Parts: Electrosurgical Unit, Valleylab, LigaSure
Applied Filters
Continent
Condition
Manf. Year From
Manf. Year Until
Price Range (USD)
Seller's Business Type
![]() | Medical Part Finder | ![]() | Are you looking for a specific medical part, and you can't find it anywhere? We can find it for you, quickly and easily! | Go to Part Finder >> |
- Complete Systems (8)
- Parts (7)
Item Details
Seller details
Item Price (USD)
Year manufactured
Quick Look
Device: Electrosurgical Unit
Manufacturer: Valleylab
Model: LigaSure
Name / Number: Footswitch / LF0500
Manufacturer: Valleylab
Model: LigaSure
Name / Number: Footswitch / LF0500
Location: United States, New York
Rating: 88%
Rating: 88%
650
2008
Quick Look
Device: Electrosurgical Unit
Manufacturer: Valleylab
Model: LigaSure
Name / Number: Footswitch / LS0300
Manufacturer: Valleylab
Model: LigaSure
Name / Number: Footswitch / LS0300
Location: United States, New York
Rating: 88%
Rating: 88%
600
2007
Quick Look
Device: Electrosurgical Unit
Manufacturer: Valleylab
Model: LigaSure
Name / Number: LS3112
Manufacturer: Valleylab
Model: LigaSure
Name / Number: LS3112
Location: Cyprus
650 
2011
Quick Look
Device: Electrosurgical Unit
Manufacturer: Valleylab
Model: LigaSure
Name / Number: FOOTPEDAL
Manufacturer: Valleylab
Model: LigaSure
Name / Number: FOOTPEDAL
Location: United States, Kentucky
Rating: 95%
Rating: 95%
Negotiable
-
Quick Look
Device: Electrosurgical Unit
Manufacturer: Valleylab
Model: LigaSure
Manufacturer: Valleylab
Model: LigaSure
Location: Cyprus
435 
-
Quick Look
Device: Electrosurgical Unit
Manufacturer: Valleylab
Model: LigaSure
Manufacturer: Valleylab
Model: LigaSure
Location: Cyprus
435 
-
Quick Look
Device: Electrosurgical Unit
Manufacturer: Valleylab
Model: LigaSure
Manufacturer: Valleylab
Model: LigaSure
Location: Cyprus
435 
-
Electrosurgical Unit may also be referred to as :
Endometrial Ablation System | ESU | Hyfrecator | Malis Coagulator | Surgical Diathermy | Surgical Unit | Electrosurgical Unit, Argon-Enhanced Coagulation | Electrosurgical Unit, General Purpose | Electrosurgical Generator | Electrosurgery Unit | Electrosurgery Generator | Diathermy Unit, Surgical | Diathermy Unit | Coagulator, Electrosurgical | BovieTips for buying Electrosurgical Unit Parts
- These units should come with a solid-state generator, with a typical frequency range of 0.3 to 1 MHz. They should have an isolated monopolar output, a hand switch, a footswitch, and bipolar output.
- The output power for monopolar cutting should not exceed 300 W, and the open circuit voltage should not exceed 2,000 peak-to-peak volts; these values apply in general-purpose use.
- For coagulation, the output and open circuit voltage should not exceed 120 W and 6,000 peak-to-peak volts, respectively. Bipolar mode should use no more than 50 W and 300 peak-to-peak volts.
- Units should include the following: a return electrode contact quality monitor, independent output, visual and audible activation indicators, alarm capable of volumes higher than 45 dB at one meter, power-setting display and convection or fan cooling system.
- Argon-enhanced units should have a flow range of 0 to 10 L/min, a tank capacity of more than 1,200 L (42 ft3), and a low-pressure alarm; the device should include an alarm capable of volumes higher than 45 dB at one meter.
- There are numerous designs of electrosurgical units, and facilities should base their comparisons among devices according to characteristics, usefulness of features, safety, and reliability - all of these affect clinical performance.
- Users who are considering which argon-enhanced coagulation system to purchase, should determine whether they wish to expand their current electrosurgical system with a compatible argon module or they get a new one with an integral argon unit.
Read more valuable tips on the Medical Equipment Buying Guide by MedWOW >>