New & Used Pacemaker

Market Value Calculator
 
Manf. Year From
Manf. Year Until
More Filters
 
 
 
 
Item Details
Seller details
Item Price (USD)
Year manufactured

Quick Look

 
Device: Pacemaker
Manufacturer: Universal Medical
Model: Pacetrak Plus
Premium User
Location: United States, Washington
Business type: Dealer
Rating: 89%
155
This Seller accepts Escrow as a payment method
-

Quick Look

 
Device: Pacemaker
Manufacturer: Universal Medical
Model: Pacetrak Plus
Premium User
Location: United States, Washington
Business type: Dealer
Rating: 89%
155
This Seller accepts Escrow as a payment method
-

Quick Look

 
Device: Pacemaker Tester
Manufacturer: Telectronics
Model: Pacing System 9600
Location: United States, Minnesota
Business type: Dealer
Rating: 80%
Negotiable
This Seller accepts Escrow as a payment method
-

Quick Look

 
Device: Pacemaker Tester
Manufacturer: Telectronics
Model: Pacing System 9600
Location: United States, Minnesota
Business type: Dealer
Rating: 80%
Negotiable
This Seller accepts Escrow as a payment method
-

Quick Look

 
Device: Pacemaker Tester
Manufacturer: Telectronics
Model: Pacing System 9600
Location: United States, Minnesota
Business type: Dealer
Rating: 80%
Negotiable
This Seller accepts Escrow as a payment method
-

Quick Look

 
Device: Pacemaker Tester
Manufacturer: Telectronics
Model: Pacing System 9600
Location: United States, Minnesota
Business type: Dealer
Rating: 80%
Negotiable
This Seller accepts Escrow as a payment method
-

Quick Look

 
Device: Pacemaker Tester
Manufacturer: Telectronics
Model: Pacing System 9600
Location: United States, Minnesota
Business type: Dealer
Rating: 80%
Negotiable
This Seller accepts Escrow as a payment method
-

Quick Look

 
Device: Pacemaker
Manufacturer: Intermedics
Model: RX5000
Location: United States, New York
Rating: 77%
1,300
2005

Quick Look

 
Device: Pacemaker
Manufacturer: Universal Medical
Model: Pacetrak Plus
Location: United States, Wisconsin
100
-

Quick Look

 
Device: Pacemaker
Manufacturer: CORDIS
Model: Chronocor IV 250B
Location: United States, New York
Rating: 77%
550
2007

Quick Look

 
Device: Pacemaker
Manufacturer: Telectronics
Model: Pacing System 9600
Location: United States, New York
Rating: 77%
1,300
2005

Quick Look

 
Device: Pacemaker
Manufacturer: Instrumedics
Model: CardioChek 5060-05
Location: United States, New York
Rating: 77%
400
2007

Quick Look

 
Device: Pacemaker
Manufacturer: Intermedics
Model: RX5000
Location: United States, Minnesota
Business type: Dealer
Rating: 93%
Negotiable
-

Quick Look

 
Device: Pacemaker
Manufacturer: Intermedics
Model: RX5000
Location: United States, New York
Rating: 77%
Negotiable
This Seller accepts Escrow as a payment method
-

Quick Look

 
Device: Pacemaker
Manufacturer: Intermedics
Model: RX5000
Location: United States, New York
Rating: 77%
Negotiable
This Seller accepts Escrow as a payment method
-
Page: 1 2

Pacemaker may also be referred to as :

Pacemaker, Cardiac, Internal | Pacemaker. Implantable | Internal Pacemaker | Cardiac Pacemaker | Pacemaker, Cardiac, Implantable

Didn't find the medical device you're looking for? Post a Buying Request
A buying lead is an excellent way to reach worldwide medical equipment sellers!
  • Fill in a simple form, giving us details about the medical device you are searching for.
  • Receive competitive quotes from global sellers that have the item you are searching for in their inventory.
  • Choose the best and most suitable quote for you!
Post a Buying Request >>
 

Tips for buying Pacemaker

  1. Physicians are in the best position to decide on the pacemaker specifications, based on patient illness and specific requirements. Different patients need pacemakers with different operating modes, levels of adjustability, and other capabilities. In the selection process, facilities should include cardiologists, cardiovascular surgeons, and electro physiologists.
  2. A hermetically sealed pulse generator and either one or two insulated conductive leads should be in each implantable pacemaker, as well as a programmable mode, rate, sensitivity, pulse width, and amplitude.
  3. Pulse generators should be compatible with IS-1/VS-1 leads or encountered lead connectors.
  4. These implantable pacemakers display four available categories. The pacing modes common to each are listed in brackets. Many manufacturers offer at least one model of each of these four types of cardiac pacemakers:
  • ·  Multiprogrammable, single chamber (VVI, AAI, VOO)
  • ·  Multiprogrammable, single chamber with rate modulation (VVIR)
  • ·  Multiprogrammable, dual chamber (DDD)
  • ·  Multiprogrammable, dual chamber with rate modulation (DDDR)
  1. Suppliers should offer each type of pacemaker with either a unipolar or bipolar lead configuration. All units should be capable of transmitting patient information and the pacemaker's operating parameters to the programmer. These transmittable parameters may include: programmed settings, battery status, lead impedance, identification number, model number, serial number, and measurements of pacing rate, pulse amplitude, and pulse width.
  2. Each cardiac pacemaker unit should operate for at least five years at 100% pacing, and should include a low battery indicator.
  3. All leads should be pre-sterilized and double packaged in hermetically sealed individual containers. These packages should be clearly labeled with the following information: manufacturer, model, serial number, expiration date, connector type and size, and tip electrode type.
  4. The expiration date on the leads should not be less than one year from the delivery date.
  5. These are the main factors to consider when selecting a pacemaker: technology, service issues, and reliability.