Parts: Electrosurgical Unit
![]() | Medical Part Finder | ![]() | Are you looking for a specific medical part, and you can't find it anywhere? We can find it for you, quickly and easily! | Go to Part Finder >> |
- Complete Systems (590)
- Parts (21)
Quick Look
Manufacturer: Mitek
Model: VAPR
Name / Number: 225201 / Slide Effect Electrode
Business type: Refurbishing Company
Rating: 100%
Quick Look
Manufacturer: Aaron Bovie
Model: Aaron A950
Name / Number: utton Power Control Pencil / A900 And 950 -3
Business type: Exporter
Quick Look
Manufacturer: Valleylab
Model: Force 300
Name / Number: Cart
Business type: Service Company
Quick Look
Manufacturer: Aaron Bovie
Model: Bovie IDS-300
Name / Number: BV-1253
Business type: Dealer
Quick Look
Manufacturer: Valleylab
Model: LigaSure
Name / Number: FOOTPEDAL
Business type: Dealer
Rating: 95%
Quick Look
Manufacturer: Depuy
Model: VAPR
Name / Number: Wand
Business type: Refurbishing Company
Rating: 100%
Quick Look
Manufacturer: Codman
Model: CMC II
Business type: Dealer
Quick Look
Manufacturer: ArthroCare
Model: ATLAS
Name / Number: Controller
Business type: Broker
Quick Look
Manufacturer: Olympus
Model: UES-40
Name / Number: Monopolar Foot Switch
Business type: Broker
Quick Look
Manufacturer: Ethicon Endo-Surgery
Model: Pegasys Electrosurgical Generator
Name / Number: Foot Switch / GEN03
Business type: Broker
Quick Look
Manufacturer: Mitek
Model: VAPR 3
Name / Number: Foot Switch
Business type: Broker
Quick Look
Manufacturer: Valleylab
Model: NS2000
Name / Number: Footswitch
Business type: Broker
Quick Look
Manufacturer: ArthroCare
Model: System 2000
Name / Number: Footswitch / H2000
Business type: Refurbishing Company
Rating: 100%
Quick Look
Manufacturer: Valleylab
Model: Force 1C
Name / Number: Monopolar Foot Switch / E6008
Business type: Refurbishing Company
Rating: 100%
Quick Look
Manufacturer: Ethicon Endo-Surgery
Model: Harmonic Scalpel Generator G-110
Name / Number: G-110 Footswitch and Cable / GEN03
Business type: Refurbishing Company
Rating: 100%
| Current Manufacturer / Model Name | Alternative Manufacturer / Model Name |
|---|---|
| Mitek / VAPR 3 | Depuy / VAPR 3 |
| Mitek / VAPR | Depuy / VAPR |
Electrosurgical Unit may also be referred to as :
Endometrial Ablation System | ESU | Hyfrecator | Malis Coagulator | Surgical Diathermy | Surgical Unit | Electrosurgical Unit, Argon-Enhanced Coagulation | Electrosurgical Unit, General Purpose | Electrosurgical Generator | Electrosurgery Unit | Electrosurgery Generator | Diathermy Unit, Surgical | Diathermy Unit | Coagulator, Electrosurgical | BovieIf you have not found your required medical part at the list above, our suppliers can offer you the following medical parts (6):

Device: Electrosurgical Unit
Manufacturer: Olympus
Model: UES-30
Name / Number: Cable / A00012A

Device: Electrosurgical Unit
Manufacturer: Linvatec Hall
Model: Arthrotome
Name / Number: Console / 5039-02

Device: Electrosurgical Unit
Manufacturer: ArthroCare
Model: ATLAS
Name / Number: Controller / 10435-01

Device: Electrosurgical Unit
Manufacturer: Valleylab
Model: LigaSure
Name / Number: Dual Foot Pedal / IPX8

Device: Electrosurgical Unit
Manufacturer: Valleylab
Model: Force 40
Name / Number: ESU / R3A 1679S

Device: Electrosurgical Unit
Manufacturer: Ethicon Endo-Surgery
Model: Harmonic Scalpel Generator G-110
Name / Number: G-110 Generator Cart / GEN02
Tips for buying Electrosurgical Unit Parts
- These units should come with a solid-state generator, with a typical frequency range of 0.3 to 1 MHz. They should have an isolated monopolar output, a hand switch, a footswitch, and bipolar output.
- The output power for monopolar cutting should not exceed 300 W, and the open circuit voltage should not exceed 2,000 peak-to-peak volts; these values apply in general-purpose use.
- For coagulation, the output and open circuit voltage should not exceed 120 W and 6,000 peak-to-peak volts, respectively. Bipolar mode should use no more than 50 W and 300 peak-to-peak volts.
- Units should include the following: a return electrode contact quality monitor, independent output, visual and audible activation indicators, alarm capable of volumes higher than 45 dB at one meter, power-setting display and convection or fan cooling system.
- Argon-enhanced units should have a flow range of 0 to 10 L/min, a tank capacity of more than 1,200 L (42 ft3), and a low-pressure alarm; the device should include an alarm capable of volumes higher than 45 dB at one meter.
- There are numerous designs of electrosurgical units, and facilities should base their comparisons among devices according to characteristics, usefulness of features, safety, and reliability - all of these affect clinical performance.
- Users who are considering which argon-enhanced coagulation system to purchase, should determine whether they wish to expand their current electrosurgical system with a compatible argon module or they get a new one with an integral argon unit.