Device: Peritoneal Dialysis Unit
Manufacturer: Baxter
Model: HomeChoice
Location: United Kingdom, Greater London
3,000
This Seller accepts SafeTrade as a payment method
-

Peritoneal Dialysis Unit may also be referred to as :

Peritoneal Therapy Unit | Peritoneal Dialysis Machine | Peritoneal Dialysis Drainage System | Peritoneal Dialysis Cyclers | Kidney Machine | Dialysis Unit | Cyclers, Peritoneal Dialysis | Artificial Kidney Machine
 

Tips for buying Peritoneal Dialysis Unit

  1. Safeguards such as a low-drain alarm and a fluid-retention alarm should be in place to prevent overfilling a patient's peritoneum with dialysate. When less than a set percent of the infused dialysate volume is drained from the patient after each drain cycle, the low drain alarm should be set.
  2. It is important to prevent overfilling because besides discomfort from the intra-abdominal pressure, it can cause serious complications, such as decreased pulmonary function, and decreased cardiac performance, periatherter leakage, and hernia.
  3. The low drain alarm should be set to a point between 60% and 85%. A fluid retention alarm is generated by the ultra filtration monitor and activates in case of a significant discrepancy between the dialysate-fill volume and the drain volume.
  4. If the patient cumulatively retains over one half of the fill volume setting, it is recommended that the fluid retention alarm go off.
  5. Facilities should carefully consider the dialysate temperature. It must be warm enough so that the patient is comfortable, and cool enough not to damage the peritoneum. Warm dialysate increases patient comfort by avoiding body cooling and is also thought to increase the effectiveness of dialysis by causing vasodilatation and increased diffusion.
  6. The patient should be protected from receiving cold dialysate fluid by disallowing dialysate infusion until it is warmed. If the dialysate enters the patient when it's too warm, it can cause peritoneal sclerosis. If the unit starts to deliver dialysate over 43°C, audible and visual alarms are recommended, an interruption of power to the heater, as well as a cessation of dialysis flow to the patient.
  7. Other alarms are recommended to alert users to the disruption of dialysis to the patient. The unit should also alarm upon power failure or an insufficient volume of dialysate delivered to the patient.
  8. In units used at home, reliability is a special concern. No backup unit or repair technician is usually available at home, and if the unit ceases to function in the middle of a treatment, the consequences can be serious.
  9. In homes, power, water pressure, and temperature may not be regulated as well as in medical facilities; therefore, limited acceptable ranges of supply voltage and water temperature become important issues in selecting a unit.