New & Used Rad/Fluoro Room, Image Intensifier, Siemens

Market Value Calculator
 
Applied Filters

Manufacturer : Siemens

  Reset
More Filters
Please Note: Search results for this device do not include the following devices, please select the relevant device if it is of interest to you: C-Arm,Rad/Fluoro Room, Flat Panel,Cath Lab
 
 
 
 
Item Details
Seller details
Item Price (USD)
Year manufactured

Quick Look

 
Device: Rad/Fluoro Room, Image Intensifier
Manufacturer: Siemens
Model: SIRESKOP SX
Premium User
Location: United States, Washington
Rating: 89%
13,520
-

Quick Look

 
Device: Rad/Fluoro Room, Image Intensifier
Manufacturer: Siemens
Model: SIRESKOP 5
Location: Bulgaria, Sofyia
20,151
1998

Quick Look

 
Device: Rad/Fluoro Room, Image Intensifier
Manufacturer: Siemens
Model: SIRESKOP 5
Location: United States, Illinois
5,000
1991

Quick Look

 
Device: Rad/Fluoro Room, Image Intensifier
Manufacturer: Siemens
Model: SIREGRAPH TOP 40
Location: Turkey, Istanbul
21,231
2004

Quick Look

 
Device: Rad/Fluoro Room, Image Intensifier
Manufacturer: Siemens
Model: SIRESKOP SX
Location: United States, Ohio
Rating: 100%
75,000
This Seller accepts SafeTrade as a payment method
-

Quick Look

 
Device: Rad/Fluoro Room, Image Intensifier
Manufacturer: Siemens
Model: AXIOM Luminos RF
Location: France, Île-de-France
1,746
2009

Quick Look

 
Device: Rad/Fluoro Room, Image Intensifier
Manufacturer: Siemens
Model: SIRESKOP SX
Location: France, Île-de-France
24,181
This Seller accepts SafeTrade as a payment method
2002

Quick Look

 
Device: Rad/Fluoro Room, Image Intensifier
Manufacturer: Siemens
Model: AXIOM Iconos R200
Location: Turkey, Istanbul
59,446
2004

Quick Look

 
Device: Rad/Fluoro Room, Image Intensifier
Manufacturer: Siemens
Model: SIRESKOP SD
Location: United States, Alabama
25,000
2002

Quick Look

 
Device: Rad/Fluoro Room, Image Intensifier
Manufacturer: Siemens
Model: SIRESKOP SD
Location: United States, New Jersey
Negotiable
2005

Quick Look

 
Device: Rad/Fluoro Room, Image Intensifier
Manufacturer: Siemens
Model: SIRESKOP SD
Location: United States, New Jersey
Negotiable
2001
Page: 1 2

Rad/Fluoro Room, Image Intensifier may also be referred to as :

Non Digital R/F Equipment | Radiographic/Fluoroscopic Table System, Image Intensifier
 

Tips for buying Rad/Fluoro Room, Image Intensifier

  1. Storage space reduction, enhanced image processing, and off-site diagnostic capabilities are some of the advantages of digital radiography over film-based radiography. Image intensifiers increase the intensity of available light in an optical system to allow use under low light conditions such as at night, to facilitate visual imaging of low-light processes such as fluorescence of materials to x-rays or gamma rays, or for conversion of non-visible light sources such as near-infrared or short wave infrared to visible.
  2. The tilting tables allow a wide range of tilting movements from -15° to +90° and have an average speed of 6°/sec. Horizontal-to-vertical tilt should average 15 sec.
  3. The non-tilting tables specify a wide range of tabletop motions but do not allow tilting angles.
  4. Digital radiographic systems generally perform upright examinations or table-based examinations, for which detector mounting is crucial.
  5. The detector is fixed in the table system in table-based units, preventing certain examinations due to patient positioning constraints. Some upright systems can be tilted to allow table based exams.
  6. Facilities should evaluate all types of examinations being performed before deciding which type of image intensifier will better suit their needs. The number and types of procedures will influence the features selected for the system.
  7. Smaller focal-spot sizes can provide better spatial resolution on film for certain studies, and options such as tomography and table tilt can increase the image intensifier system’s overall procedural capabilities.
  8. Departments handling trauma and emergency cases may prefer elevating tables because the table height can be adjusted to facilitate patient transfer from a mobile stretcher or a wheelchair.
  9. Bucky systems for both tilting and non-tilting tables should be motorized.
  10. To ensure acceptable film darkening, a three-field AEC device is recommended. Grid ratios should be 10:1 or higher. Grids with higher ratios provide higher image quality.
  11. Buyers should look into the image intensifier system’s integration into picture archiving and communication systems (PACS) already in use in the facility.
  12. Buyers should consider generator options as well; high-frequency generators need less space and often eliminate the need for high-voltage cables.
  13. To facilitate future additions to any network, compatibility with DICOM 3.0 is a requirement for all newly purchased equipment (including storage devices).
  14. Suppliers must provide DICOM conformance statements that explain in detail which information objects, service classes, and data encodings are supported by the system. The statements should be inspected by specialists, and should share the same format and vocabulary to facilitate comparisons between suppliers.
Read more valuable tips on the Medical Equipment Buying Guide by MedWOW >>