MedWOW / Used Medical Parts / Imaging Parts / Mammography Unit
 

Parts: Mammography Unit

loupe Medical Part Finder Search for part Are you looking for a specific medical part, and you can't find it anywhere?
We can find it for you, quickly and easily!
Go to Part Finder >>
 
Please Note: Search results for this device do not include the following devices, please select the relevant device if it is of interest to you: Digital Mammography Unit
 
 
 
 
Item Details
Seller details
Item Price (USD)
Year manufactured

Quick Look

 
Device: Mammography Unit
Manufacturer: Siemens
Model: MAMMOMAT 300
Name / Number: Cassette Holder / 62 78 548 X041E
Premium User
Location: United States, Washington
Rating: 89%
105
This Seller accepts SafeTrade as a payment method
-

Quick Look

 
Device: Mammography Unit
Manufacturer: Siemens
Model: MAMMOMAT 300
Name / Number: 62 78 514 X041E
Premium User
Location: United States, Washington
Rating: 89%
430
This Seller accepts SafeTrade as a payment method
1995

Quick Look

 
Device: Mammography Unit
Manufacturer: Siemens
Model: MAMMOMAT 300
Name / Number: Paddle / 62 58 060 X041E
Premium User
Location: United States, Washington
Rating: 89%
180
-
Page: 1 2 3 4 5

Mammography Unit may also be referred to as :

Radiographic Unit, Mammographic | Xeromammograph | X-ray Mammography | System, X-ray, Mammography | Radiographic Unit, Mammography, Mobile | Mammography Unit | Mammograph | Mammographic Radiographic Unit

If you have not found your required medical part on the above list, our suppliers can additionally offer you the following medical parts (1,193):

 
Item Details
Actions
C808823

Device: Mammography Unit

Manufacturer: GE Healthcare

Model: Senographe 600T FD

Name / Number: C808823

Request a quote

06 Coll Blade 2165415

Device: Mammography Unit

Manufacturer: GE Healthcare

Model: Senographe 800T

Name / Number: 06 Coll Blade / 2165415

Request a quote

1 line fluorescent read out 91717150

Device: Mammography Unit

Manufacturer: GE Healthcare

Model: Senographe DMR

Name / Number: 1 line fluorescent read out / 91717150

Request a quote

100 control panel 2107036

Device: Mammography Unit

Manufacturer: GE Healthcare

Model: Senographe 700T

Name / Number: 100 control panel / 2107036

Request a quote

100 PL1 operator bd 2208296

Device: Mammography Unit

Manufacturer: GE Healthcare

Model: Senographe DMR+

Name / Number: 100 PL1 operator bd / 2208296

Request a quote

100 PL1 operator board 45474413

Device: Mammography Unit

Manufacturer: GE Healthcare

Model: Senographe DMR

Name / Number: 100 PL1 operator board / 45474413

Request a quote

100 PL2 console control bd 2208298

Device: Mammography Unit

Manufacturer: GE Healthcare

Model: Senographe DMR+

Name / Number: 100 PL2 console control bd / 2208298

Request a quote

100 PL2 console control board 4556130

Device: Mammography Unit

Manufacturer: GE Healthcare

Model: Senographe DMR

Name / Number: 100 PL2 console control board / 4556130

Request a quote

100-PL2 console control bd 45561530

Device: Mammography Unit

Manufacturer: GE Healthcare

Model: Senographe DMR

Name / Number: 100-PL2 console control bd / 45561530

Request a quote

10x10 Coll Blade 2165417

Device: Mammography Unit

Manufacturer: GE Healthcare

Model: Senographe 800T

Name / Number: 10x10 Coll Blade / 2165417

Request a quote

Page: 1 2 3 4 5
 

Tips for buying Mammography Unit Parts

Mammography x-ray systems are specially designed to produce radiographic images of the breast. This equipment is assembled of unique mammography parts, customized to produce the best images, with the minimal possible amount of exposure to x-ray radiation.<br /> <br /> The main clinical applications of these systems are: breast cancer screening, staging and grading, and differential diagnosis in symptomatic patients. <br /> <br /> <ol> <li>Most of the mammographs allow magnification views and spot images. In general, mammographs are composed of mammography parts which have special ergonomic requirements, compared to those of the general radiographic systems. </li> <li>A special stereotactic attachment, another critical mammography part, enables the performance of stereotactic biopsy procedures. </li> <li>The previous generation mammographs were all screen-film-types. A limitation of screen-film mammography is the film itself. Once a screen-field mammogram is obtained, it cannot be significantly altered. </li> <li>Contrast loss due to film underexposure, especially of dense glandular-tissues, cannot be regained through film display. </li> <li>The latest mammography equipment features special mammography parts which are integrated, and as a result, digital mammography images can be obtained. Now, when the mammograph is in a digital format, the image can be manipulated in a variety of ways to highlight lesion conspicuity. </li> <li>In addition, image storage, transmission and retrieval can be improved. Digital images can be processed by a computer mammography part and displayed in multiple formats; on film or on a monitor. Computer-aided detection software to assist the radiologist in interpreting the images can also be used to provide a second opinion and improve diagnostic accuracy.</li> <li>Digital mammography images can be obtained either by a full field of view (FFDM – full field digital mammography) a digital detector mammography part, or by using CR cassettes and a CR reader. Also, a small sized digital detector, another integral mammography part, can be incorporated into the film holder device mammography part, for image spotting and as a way of guiding stereotactic biopsies. </li> <li>Small field digital mammography units, are also available as add-on component mammography parts to the older screen-film mammographs. They can be used in conjunction with the mammography part stereotactic attachment. </li> <li>Digital imaging can be processed using sophisticated pattern recognition software, another vital mammography part, and “suspicious” features are highlighted on the image and brought to the attention of the reader. It is necessary to understand that the existing workflow will probably not work at a maximum efficiency once the department has moved to digital imaging. To achieve an efficient workflow, links to a PACS (Picture Archiving and Communications System) must be considered. </li> <li>Reducing patient dosage to levels which are as low as reasonably practicable (ALARP) is both an ethical and legal requirement, falling under the Ionizing Radiation (medical exposure) regulations. There is a responsibility to reduce the long-term risks of radiation exposure (such as cancer reduction) to levels where the potential benefit of the examination outweighs the risk of any adverse effect. This is of particular importance in mammography, as the breast is a radiosensitive organ and mammography is currently the technique of choice for breast cancer screening, which results in a large number of disease-free women being imaged. </li> <li>Some digital mammographs are based on a different approach: instead of using a flat panel detector mammography part, a scanning slot imaging geometry is used. A fan beam x-ray mammography part and a line of detectors, mechanically scan the breasts to acquire the mammographic data. </li> </ol><br /> The mammographic system is integrated of a number of important mammography parts. The main mammographic parts are listed below:<br /> <br /> <ul> <li>The x-ray tube mammography part is the most important component of the system. It is responsible for the quality of the radiation.&nbsp; The target material (Mo, Mo/RH, Mo/W), the focal spots sized and the power of the tube are of prime importance.</li> <li>The x-ray filter type is also very important mammography part. It filters out the unnecessary components of the x-ray radiation, and improves the beam “quality”.</li> <li>The generator, as a mammography part, supplies the power to the x-ray tube. The generator should match the tube. </li> <li>Automatic exposure control system is a mammography part which automatically optimizes the electric parameters and sets the proper exposure. </li> <li>Compression pads are mammography parts of various sizes to match the size and the shape of various shapes and sizes of breasts. </li> <li>The full field digital detector (24 X 30cm) can be a very expensive mammography part. </li> <li>The image acquisition and reconstruction system is the mammography part which accesses the digital detector. It is capable of converting the digital data flow into high resolution images. </li> <li>The workstation is an important mammography part of the mammography system. </li> <li>The stereotactic biopsy attachment is the indispensable mammography part for taking biopsies of possibly abnormal tissue.</li> </ul><br />
Read more valuable tips on the Medical Equipment Buying Guide by MedWOW >>