New & Used Mammography Unit

Market Value Calculator
 
Please Note: Search results for this device do not include the following devices, please select the relevant device if it is of interest to you: Digital Mammography Unit
 
 
 
 
Item Details
Seller details
Item Price (USD)
Year manufactured

Quick Look

 
Device: Digital Mammography Unit
Manufacturer: Siemens
Model: MAMMOMAT 1000
Premium User
Location: Romania, Bucharest
70,684
This Seller accepts SafeTrade as a payment method
2009

Quick Look

 
Device: Mammography Unit
Manufacturer: Hologic
Model: M-IV
Premium User
Location: Japan, Chiba
Negotiable
-

Quick Look

 
Device: Mammography Unit
Manufacturer: GE Healthcare
Model: Senographe DMR
Premium User
Location: Japan, Chiba
7,000
-

Quick Look

 
Device: Mammography Unit
Manufacturer: GE Healthcare
Model: Senographe DMR
Premium User
Location: Japan, Chiba
9,000
-

Quick Look

 
Device: Mammography Unit
Manufacturer: Siemens
Model: MAMMOMAT 3000
Location: Belgium, Flemish Brabent
9,426
This Seller accepts SafeTrade as a payment method
2004

Quick Look

 
Device: Mammography Unit
Manufacturer: Siemens
Model: MAMMOMAT 3
Location: Hungary, Pest
6,000
1994

Quick Look

 
Device: Mobile Mammography
Manufacturer: GE Healthcare
Model: Senographe 800T
Location: United States, Georgia
36,000
This Seller accepts SafeTrade as a payment method
2000

Quick Look

 
Device: Mammography Unit
Manufacturer: Siemens
Model: MAMMOMAT 3000 NOVA
Location: United States, Florida
Negotiable
1999

Quick Look

 
Device: Mammography Unit
Manufacturer: Siemens
Model: Digital Mammomat Novation
Location: Czech Republic, Ustecky
74,063
2006

Quick Look

 
Device: Mammography Unit
Manufacturer: Instrumentarium
Model: Performa
Location: Czech Republic, Ustecky
8,080
2003

Quick Look

 
Device: Mammography Unit
Manufacturer: Planmed
Model: Sophie
Location: Germany, Bavaria
10,100
1999

Quick Look

 
Device: Digital Mammography Unit
Manufacturer: GE Healthcare
Model: Diamond
Location: France, Île-de-France
18,852
This Seller accepts SafeTrade as a payment method
2007

Quick Look

 
Device: Mammography Unit
Manufacturer: Philips
Model: MammoDiagnost
Location: France, Île-de-France
16,159
This Seller accepts SafeTrade as a payment method
2005

Quick Look

 
Device: Mammography Unit
Manufacturer: GE Healthcare
Model: Senographe DMR+
Location: Austria, Lower Ausria
4,990
2002

Quick Look

 
Device: Mammography Unit
Manufacturer: GE Healthcare
Model: Senographe DMR+
Location: France, Île-de-France
8,080
This Seller accepts SafeTrade as a payment method
2004
Page: 1 2 3 4 5
The model & manufacturer of the marked items have changed due to an acquisition between companies, and are also known as:
Current Manufacturer / Model Name Alternative Manufacturer / Model Name
Instrumentarium / Performa GE Healthcare / Performa
Lorad / M-IV Hologic / M-IV

Mammography Unit may also be referred to as :

Radiographic Unit, Mammographic | Xeromammograph | X-ray Mammography | System, X-ray, Mammography | Radiographic Unit, Mammography, Mobile | Mammography Unit | Mammograph | Mammographic Radiographic Unit
 

Tips for buying Mammography Unit

  1. Mammography screening equipment must meet the minimum MQSA requirements for tube outputs, compression performance, position controls, and reproducibility.
  2. Facilities should base their Mammography unit screening purchase decision on life-cycle cost, local service support, discount rates and non-price-related benefits offered by the supplier, and standardization with existing equipment.
  3. Suppliers offer service contracts or service on a time-and-materials basis. This may also be available from a third-party organization. Facilities should carefully consider whether to purchase such a service.
  4. When purchasing a Mammography screening equipment unit, performance and reliability are important factors.
  5. A Mammographic unit high-frequency x-ray generator will help ensure higher efficiency of operation with a minimum of output ripple. It will also need less space than a conventional generator.
  6. Mammography involves a narrow range of tissue thickness, and therefore 1 kV increments and a range of approximately 22 to 35 kV are necessary.
  7. The system should offer at least 500 mAs and an exposure time of 0.1 second or shorter to avoid unnecessary long exposures.
  8. A rotating anode, which has a higher heat capacity than a stationary anode, should be available on the Mammography unit to promote longer x-ray tube life and provide a more consistent x-ray output.
  9. AEC provides the appropriate image optical density and x-ray exposure for breast composition and thickness.
  10. Focal spot sizes should be approximately 0.1-0.3 mm to ensure that micro calcifications as small as 200 µm can be detected.
  11. To clearly image the smallest micro calcifications, an SID of at least 66 cm is needed.
  12. The complexity of the automatic exposure control is the main difference between systems. Some systems control only the exposure time, while more advanced ones control the x-ray spectrum, including the kVp, anode, and filtration. Such systems improve the image quality, especially in larger and denser breasts.
  13. Some manufacturers of Mammography units have developed advanced grids, which are expensive to manufacture but improve the image quality.
  14. Facilities considering the purchase of a stereo tactic biopsy system should consider the number of procedures to be performed and the compatibility with existing Mammographic equipment.
  15. Film-based Mammographic units are not recommended because they do not allow real-time guidance. Instead, both dedicated and add-on systems are equipped with small digital detectors.
  16. Add-on systems may be harder to use because they have more limited motions compared to dedicated mammographic systems. Consequently, most of the differences are a matter of user preference rather than clinical efficacy.
  17. In digital detector performance, detective quantum efficiency is an important factor. DQE is directly related to the signal-to-noise ratio that results between detector input and output. The noise generated by the detector and the spatial resolution contributes to the DQE of the system. To reduce DQE, SNR must be reduced; a recommended DQE is less than 20% at 5 lp/mm.
  18. Another important factor when considering a purchase of a Mammography unit is modulation transfer function. MTF refers to the loss of contrast relative to an x-rayed object. As spatial frequencies in a given image increase, MTF decreases, creating loss of visualization. A 50% MTF at 5 line pairs per millimeter is recommended.
Read more valuable tips on the Medical Equipment Buying Guide by MedWOW >>