Device: Rad Room, Digital
Manufacturer: Siemens
Model: VERTIX 3D3
Name / Number: 8450819
Location: Netherlands, Overijssel
Business type: Exporter
Negotiable
-

Quick Look

 
Device: Rad Room, Digital
Manufacturer: Siemens
Model: VERTIX 3D3
Name / Number: 8763716
Location: Netherlands, Overijssel
Business type: Exporter
Negotiable
-

Quick Look

 
Device: Rad Room, Digital
Manufacturer: Siemens
Model: VERTIX 3D3
Name / Number: 8772816
Location: Netherlands, Overijssel
Business type: Exporter
Negotiable
-
Page: 1 2 3 4 5

Rad/Fluoro Room, Flat Panel may also be referred to as :

Radiographic/Fluoroscopic Table System, FP | Digital RF Equipment | Radiographic/Fluoroscopic Table System, Flat Panel

If you have not found your required medical part at the list above, our suppliers can offer you the following medical parts (21):

 
Item Details
Actions
46-174804 46174804

Device: Rad/Fluoro Room, Flat Panel

Manufacturer: GE Healthcare

Model: Precision MPi

Name / Number: 46-174804 / 46174804

Image intencifier 9" 9896 010 01211

Device: Rad/Fluoro Room, Flat Panel

Manufacturer: Philips

Model: MultiDiagnost Eleva II-TV

Name / Number: Image intencifier 9" / 9896 010 01211

Image Intensifier 15" 9896 010 01041

Device: Rad/Fluoro Room, Flat Panel

Manufacturer: Philips

Model: MultiDiagnost Eleva II-TV

Name / Number: Image Intensifier 15" / 9896 010 01041

Image Intensifier 9" 9807 200 43701

Device: Rad/Fluoro Room, Flat Panel

Manufacturer: Philips

Model: MultiDiagnost Eleva II-TV

Name / Number: Image Intensifier 9" / 9807 200 43701

Image Intensifier PS PS9896-010

Device: Rad/Fluoro Room, Flat Panel

Manufacturer: Philips

Model: MultiDiagnost Eleva II-TV

Name / Number: Image Intensifier PS / PS9896-010

Image Intensifier PS 1654529-X-2134

Device: Rad/Fluoro Room, Flat Panel

Manufacturer: Siemens

Model: AXIOM SIRESKOP SD

Name / Number: Image Intensifier PS / 1654529-X-2134

Image Intensifier PS 38-29-103-X2181

Device: Rad/Fluoro Room, Flat Panel

Manufacturer: Siemens

Model: AXIOM SIRESKOP SD

Name / Number: Image Intensifier PS / 38-29-103-X2181

Intensifier 40-4HDR 40-4HDR

Device: Rad/Fluoro Room, Flat Panel

Manufacturer: Siemens

Model: AXIOM SIRESKOP SD

Name / Number: Intensifier 40-4HDR / 40-4HDR

Newvicon S-4076 S-4076

Device: Rad/Fluoro Room, Flat Panel

Manufacturer: Siemens

Model: AXIOM SIRESKOP SD

Name / Number: Newvicon S-4076 / S-4076

Newvicon XQ1440X XQ1440X

Device: Rad/Fluoro Room, Flat Panel

Manufacturer: Siemens

Model: AXIOM Luminos dRF

Name / Number: Newvicon XQ1440X / XQ1440X

Page: 1 2 3

Didn't find the medical device you're looking for? Post a Buying Request
A buying lead is an excellent way to reach worldwide medical equipment sellers!
  • Fill in a simple form, giving us details about the medical device you are searching for.
  • Receive competitive quotes from global sellers that have the item you are searching for in their inventory.
  • Choose the best and most suitable quote for you!
Post a Buying Request >>
 

Tips for buying Rad/Fluoro Room, Flat Panel Parts

  1. Storage space reduction, enhanced image processing, and off-site diagnostic capabilities are some of the advantages of digital radiography (flat panel fluoro rooms/flat panel rad rooms) over film-based radiography.
  2. The tilting tables allow a wide range of tilting movements from -15° to +90° and have an average speed of 6°/sec. Horizontal-to-vertical tilt should average 15 sec.
  3. The non-tilting tables specify a wide range of tabletop motions but do not allow tilting angles.
  4. Digital radiographic systems generally perform upright examinations or table-based examinations, for which detector mounting is crucial.
  5. The detector is fixed in the table system in table-based units, preventing certain examinations due to patient positioning constraints. Some upright systems can be tilted to allow table based exams.
  6. Facilities should evaluate all types of examinations being performed before deciding which type will better suit their needs. The number and types of procedures will influence the features selected for the system.
  7. Smaller focal-spot sizes can provide better spatial resolution on film for certain studies, and options such as tomography and table tilt can increase the system’s overall procedural capabilities.
  8. Departments handling trauma and emergency cases may prefer elevating tables because the table height can be adjusted to facilitate patient transfer from a mobile stretcher or a wheelchair.
  9. Bucky systems for both tilting and non-tilting tables should be motorized.
  10. To ensure acceptable film darkening, a three-field AEC device is recommended. Grid ratios should be 10:1 or higher. Grids with higher ratios provide higher image quality.
  11. Buyers of flat panel fluoro rooms/flat panel rad rooms should look into the fluoroscopic table system’s integration into picture archiving and communication systems (PACS) already in use in the facility.
  12. Buyers of digital RF equipment should consider generator options as well. High-frequency generators need less space and often eliminate the need for high-voltage cables.
  13. To facilitate future additions to any flat panel fluoro room/flat panel rad room network, compatibility with DICOM 3.0 is a requirement for all newly purchased equipment (including storage devices).
  14. Suppliers must provide DICOM conformance statements that explain in detail which information objects, service classes, and data encodings are supported by the system. The statements should be inspected by specialists, and should share the same format and vocabulary to facilitate comparisons between suppliers.