New & Used Electrosurgical Unit, Martin
Market Value Calculator
Applied Filters
Model
Continent
Condition
Price Range (USD)
Seller's Business Type
- Complete Systems (8)
Item Details
Seller details
Item Price (USD)
Year manufactured
Quick Look
Device: Electrosurgical Unit
Manufacturer: Martin
Model: MD 60
Manufacturer: Martin
Model: MD 60
Location: Poland, Warminsko
Business type: Importer
Business type: Importer
913
-
Quick Look
Device: Electrosurgical Unit
Manufacturer: Martin
Model: Elektrotom 400
Manufacturer: Martin
Model: Elektrotom 400
Location: Germany, Hamburg
Business type: Broker
Business type: Broker
Negotiable
-
Quick Look
Device: Electrosurgical Unit
Manufacturer: Martin
Model: System 2000
Manufacturer: Martin
Model: System 2000
Location: Germany, Hamburg
Business type: Broker
Business type: Broker
Negotiable
-
Quick Look
Device: Electrosurgical Unit
Manufacturer: Martin
Model: System 2000
Manufacturer: Martin
Model: System 2000
Location: Germany, Hamburg
Business type: Broker
Business type: Broker
Negotiable
-
Quick Look
Device: Electrosurgical Unit
Manufacturer: Martin
Model: ME 82
Manufacturer: Martin
Model: ME 82
Location: Germany, Bavaria
Business type: Dealer
Rating: 93%
Business type: Dealer
Rating: 93%
1,602
-
Quick Look
Device: Electrosurgical Unit
Manufacturer: Martin
Model: Elektrotom 300-BF
Manufacturer: Martin
Model: Elektrotom 300-BF
Location: Germany, North Rhine-Westphalia
Business type: Dealer
Rating: 93%
Business type: Dealer
Rating: 93%
1,774
-
Quick Look
Device: Electrosurgical Unit
Manufacturer: Martin
Model: ME 81
Manufacturer: Martin
Model: ME 81
Location: United Kingdom, Hampshire
Business type: Refurbishing Company
Rating: 96%
Business type: Refurbishing Company
Rating: 96%
1,894
-
Quick Look
Device: Electrosurgical Unit
Manufacturer: Martin
Model: ME 400
Manufacturer: Martin
Model: ME 400
Location: Belgium, Brussels
Business type: Exporter
Business type: Exporter
Negotiable
-
Electrosurgical Unit may also be referred to as :
Endometrial Ablation System | ESU | Hyfrecator | Malis Coagulator | Surgical Diathermy | Surgical Unit | Electrosurgical Unit, Argon-Enhanced Coagulation | Electrosurgical Unit, General Purpose | Electrosurgical Generator | Electrosurgery Unit | Electrosurgery Generator | Diathermy Unit, Surgical | Diathermy Unit | Coagulator, Electrosurgical | BovieTips for buying Electrosurgical Unit
-
These units should come with a solid-state generator, with a typical frequency range of 0.3 to 1 MHz. They should have an isolated monopolar output, a hand switch, a footswitch, and bipolar output.
-
The output power for monopolar cutting should not exceed 300 W, and the open circuit voltage should not exceed 2,000 peak-to-peak volts; these values apply in general-purpose use.
-
For coagulation, the output and open circuit voltage should not exceed 120 W and 6,000 peak-to-peak volts, respectively. Bipolar mode should use no more than 50 W and 300 peak-to-peak volts.
-
Units should include the following: a return electrode contact quality monitor, independent output, visual and audible activation indicators, alarm capable of volumes higher than 45 dB at one meter, power-setting display and convection or fan cooling system.
-
Argon-enhanced units should have a flow range of 0 to 10 L/min, a tank capacity of more than 1,200 L (42 ft3), and a low-pressure alarm; the device should include an alarm capable of volumes higher than 45 dB at one meter.
-
There are numerous designs of electrosurgical units, and facilities should base their comparisons among devices according to characteristics, usefulness of features, safety, and reliability - all of these affect clinical performance.
-
Users who are considering which argon-enhanced coagulation system to purchase, should determine whether they wish to expand their current electrosurgical system with a compatible argon module or they get a new one with an integral argon unit.









