Used Linear Accelerator - Varian -  Clinac 600C

Item 144154694

Are you the Seller of this medical device/part? Log In for more options.
Status: Open
Item type: Complete System
Category: Oncology
Device: Linear Accelerator
Manufacturer: Varian
Model: Clinac 600C
Condition: As is
Year manufactured: 1995
Location: United States, Connecticut
Availability: Immediate
Quantity: 1 available
Unit Price: 35,000.00 USD
Contact the Seller
Inspect Before You Buy
Item Description
VARIAN, 600C w/ 2002 BrainLAB M3 MLC Radiosurgery

Description: Varian 600C plus 2002 BrainLab M3 MLC
Stereotactic Radiotherapy
600C Installed June 1995

Console Software V. 5.4

TOTAL PRICE ONLY $35,000 FOR DEINSTALLED UNIT-- AN UNHEARD OF PRICE FOR A UNIT WHICH INCLUDES THE TOTAL DEINSTALATION COST &
THE COST OF ORIGINAL BASE FRAME REMOVAL WITH THE BASE FRAME INCLUDED IN SALE
--READY TO LOAD LINAC & BASE FRAME ON TRUCK along with 2002 BRAINLAB M3 MLC: Being sold w/ 2002 BrainLAB M3 stereotactic unit
Photon Energy: 6 MV
Beam Hours: <1,300
Dual jaws
ETR Couch
Unit in good working order at time of deinstallation
De-installed Base Frame [Conventional] included
Call to discuss details


SYSTEMS BROKERED have been CRATED and SHIPPED to SATISFIED CLIENTS AT CANCER CENTERS in
INDONESIA, TURKEY, BRAZIL, COLOMBIA, URUGUAY, RUSSIA, and other locations, and to therapy centers, and service companies in the US

REFERENCES AVAILABLE UPON REQUEST.

The m3 high-resolution multileaf collimator, with its fine 3mm leaves at isocenter, has revolutionized radiosurgery by introducing conformal treatments that tailor the dose to the shape of the tumor.

The m3 enables the delivery of superior homogeneous dose distributions with a steep dose gradient – an essential requirement for SRS treatments.

The leaves of the m3 are automatically placed around the target for all beam angles with the desired margin. Risk objects may be automatically protected by the leaves, with manual adjustments able to be made at any time.

Reduced irradiation of normal tissue and the homogeneous dose distribution within the PTV contributes to superior and more efficient patient care.

m3 SETUP
The detachable 'plug and treat' design of the m3 high-resolution multileaf collimator allows fast and easy slide-on attachment to almost any existing linac accessory mount, aided by the storage trolley and with the gantry at the 180° position.

Once m3 is physically mounted to the linear accelerator, the electrical and date connection is immediate.

INTEGRATED SAFETY
The m3 is the only solution fully integrated with Varian accelerators. It communicates with Varian C-Series Clinacs as if it were an internal part of the accelerator, providing superior Clinac safety interlocks, reliability and capabilities such as Dynamic Conformal Arcs and Dynamic IMRT.

Steep dose fall-off - a fundamental requirement for radiosurgery

Multileaf collimators with a leaf thickness of 10 mm are optimized for standard radiotherapy. For stereotactic treatments, a steep dose fall-off is required to protect normal tissue and, in particular, critical structures from high doses.

To accommodate a higher resolution dose delivery, new multileaf collimator designs with 5 mm thick leaves allow the delivery of fractionated stereotactic radiotherapy, but are not generally acceptable for single fraction radiosurgery where special requirements have been defined by the AAPM (1).

The steepness of the dose gradient in radiosurgery is a function of beam geometry and beam penumbra.

Care must be taken to minimize penumbra of the collimator system because the larger the beam penumbra, the shallower the dose fall-off (Figure 1).

For radiosurgery, the recommended limit for dose gradient in the beam penumbra (from 80% to 20%) is greater than or equal to 60%/3 mm (Figure 1).

Fig. 2* [See webpage link supplied for Figures]

Most commercially available multileaf collimators have a penumbra specification from 4 to 8 mm. The m3 with its 3 mm-thin leaves has an effective penumbra of less than 3 mm for all SRS field sizes and meets all SRS requirements (Figure 2).

Thus, the dose can be tailored according to the shape of the lesion, while sparing large amounts of normal healthy tissue.

*An irregular field shape formed from diagonal, straight field edges. Measured 80%, 50% and 20% isodose lines are indicated. A sinusoidal variation in the isodose lines occurs due to the stepping effect between leaf ends and is smallest where the field is formed by the 3 mm thin leaves. Tangents between the 80% and 20% isodose lines show an increasing effective penumbra with increasing leaf thickness.

REFERENCES

AAPM Report No. 54, Stereotactic Radiosurgery, Report of Task Group 42, American Institute of Physics, June 1995 Pike, Podgorsak, et. al., 'Dose distributions in radiosurgery' Medical Physics, Mar/Apr 1990 Cosgrove, et. al., 'Commissioning of a Micro Multi-leaf Collimator and Planning System for SRS.', Radiotherapy & Oncology, (50) 1999

Find your Solution: neurosurgery solutions orthopedic solutions RT/oncology solutions ent solutions spine & trauma solutions integrated OR solutions healthcare IT solutions home print send back m3 High-Resolution Multileaf Collimator
 Questions and Answers Regarding this Item 
 
QuestionAnswer
General: Did the device perform according to manufacturer specifications just before dismantling? Awaiting Confirmation
General: Is the refurbishing process accomplished by the original manufacturer or its authorized agent? Awaiting Confirmation
General: Is the device still installed? Awaiting Confirmation
General: What is the date of refurbishing? Awaiting Confirmation
General: Are you the owner of the device? Awaiting Confirmation
General: Are there any visual or non visual damages? Awaiting Confirmation
General: Power supply - phase Awaiting Confirmation
General: Power supply - Volts range Awaiting Confirmation
General: Does the price include system crating? Awaiting Confirmation
General: Is this system / equipment fully approved by the FDA ? Awaiting Confirmation
General: Is this system / equipment CE marked? Awaiting Confirmation
Manuals & Documentation: Is there an operation manual? Awaiting Confirmation
Manuals & Documentation: Is there a calibration and adjustment file? Awaiting Confirmation
Manuals & Documentation: Is there a CCF - Customer Complaints File? Awaiting Confirmation
Manuals & Documentation: Is there a maintenance service logbook? Awaiting Confirmation
Manuals & Documentation: Is there a log of repair parts? Awaiting Confirmation
Does M3 come with plan software? How much for M3 only?
Sale Information
Payment
Payment methods: Bank Transfer
Advance payment percentage: 10%
Packaging
The item is not packed
Inspection
Seller allows inspection of item? Yes
Available for inspection from: Immediate
 
All item information on this page has been supplied by seller and MedWOW cannot guarantee its accuracy.
Didn't find the medical device you're looking for? Post a Buying Request
A buying lead is an excellent way to reach worldwide medical equipment sellers!
  • Fill in a simple form, giving us details about the medical device you are searching for.
  • Receive competitive quotes from global sellers that have the item you are searching for in their inventory.
  • Choose the best and most suitable quote for you!
Post a Buying Request >>

View more Linear Accelerator devices for sale


Linear Accelerator may also be referred to as: Linear Accelerator, Radiotherapy Unit | IMRT | LINAC
Seller details
Location: United States, Connecticut
Business type: Broker
Learn More About This Seller
Get a D&B Report >>
Buying Toolbox
Track this Item