Used ECG Tester - Fluke Biomedical - PS420
Item 294306868
Are you the Seller of this medical device/part? Log In for more options.

| Status: | Open |
| Item type: | Complete System |
| Category: | Clinical Engineering |
| Device: | ECG Tester |
| Manufacturer: | Fluke Biomedical |
| Model: | PS420 |
| Condition: | As is |
| Location: | United States, Vermont |
| Availability: | Immediate |
| Quantity: | 1 available |
| Unit Price: | Negotiable |
![]() | Contact the Seller | ![]() |
Item Description
Fluke PS420 Multi-Parameter Patient Simulator Accessories: Operator Manual, Battery Eliminator, Calibration CertificatePS420 Multiparameter Patient SimulatorThe PS420 Patient Simulator is a handheld, high-performance simulator for testing patient monitors.Small enough to fit in a pocket, the handy PS420 features a wide variety of simulation capability, including a full range of ECG, respiration, blood pressure, temperature and cardiac output conditions. The tool includes 12-lead ECG, two-channel blood pressure simulation, 35 arrhythmia selections, pacemaker simulation as well as adult and pediatric normal sinus rhythms.For convenient use, labeled hot keys on the keypad guide users to the most common settings.FEATURES:Compact, lightweight, pocketsizeLabeled hot keys for common settings12-lead ECGRespiration and temperature selectionTwo-channel blood pressure simulationOptional cardiac outputAdult and pediatric normal sinus rhythms35 arrhythmia selectionsECG performance waveformsST segment levelsECG artifactPacemaker simulationRS232 serial port for computer controlBattery operatedTECHNICAL SPECIFICATIONS:ECG:Normal Rate: 80BPMECG Amplitudes: 0.5mv, 1mv, 1.5mv, 2mvOutput Impedance: 500, 1000, 1500, and 2000 ohms for Leads I, II, IIIHigh-Level Output: 1000x Lead IISelectable Rates: 30 - 300 bpmAccuracy: +/- 1%ECG Waveform Selections: adult or pediatric ECG WaveformECG PERFORMANCE WAVEFORMS:Square Wave: 2.0Hz, 0.125 HzPulse: 30, 60, 120 bpm, 60 mS pulse widthSine Waves: 0.5, 4.0, 10, 40, 50, 60, (1mv Amplitude, lead II)Triangle Wave: 2.0 HzST SEGMENT ANALYSIS:Elevated or depressed: -0.8mV to +0.8mV in 1mV stepsARRYTHMIA SELECTIONS:PREMATURE BEATSAtrial (PAC)Nodal (PNC)PVC1 LV FocusPVC1 Early LV FocusPVC1 R on T LV FocusPVC2 RV FocusPVC2 Early RV FocusPVC2 R on T RV FocusMULTIFOCAL PVC'sSupraventricularAtrial Fibrillation (coarse)Atrial Fibrillation (fine)Atrial FlutterSinus ArrhythmiaMissed BeatAtrial TachycardiaNodalSupraventricular TachycardiaVENTRICULAR RHYTHMS:PVCs 6/minutePVCs 12/minutePVCs 24/minuteFrequent MultifocalBigeminyTrigeminyPair PVCsRun 5 PVCsRun 11 PVCsVentricular TachycardiaVentricular Fibrillation (coarse)Ventricular Fibrillation (fine)AsystoleCONDUCTION DEFECTS:First degree heart blockSecond degree heart blockThird degree heart blockRight bundle branch blockLeft bundle branch blockRESPIRATION:Baseline Impedance: 500, 1000, 1500, 2000 ohms, Leads I, II, and IIILead Selections: LL or LAImpedance Variations: 3, 1, 0.5, and 0.2 ohmsAccuracy: +5%Rates: 15, 20, 30, 40, 60, 80, 100,120, and 0 BPM for ApneaAccuracy: +2%Apnea: 12 seconds, 22 seconds, 32 seconds, and continouosTEMPERATURE:Compatibility: YSI 400/700 SeriesTemperature: 86, 95, 98.6, 104, 107.6 F degrees (30, 35, 37, 40, 42 C degrees)Temperature Simulation Accuracy: +0.25 C degreesPACEMAKER:Pacer Spike Amplitude: 2, 4, 8, and 10mV in Lead IIAccuracy: +5%, lead IIPacer Spike Duration: 0.1, 0.5, 1, 1.5, 2 msAccuracy: +5%Selections: Asynchronous Pacemaker, Pacer Non-Function, Pacer Non-Capture, Demand Occasional Sinus, Demand Frequent Sinus, AV SequentialBLOOD PRESSURE CHANNELS:Dynamic BP waveforms are synchronized with normal sinus rhythm rates and track arrhythmia selections.Input/Output Impedence: 350 OhmsLevel Accuracy: +1%, +1 mmHgExciter Input Limit: + 10VExciter Input Frequency Range: DC to 4000 HzTransducer Sensitivity: 5 or 40 uV/V/mmHgCalibrated Rate: 80 bpm normal sinus rhythmStatic Levels BP1: -10, 0, 50, 100, 150, 200, 250 mmHgStatic Levels BP2: -10, 0, 80, 160, 240, 320, 400 mmHgP1 Channel SelectionsArterial: 120/80Radial artery: 120/80Left ventricle: 120/00Right ventricle: 25/00P2 Channel SelectionsArterial: 120/80Radial artery: 120/80Left ventricle: 120/00Right atrium (Central Venous): 15/10Right ventricle: 25/00Pulmonary artery: 25/10Pulmonary wedge: 10/2Left atrium: 14/4RS-232RS-232 bi-directional interface 9600 BaudPower9 V alkaline batteryDimensions6.1'' x 3.7'' x 1.3'' (15.6 cm x 9.4 cm x 3.4 cm)Weight0.9 lb (0.4 kg) WB433
Questions and Answers Regarding this Item ![]() |
| Question | Answer |
| General: Did the device perform according to manufacturer specifications just before dismantling? | Awaiting Confirmation |
| General: Is the device under confiscation? | Awaiting Confirmation |
| General: Is the device mortgaged? | Awaiting Confirmation |
| General: Is the refurbishing process accomplished by the original manufacturer or its authorized agent? | Awaiting Confirmation |
| General: Frequency | Awaiting Confirmation |
| General: Is the device still installed? | Awaiting Confirmation |
| General: What is the date of refurbishing? | Awaiting Confirmation |
| General: Are you the owner of the device? | Awaiting Confirmation |
| General: Are there any visual or non visual damages? | Awaiting Confirmation |
| General: Power supply - phase | Awaiting Confirmation |
| General: Power supply - Volts range | Awaiting Confirmation |
| General: Does the price include system crating? | Awaiting Confirmation |
| General: Hardware / Software? | Awaiting Confirmation |
| Manuals & Documentation: Is there an operation manual? | Awaiting Confirmation |
| Manuals & Documentation: Are there purchasing documents of the device? | Awaiting Confirmation |
| Manuals & Documentation: Does it have all labels according to manufacturer's specification? | Awaiting Confirmation |
| Manuals & Documentation: Is there a calibration and adjustment file? | Awaiting Confirmation |
| Manuals & Documentation: Is there a CCF - Customer Complaints File? | Awaiting Confirmation |
| Manuals & Documentation: Is there a maintenance service logbook? | Awaiting Confirmation |
| Manuals & Documentation: Is there a log of repair parts? | Awaiting Confirmation |
| Service & Warranty: Can you provide service and application support for this Device? | Awaiting Confirmation |
| Service & Warranty: Was the system under T & M service? | Awaiting Confirmation |
| Service & Warranty: Was the service given by the manufacturer? | Awaiting Confirmation |
| Service & Warranty: Was the service given by third party? | Awaiting Confirmation |
| Service & Warranty: Is there a warranty period after installation? | Awaiting Confirmation |
Sale Information
| Payment Packaging Payment methods: Bank Transfer Advance payment percentage: 100% The item is not packed Inspection Seller allows inspection of item? Yes Available for inspection from: Immediate Warranty Period: 1 Month Warranty type: Labor & Material |
All item information on this page has been supplied by seller and MedWOW cannot guarantee its accuracy.
Didn't find the medical device you're looking for? Post a Buying Request
A buying lead is an excellent way to reach worldwide medical equipment sellers!
- Fill in a simple form, giving us details about the medical device you are searching for.
- Receive competitive quotes from global sellers that have the item you are searching for in their inventory.
- Choose the best and most suitable quote for you!
View more ECG Tester devices for sale
Seller details
Location: United States, Vermont
Business type: Broker
Learn More About This Seller
![]() | Get a D&B Report >> |
Track this Item
Required quantity
Quantity available: 1
Please enter the quantity you would like to purchase:
Quantity must be between 1 - 1
Please select your choice
Popular Searches
Use of this website constitutes acceptance of the MedWOW User Agreement and Privacy Policy.
© 2012 All rights reserved, MedWOW Ltd. Global online marketplace for buying and selling used medical equipment and medical equipment parts.







