Parts: Mammography Unit, Hologic
Applied Filters
Model
Continent
Condition
Manf. Year From
Manf. Year Until
Price Range (USD)
More Filters
![]() | Medical Part Finder | ![]() | Are you looking for a specific medical part, and you can't find it anywhere? We can find it for you, quickly and easily! | Go to Part Finder >> |
Please Note: Search results for this device do not include the following devices, please select the relevant device if it is of interest to you: Digital Mammography Unit
- Complete Systems (27)
- Parts (485)
Item Details
Seller details
Item Price (USD)
Year manufactured
Quick Look
Device: Mammography Unit
Manufacturer: Hologic
Model: Lorad
Name / Number: 4-000-0217
Manufacturer: Hologic
Model: Lorad
Name / Number: 4-000-0217
Premium User
Location: United States, Washington
Rating: 89%
Location: United States, Washington
Rating: 89%
105 
-
Quick Look
Device: Mammography Unit
Manufacturer: Hologic
Model: Lorad M-IV Series
Name / Number: BUCKY 18X24 HTC / 4-000-0241
Manufacturer: Hologic
Model: Lorad M-IV Series
Name / Number: BUCKY 18X24 HTC / 4-000-0241
Location: United States, Florida
3,323 
1999
Quick Look
Device: Mammography Unit
Manufacturer: Hologic
Model: M-IV Platinum
Name / Number: 18x24 bucky
Manufacturer: Hologic
Model: M-IV Platinum
Name / Number: 18x24 bucky
Location: Singapore
Negotiable
2003
Quick Look
Device: Mammography Unit
Manufacturer: Hologic
Model: M-IV
Name / Number: 40000242
Manufacturer: Hologic
Model: M-IV
Name / Number: 40000242
Location: Cyprus
1,450 
2006
Quick Look
Device: Mammography Unit
Manufacturer: Hologic
Model: M-III
Name / Number: ALARM PIEZO / 10810003
Manufacturer: Hologic
Model: M-III
Name / Number: ALARM PIEZO / 10810003
Location: United States, New York
Negotiable
-
Quick Look
Device: Mammography Unit
Manufacturer: Hologic
Model: M-III
Name / Number: CIRCUIT BOARD / 0108REV4
Manufacturer: Hologic
Model: M-III
Name / Number: CIRCUIT BOARD / 0108REV4
Location: United States, New York
Negotiable
-
Quick Look
Device: Mammography Unit
Manufacturer: Hologic
Model: M-III
Name / Number: UNSHEILDED CABLE / 10550042
Manufacturer: Hologic
Model: M-III
Name / Number: UNSHEILDED CABLE / 10550042
Location: United States, New York
Negotiable
-
Quick Look
Device: Mammography Unit
Manufacturer: Hologic
Model: M-III
Name / Number: TUBE CONTROL / 10010187
Manufacturer: Hologic
Model: M-III
Name / Number: TUBE CONTROL / 10010187
Location: United States, New York
Negotiable
-
Quick Look
Device: Mammography Unit
Manufacturer: Hologic
Model: M-III
Name / Number: SWITCH BOARD / 10010093
Manufacturer: Hologic
Model: M-III
Name / Number: SWITCH BOARD / 10010093
Location: United States, New York
Negotiable
-
Quick Look
Device: Mammography Unit
Manufacturer: Hologic
Model: M-III
Name / Number: POWER PANEL / 10010090
Manufacturer: Hologic
Model: M-III
Name / Number: POWER PANEL / 10010090
Location: United States, New York
Negotiable
-
Quick Look
Device: Mammography Unit
Manufacturer: Hologic
Model: M-III
Name / Number: MAG TRAY DETECT / 10010095
Manufacturer: Hologic
Model: M-III
Name / Number: MAG TRAY DETECT / 10010095
Location: United States, New York
Negotiable
-
Quick Look
Device: Mammography Unit
Manufacturer: Hologic
Model: M-III
Name / Number: KEYBOARD / 10010091
Manufacturer: Hologic
Model: M-III
Name / Number: KEYBOARD / 10010091
Location: United States, New York
Negotiable
-
Quick Look
Device: Mammography Unit
Manufacturer: Hologic
Model: M-III
Name / Number: AEC POSITION DETECTOR / 10010100
Manufacturer: Hologic
Model: M-III
Name / Number: AEC POSITION DETECTOR / 10010100
Location: United States, New York
Negotiable
-
Quick Look
Device: Mammography Unit
Manufacturer: Hologic
Model: M-III
Name / Number: ACCESSORY DETECT PCB / 10010106
Manufacturer: Hologic
Model: M-III
Name / Number: ACCESSORY DETECT PCB / 10010106
Location: United States, New York
Negotiable
-
Quick Look
Device: Mammography Unit
Manufacturer: Hologic
Model: M-III
Name / Number: 14 INCH MONITOR / 1096002610960039
Manufacturer: Hologic
Model: M-III
Name / Number: 14 INCH MONITOR / 1096002610960039
Location: United States, New York
Negotiable
-
The model & manufacturer of the marked items have changed due to an acquisition between companies, and are also known as:
| Current Manufacturer / Model Name | Alternative Manufacturer / Model Name |
|---|---|
| Lorad / M-IV | Hologic / M-IV |
| Lorad / M-III | Hologic / M-III |
| Lorad / M-IV Platinum | Hologic / M-IV Platinum |
Mammography Unit may also be referred to as :
Radiographic Unit, Mammographic | Xeromammograph | X-ray Mammography | System, X-ray, Mammography | Radiographic Unit, Mammography, Mobile | Mammography Unit | Mammograph | Mammographic Radiographic UnitTips for buying Mammography Unit Parts
Mammography x-ray systems are specially designed to produce radiographic images of the breast. This equipment is assembled of unique mammography parts, customized to produce the best images, with the minimal possible amount of exposure to x-ray radiation.<br /> <br /> The main clinical applications of these systems are: breast cancer screening, staging and grading, and differential diagnosis in symptomatic patients. <br /> <br /> <ol> <li>Most of the mammographs allow magnification views and spot images. In general, mammographs are composed of mammography parts which have special ergonomic requirements, compared to those of the general radiographic systems. </li> <li>A special stereotactic attachment, another critical mammography part, enables the performance of stereotactic biopsy procedures. </li> <li>The previous generation mammographs were all screen-film-types. A limitation of screen-film mammography is the film itself. Once a screen-field mammogram is obtained, it cannot be significantly altered. </li> <li>Contrast loss due to film underexposure, especially of dense glandular-tissues, cannot be regained through film display. </li> <li>The latest mammography equipment features special mammography parts which are integrated, and as a result, digital mammography images can be obtained. Now, when the mammograph is in a digital format, the image can be manipulated in a variety of ways to highlight lesion conspicuity. </li> <li>In addition, image storage, transmission and retrieval can be improved. Digital images can be processed by a computer mammography part and displayed in multiple formats; on film or on a monitor. Computer-aided detection software to assist the radiologist in interpreting the images can also be used to provide a second opinion and improve diagnostic accuracy.</li> <li>Digital mammography images can be obtained either by a full field of view (FFDM – full field digital mammography) a digital detector mammography part, or by using CR cassettes and a CR reader. Also, a small sized digital detector, another integral mammography part, can be incorporated into the film holder device mammography part, for image spotting and as a way of guiding stereotactic biopsies. </li> <li>Small field digital mammography units, are also available as add-on component mammography parts to the older screen-film mammographs. They can be used in conjunction with the mammography part stereotactic attachment. </li> <li>Digital imaging can be processed using sophisticated pattern recognition software, another vital mammography part, and “suspicious” features are highlighted on the image and brought to the attention of the reader. It is necessary to understand that the existing workflow will probably not work at a maximum efficiency once the department has moved to digital imaging. To achieve an efficient workflow, links to a PACS (Picture Archiving and Communications System) must be considered. </li> <li>Reducing patient dosage to levels which are as low as reasonably practicable (ALARP) is both an ethical and legal requirement, falling under the Ionizing Radiation (medical exposure) regulations. There is a responsibility to reduce the long-term risks of radiation exposure (such as cancer reduction) to levels where the potential benefit of the examination outweighs the risk of any adverse effect. This is of particular importance in mammography, as the breast is a radiosensitive organ and mammography is currently the technique of choice for breast cancer screening, which results in a large number of disease-free women being imaged. </li> <li>Some digital mammographs are based on a different approach: instead of using a flat panel detector mammography part, a scanning slot imaging geometry is used. A fan beam x-ray mammography part and a line of detectors, mechanically scan the breasts to acquire the mammographic data. </li> </ol><br /> The mammographic system is integrated of a number of important mammography parts. The main mammographic parts are listed below:<br /> <br /> <ul> <li>The x-ray tube mammography part is the most important component of the system. It is responsible for the quality of the radiation. The target material (Mo, Mo/RH, Mo/W), the focal spots sized and the power of the tube are of prime importance.</li> <li>The x-ray filter type is also very important mammography part. It filters out the unnecessary components of the x-ray radiation, and improves the beam “quality”.</li> <li>The generator, as a mammography part, supplies the power to the x-ray tube. The generator should match the tube. </li> <li>Automatic exposure control system is a mammography part which automatically optimizes the electric parameters and sets the proper exposure. </li> <li>Compression pads are mammography parts of various sizes to match the size and the shape of various shapes and sizes of breasts. </li> <li>The full field digital detector (24 X 30cm) can be a very expensive mammography part. </li> <li>The image acquisition and reconstruction system is the mammography part which accesses the digital detector. It is capable of converting the digital data flow into high resolution images. </li> <li>The workstation is an important mammography part of the mammography system. </li> <li>The stereotactic biopsy attachment is the indispensable mammography part for taking biopsies of possibly abnormal tissue.</li> </ul><br />Read more valuable tips on the Medical Equipment Buying Guide by MedWOW >>












