia- Nodal- Supraventricular TachycardiaPremature Beats- Atrial (PAC)- Nodal (PNC)- PVC-1, 2 (Standard, early, R on T)- Multifocal PVCsConduction Defects- First Degree- Second Degree Types 1 & 2- Third Degree- Right Bundle Branch Block- Left Bundle Branch BlockVentricular Rhythms- PVCs 6/minute- PVCs 12/minute- PVCs 24/minute- Frequent Multifocal 24/minute- Bigeminy- Trigeminy- Pair PVCs- Run of 5 PVCs- Run of 11 PVCs- Ventricular Tachycardia- V-Fibrillation (fine/coarse)- Dying Heart Complex (EMD)- AsystolePacemaker- Asynchronous- Demand with frequent sinus beat- Demand with occasional sinus beat- AV Sequential- Non-capture- Non-functionDimensions:7.5 in L x 5.4 in W x 1.8 in H(19 cm L x 13.7 cm W x 4.6 cm H)Weight:2 lb (0.9 kg) WB438
Sale Information
| Payment Packaging Payment methods: Bank Transfer Advance payment percentage: 100% The item is not packed Inspection Seller allows inspection of item? Yes Available for inspection from: Immediate Warranty Period: 1 Month Warranty type: Labor & Material |
All item information on this page has been supplied by seller and MedWOW cannot guarantee its accuracy.
Didn't find the medical device you're looking for? Post a Buying Request
A buying lead is an excellent way to reach worldwide medical equipment sellers!
- Fill in a simple form, giving us details about the medical device you are searching for.
- Receive competitive quotes from global sellers that have the item you are searching for in their inventory.
- Choose the best and most suitable quote for you!
View more ECG Tester devices for sale
Seller details
Location: United States, Vermont
Business type: Broker
Learn More About This Seller
![]() | Get a D&B Report >> |
Track this Item
Required quantity
Quantity available: 1
Please enter the quantity you would like to purchase:
Quantity must be between 1 - 1
Please select your choice
Popular Searches
Use of this website constitutes acceptance of the MedWOW User Agreement and Privacy Policy.
© 2012 All rights reserved, MedWOW Ltd. Global online marketplace for buying and selling used medical equipment and medical equipment parts.






