New & Used Laser - Excimer

Market Value Calculator
 
Applied Filters

Manf. Year Until : 2007

  Reset
 
 
 
 
Item Details
Seller details
Item Price (USD)
Year manufactured

Quick Look

 
Device: Laser - Excimer
Manufacturer: AMO (Abbott Medical Optics)
Model: IntraLase
Premium User
Location: United States, Florida
60,000
-

Quick Look

 
Device: Laser - Excimer
Manufacturer: Nidek
Model: EC-5000 EC-5000CXII
Premium User
Location: United States, Florida
Negotiable
-

Quick Look

 
Device: Laser - Excimer
Manufacturer: AMO (Abbott Medical Optics)
Model: IntraLase
Premium User
Location: United States, Florida
100,000
-

Quick Look

 
Device: Laser - Excimer
Manufacturer: Nidek
Model: EC-5000 EC-5000CXII
Premium User
Location: United States, Florida
130,000
2004

Quick Look

 
Device: Vascular Lesion Removal Laser
Manufacturer: Focus Medical
Model: NaturaLight
Premium User
Location: United States, Michigan
Rating: 100%
11,000
This Seller accepts SafeTrade as a payment method
2006

Quick Look

 
Device: Laser - Excimer
Manufacturer: AMO (Abbott Medical Optics)
Model: VISX STAR S4 Custom VSS
Premium User
Location: United States, Florida
115,000
-

Quick Look

 
Device: Vascular Lesion Removal Laser
Manufacturer: Focus Medical
Model: NaturaLight
Premium User
Location: United States, Michigan
Rating: 100%
Negotiable
This Seller accepts SafeTrade as a payment method
2007

Quick Look

 
Device: Laser - Argon
Manufacturer: Esc Sharplan
Model: Derma K
Premium User
Location: United States, Michigan
Rating: 100%
Negotiable
This Seller accepts SafeTrade as a payment method
1999

Quick Look

 
Device: Laser - Excimer
Manufacturer: AMO (Abbott Medical Optics)
Model: IntraLase
Premium User
Location: United States, Florida
125,000
-

Quick Look

 
Device: Laser - Excimer
Manufacturer: Schwind
Model: Esiris
Location: Portugal, Braga
15,350
2000

Quick Look

 
Device: Laser - Excimer
Manufacturer: Alcon Laboratories
Model: LADARVision 4000
Location: United States, Hawaii
30,000
2001

Quick Look

 
Device: Laser - Excimer
Manufacturer: Ziemer Group
Model: Femto LDV
Location: Ireland
22,435
This Seller accepts SafeTrade as a payment method
-

Quick Look

 
Device: Laser - Excimer
Manufacturer: Visx
Model: Star S4
Location: United Kingdom, Cleveland
48,412
This Seller accepts SafeTrade as a payment method
-

Quick Look

 
Device: Laser - Excimer
Manufacturer: Alcon
Model: Allegretto Eye-Q 400
Location: Netherlands, Noord-Brabant
40,000
2002
Page: 1 2 3 4 5

Laser - Excimer may also be referred to as :

Excimer Laser
 

Tips for buying Laser - Excimer

  1. This is the delivered power for the different beams: 3 W for an argon blue-green beam, 1 W for an argon green beam, 1 W for a dye beam, 1.5 W for a krypton green beam, 1.5 W for a krypton yellow beam, 1 W for a krypton red beam, and 1 W for a Nd:YAG beam.
  2. The following lasers should have principal wavelengths of 530-540 nm: argon, dye, krypton, and frequency doubled Nd:YAG lasers.
  3. The requirements of the unit include: single and repeat delivery modes, exposure duration of 0.01 to 2 seconds, repeat time of 0.1 to 2 seconds, a spot diameter of 50 to 1,000 mm, a slit lamp, an intraocular probe, a hand piece, and an indirect ophthalmoscope.
  4. An Nd:YAG laser should use a Q-switched operating mode and a fundamental mode structure; it should have a single pulse of 0.3 to 10 mJ, pulse duration of 4 n/sec, and 1 to 3 pulses per burst.
  5. The spot size should be 10 μm, and the cone angle – 16°. A single pulse should be at 1-2 Hz, and a burst should be at 1 Hz.
  6. Selected energy, shot selection, power output, and shot counter – should all be displayed and controlled by the unit.
  7. The laser should have a joystick beam actuator.
  8. A compatible slit lamp should be used with magnification up to 25× and a working distance of 1,000 mm.
  9. Each unit should have an automatic calibration system and the following accessories: contact lens, co-observation, a television with 35 mm adapter, a head restraint system, and a tonometer.
  10. An excimer laser should have a wavelength of 193 nm, 0-3 W of power output at tissue, 10 mJ per pulse, and an energy density of 150- 200 mJ/cm2; it should have both continuous and pulsed delivery modes, a beam diameter of 1 to 5 mm, a pulse repetition rate of 10 to 200 Hz, and a pulse duration of 10 to 15nsec.
  11. Buyers should expect a unit with a high precision spot delivery system, a computer system, halogen gas cylinders, and 24 months of halogen source useful life.
  12. A diode laser should have a power output on tissue of 1 W, both continuous and pulsed delivery modes, a pulse repetition rate ≤10 Hz, and pulse duration of 50 msec to continuous.
  13. There are units requiring higher voltages and greater current capacity than those available from a standard outlet. If a unit needs an external water source, facilities should locate it above the first floor of an older building, and they may need a booster pump to provide adequate water pressure for cooling.
  14. Facilities are encouraged to submit requests for proposal to several suppliers; they should discuss the important issue of prospective servicing.
  15. Buyers should evaluate whether the laser is adaptable for other types of therapy for which they have a need.
Read more valuable tips on the Medical Equipment Buying Guide by MedWOW >>