Parts: Laser Blood Flow Detector

loupe Medical Part Finder Search for part Are you looking for a specific medical part, and you can't find it anywhere?
We can find it for you, quickly and easily!
Go to Part Finder >>
 
 
 
 
 
Item Details
Seller details
Item Price (USD)
Year manufactured

Laser Blood Flow Detector may also be referred to as :

TachoMeter | HemotachoMeter | Blood Flowmeter | Blood Flow Detector | Laser Blood Flowmeter

If you have not found your required medical part on the above list, our suppliers can additionally offer you the following medical parts (1):

 
Item Details
Actions
PR-434 Needle Probe PR-434

Device: Laser Blood Flow Detector

Manufacturer: Vasamedics

Model: BPM2

Name / Number: PR-434 Needle Probe / PR-434

Request a quote

 

Tips for buying Laser Blood Flow Detector Parts

  1. Laser blood flow meters and blood-flow detectors can be handheld, portable, or tabletop units. Facilities should select the right configuration based on clinician monitoring needs and preference.
  2. Blood-flow detectors and meters should include an on/off indicator, and transducers with different user-selectable transmitting frequencies. The detectors and flow meters should have a range of 2 to 8 MHz.
  3. External speakers with volume control for Doppler analysis should be included with the flow meters. They should also have bi-directional flow indicators, and a transducer mounted on a catheter or probe or integral to a clamp.
  4. Flow meters should have probes with different lumen diameters; frequency response should be user selectable and within a range of 0.5 to 100 Hz and should be user selectable.
  5. A flow meter should remain zeroed and calibrated for at least one day after it was zeroed and calibrated according to the manufacturer's instructions.
  6. In order to provide the required accuracy for the evaluation of blood perfusion, the units should include a fiber optic probe designed for that purpose.
  7. The following data should be specified by the manufacturer: the unit's measurement depth, response time, laser class, wavelength, and power output at probe tip, Doppler-shift frequency range, cable length, and probe-head diameter.
  8. When facilities consider buying probes to be used with blood flow meters, they should look into various factors, such as the length of the vessel that can be exposed, the available space around the vessel, the location of adjacent organs, and the depth of the vessel's location.
  9. Facilities must use probes of the right size and type to obtain accurate results; most manufacturers will try to meet specific needs for probe sizes and accessories although they don't necessarily include it in their usual product lines.
  10. Various output options are offered with these units. These may include headphones, chart recorder, extra output jacks, a printer, and meters.
  11. Other options are available as well, including pneumoplethysmography, strain-gauge plethysmography, photoplethysmography, a carrying case, a remote control, a footswitch, and interfacing capabilities.
  12. The units can be line-powered or battery-powered; battery-powered units should have their battery operating the device for at least two hours. A visible and audible alarm should warn when a battery level falls to the point that may fail the unit to perform satisfactorily.
  13. Rechargeable batteries should require less than 16 hours of recharging after depletion; when there's a need to recharge the battery, a clear indicator should appear.
Read more valuable tips on the Medical Equipment Buying Guide by MedWOW >>